CWE-284

Improper Access Control

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

CVE-2021-25447 (GCVE-0-2021-25447)

Vulnerability from cvelistv5 – Published: 2021-08-05 19:43 – Updated: 2024-08-03 20:03
VLAI
Summary
Improper access control vulnerability in SmartThings prior to version 1.7.67.25 allows untrusted applications to cause local file inclusion in webview.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Samsung Mobile Smart Things Affected: - , < 1.7.67.25 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:03:05.760Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=8"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smart Things",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "1.7.67.25",
              "status": "affected",
              "version": "-",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper access control vulnerability in SmartThings prior to version 1.7.67.25 allows untrusted applications to cause local file inclusion in webview."
        }
      ],
      "metrics": [
        {
          "other": {
            "content": {
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N"
            },
            "type": "unknown"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-05T19:43:56.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=8"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2021-25447",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smart Things",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "-",
                            "version_value": "1.7.67.25"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper access control vulnerability in SmartThings prior to version 1.7.67.25 allows untrusted applications to cause local file inclusion in webview."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=8",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=8"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2021-25447",
    "datePublished": "2021-08-05T19:43:56.000Z",
    "dateReserved": "2021-01-19T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:03:05.760Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25448 (GCVE-0-2021-25448)

Vulnerability from cvelistv5 – Published: 2021-08-05 19:44 – Updated: 2024-08-03 20:03
VLAI
Summary
Improper access control vulnerability in Smart Touch Call prior to version 1.0.0.5 allows arbitrary webpage loading in webview.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Samsung Mobile Smart Touch Call Affected: - , < 1.0.0.5 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:03:05.665Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=8"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smart Touch Call",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "1.0.0.5",
              "status": "affected",
              "version": "-",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper access control vulnerability in Smart Touch Call prior to version 1.0.0.5 allows arbitrary webpage loading in webview."
        }
      ],
      "metrics": [
        {
          "other": {
            "content": {
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N"
            },
            "type": "unknown"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-05T19:44:02.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=8"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2021-25448",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smart Touch Call",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "-",
                            "version_value": "1.0.0.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper access control vulnerability in Smart Touch Call prior to version 1.0.0.5 allows arbitrary webpage loading in webview."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=8",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=8"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2021-25448",
    "datePublished": "2021-08-05T19:44:02.000Z",
    "dateReserved": "2021-01-19T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:03:05.665Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25463 (GCVE-0-2021-25463)

Vulnerability from cvelistv5 – Published: 2021-09-09 18:05 – Updated: 2024-08-03 20:03
VLAI
Summary
Improper access control vulnerability in PENUP prior to version 3.8.00.18 allows arbitrary webpage loading in webview.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Samsung Mobile PENUP Affected: - , < 3.8.00.18 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:03:05.615Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=9"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PENUP",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "3.8.00.18",
              "status": "affected",
              "version": "-",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper access control vulnerability in PENUP prior to version 3.8.00.18 allows arbitrary webpage loading in webview."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-09T18:05:14.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=9"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2021-25463",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PENUP",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "-",
                            "version_value": "3.8.00.18"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper access control vulnerability in PENUP prior to version 3.8.00.18 allows arbitrary webpage loading in webview."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=9",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2021\u0026month=9"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2021-25463",
    "datePublished": "2021-09-09T18:05:14.000Z",
    "dateReserved": "2021-01-19T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:03:05.615Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25501 (GCVE-0-2021-25501)

Vulnerability from cvelistv5 – Published: 2021-11-05 02:03 – Updated: 2024-08-03 20:03
VLAI
Summary
An improper access control vulnerability in SCloudBnRReceiver in SecTelephonyProvider prior to SMR Nov-2021 Release 1 allows untrusted application to call some protected providers.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Samsung Mobile Samsung Mobile Devices Affected: Q(10.0), R(11.0) , < SMR Nov-2021 Release 1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:03:05.587Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2021\u0026month=11"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Samsung Mobile Devices",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "SMR Nov-2021 Release 1",
              "status": "affected",
              "version": "Q(10.0), R(11.0)",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An improper access control vulnerability in SCloudBnRReceiver in SecTelephonyProvider prior to SMR Nov-2021 Release 1 allows untrusted application to call some protected providers."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-05T02:03:26.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2021\u0026month=11"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2021-25501",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Samsung Mobile Devices",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Q(10.0), R(11.0)",
                            "version_value": "SMR Nov-2021 Release 1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An improper access control vulnerability in SCloudBnRReceiver in SecTelephonyProvider prior to SMR Nov-2021 Release 1 allows untrusted application to call some protected providers."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/securityUpdate.smsb?year=2021\u0026month=11",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2021\u0026month=11"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2021-25501",
    "datePublished": "2021-11-05T02:03:26.000Z",
    "dateReserved": "2021-01-19T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:03:05.587Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25672 (GCVE-0-2021-25672)

Vulnerability from cvelistv5 – Published: 2021-03-15 17:03 – Updated: 2024-08-03 20:11
VLAI
Summary
A vulnerability has been identified in Mendix Forgot Password Appstore module (All Versions < V3.2.1). The Forgot Password Marketplace module does not properly control access. An attacker could take over accounts.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:11:27.709Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917115.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Forgot Password Appstore module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Forgot Password Appstore module (All Versions \u003c V3.2.1). The Forgot Password Marketplace module does not properly control access. An attacker could take over accounts."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-03-15T17:03:31.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917115.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-25672",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Forgot Password Appstore module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All Versions \u003c V3.2.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Forgot Password Appstore module (All Versions \u003c V3.2.1). The Forgot Password Marketplace module does not properly control access. An attacker could take over accounts."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-917115.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917115.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-25672",
    "datePublished": "2021-03-15T17:03:31.000Z",
    "dateReserved": "2021-01-21T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:11:27.709Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25749 (GCVE-0-2021-25749)

Vulnerability from cvelistv5 – Published: 2023-05-24 00:00 – Updated: 2025-01-16 21:21
VLAI
Title
runAsNonRoot logic bypass for Windows containers
Summary
Windows workloads can run as ContainerAdministrator even when those workloads set the runAsNonRoot option to true.
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Vendor Product Version
Kubernetes Kubernetes Affected: kubelet v1.22.0 - v1.22.13 , < v1.22.14 (custom)
Affected: kubelet v1.23.0 - v1.23.10 , < v1.23.11 (custom)
Affected: kubelet v1.24.0 - v1.24.4 , < v1.24.5 (custom)
Create a notification for this product.
Date Public
2022-09-15 00:00
Credits
Mark Rosetti (@marosset) of Microsoft
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:11:27.842Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://groups.google.com/g/kubernetes-security-announce/c/qqTZgulISzA"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-25749",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T21:21:04.984374Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:21:12.621Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Kubernetes",
          "vendor": "Kubernetes",
          "versions": [
            {
              "lessThan": "v1.22.14",
              "status": "affected",
              "version": "kubelet v1.22.0 - v1.22.13",
              "versionType": "custom"
            },
            {
              "lessThan": "v1.23.11",
              "status": "affected",
              "version": "kubelet v1.23.0 - v1.23.10",
              "versionType": "custom"
            },
            {
              "lessThan": "v1.24.5",
              "status": "affected",
              "version": "kubelet v1.24.0 - v1.24.4",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Mark Rosetti (@marosset) of Microsoft"
        }
      ],
      "datePublic": "2022-09-15T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Windows workloads can run as ContainerAdministrator even when those workloads set the runAsNonRoot option to true."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-24T00:00:00.000Z",
        "orgId": "a6081bf6-c852-4425-ad4f-a67919267565",
        "shortName": "kubernetes"
      },
      "references": [
        {
          "url": "https://groups.google.com/g/kubernetes-security-announce/c/qqTZgulISzA"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "To mitigate these vulnerabilities, upgrade Kubernetes: https://kubernetes.io/docs/tasks/administer-cluster/cluster-management/#upgrading-a-cluster"
        }
      ],
      "source": {
        "defect": [
          "https://github.com/kubernetes/kubernetes/issues/112192"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "runAsNonRoot logic bypass for Windows containers",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6081bf6-c852-4425-ad4f-a67919267565",
    "assignerShortName": "kubernetes",
    "cveId": "CVE-2021-25749",
    "datePublished": "2023-05-24T00:00:00.000Z",
    "dateReserved": "2021-01-21T00:00:00.000Z",
    "dateUpdated": "2025-01-16T21:21:12.621Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25954 (GCVE-0-2021-25954)

Vulnerability from cvelistv5 – Published: 2021-08-09 16:58 – Updated: 2024-09-17 00:31
VLAI
Title
Improper Access Control in “Dolibarr”
Summary
In “Dolibarr” application, 2.8.1 to 13.0.4 don’t restrict or incorrectly restricts access to a resource from an unauthorized actor. A low privileged attacker can modify the Private Note which only an administrator has rights to do, the affected field is at “/adherents/note.php?id=1” endpoint.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Dolibarr dolibarr Affected: 2.8.1 , < unspecified (custom)
Affected: unspecified , ≤ 13.0.4 (custom)
Create a notification for this product.
Date Public
2021-08-06 00:00
Credits
Hagai Wechsler
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:19:18.981Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25954"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Dolibarr/dolibarr/commit/8cc100012d46282799fb19f735a53b7101569377"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "dolibarr",
          "vendor": "Dolibarr",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "2.8.1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "13.0.4",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Hagai Wechsler"
        }
      ],
      "datePublic": "2021-08-06T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In \u201cDolibarr\u201d application, 2.8.1 to 13.0.4 don\u2019t restrict or incorrectly restricts access to a resource from an unauthorized actor. A low privileged attacker can modify the Private Note which only an administrator has rights to do, the affected field is at \u201c/adherents/note.php?id=1\u201d endpoint."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-09T16:58:31.000Z",
        "orgId": "478c68dd-22c1-4a41-97cd-654224dfacff",
        "shortName": "Mend"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25954"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Dolibarr/dolibarr/commit/8cc100012d46282799fb19f735a53b7101569377"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update to 14.0.0"
        }
      ],
      "source": {
        "advisory": "https://www.whitesourcesoftware.com/vulnerability-database/",
        "discovery": "UNKNOWN"
      },
      "title": "Improper Access Control in \u201cDolibarr\u201d",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnerabilitylab@whitesourcesoftware.com",
          "DATE_PUBLIC": "2021-08-06T21:00:00.000Z",
          "ID": "CVE-2021-25954",
          "STATE": "PUBLIC",
          "TITLE": "Improper Access Control in \u201cDolibarr\u201d"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "dolibarr",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_value": "2.8.1"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_value": "13.0.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dolibarr"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Hagai Wechsler"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In \u201cDolibarr\u201d application, 2.8.1 to 13.0.4 don\u2019t restrict or incorrectly restricts access to a resource from an unauthorized actor. A low privileged attacker can modify the Private Note which only an administrator has rights to do, the affected field is at \u201c/adherents/note.php?id=1\u201d endpoint."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25954",
              "refsource": "MISC",
              "url": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25954"
            },
            {
              "name": "https://github.com/Dolibarr/dolibarr/commit/8cc100012d46282799fb19f735a53b7101569377",
              "refsource": "MISC",
              "url": "https://github.com/Dolibarr/dolibarr/commit/8cc100012d46282799fb19f735a53b7101569377"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update to 14.0.0"
          }
        ],
        "source": {
          "advisory": "https://www.whitesourcesoftware.com/vulnerability-database/",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "478c68dd-22c1-4a41-97cd-654224dfacff",
    "assignerShortName": "Mend",
    "cveId": "CVE-2021-25954",
    "datePublished": "2021-08-09T16:58:31.962Z",
    "dateReserved": "2021-01-22T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:31:24.945Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25956 (GCVE-0-2021-25956)

Vulnerability from cvelistv5 – Published: 2021-08-17 14:15 – Updated: 2024-09-16 19:45
VLAI
Title
Improper User Access Control in "Dolibarr" Leads to Account Takeover
Summary
In “Dolibarr” application, v3.3.beta1_20121221 to v13.0.2 have “Modify” access for admin level users to change other user’s details but fails to validate already existing “Login” name, while renaming the user “Login”. This leads to complete account takeover of the victim user. This happens since the password gets overwritten for the victim user having a similar login name.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Dolibarr dolibarr Affected: 3.3.beta1_20121221 , < * (custom)
Create a notification for this product.
Date Public
2021-08-11 00:00
Credits
Daniel Elkabes
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:19:18.970Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Dolibarr/dolibarr/commit/c4cba43bade736ab89e31013a6ccee59a6e077ee"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25956"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "dolibarr",
          "vendor": "Dolibarr",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "3.3.beta1_20121221",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Daniel Elkabes"
        }
      ],
      "datePublic": "2021-08-11T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In \u201cDolibarr\u201d application, v3.3.beta1_20121221 to v13.0.2 have \u201cModify\u201d access for admin level users to change other user\u2019s details but fails to validate already existing \u201cLogin\u201d name, while renaming the user \u201cLogin\u201d. This leads to complete account takeover of the victim user. This happens since the password gets overwritten for the victim user having a similar login name."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-17T14:15:54.000Z",
        "orgId": "478c68dd-22c1-4a41-97cd-654224dfacff",
        "shortName": "Mend"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Dolibarr/dolibarr/commit/c4cba43bade736ab89e31013a6ccee59a6e077ee"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25956"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update to 14.0.0"
        }
      ],
      "source": {
        "advisory": "https://www.whitesourcesoftware.com/vulnerability-database/",
        "discovery": "UNKNOWN"
      },
      "title": "Improper User Access Control in \"Dolibarr\" Leads to Account Takeover",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "vulnerabilitylab@whitesourcesoftware.com",
          "DATE_PUBLIC": "2021-08-11T09:00:00.000Z",
          "ID": "CVE-2021-25956",
          "STATE": "PUBLIC",
          "TITLE": "Improper User Access Control in \"Dolibarr\" Leads to Account Takeover"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "dolibarr",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "\u003e=",
                            "version_name": "",
                            "version_value": "3.3.beta1_20121221"
                          },
                          {
                            "platform": "",
                            "version_affected": "\u003c=",
                            "version_name": "",
                            "version_value": "13.0.2 +1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dolibarr"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [
          {
            "lang": "eng",
            "value": "Daniel Elkabes"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In \u201cDolibarr\u201d application, v3.3.beta1_20121221 to v13.0.2 have \u201cModify\u201d access for admin level users to change other user\u2019s details but fails to validate already existing \u201cLogin\u201d name, while renaming the user \u201cLogin\u201d. This leads to complete account takeover of the victim user. This happens since the password gets overwritten for the victim user having a similar login name."
            }
          ]
        },
        "exploit": [],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/Dolibarr/dolibarr/commit/c4cba43bade736ab89e31013a6ccee59a6e077ee",
              "refsource": "MISC",
              "url": "https://github.com/Dolibarr/dolibarr/commit/c4cba43bade736ab89e31013a6ccee59a6e077ee"
            },
            {
              "name": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25956",
              "refsource": "MISC",
              "url": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25956"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update to 14.0.0"
          }
        ],
        "source": {
          "advisory": "https://www.whitesourcesoftware.com/vulnerability-database/",
          "defect": [],
          "discovery": "UNKNOWN"
        },
        "work_around": []
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "478c68dd-22c1-4a41-97cd-654224dfacff",
    "assignerShortName": "Mend",
    "cveId": "CVE-2021-25956",
    "datePublished": "2021-08-17T14:15:54.142Z",
    "dateReserved": "2021-01-22T00:00:00.000Z",
    "dateUpdated": "2024-09-16T19:45:46.350Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25991 (GCVE-0-2021-25991)

Vulnerability from cvelistv5 – Published: 2021-12-29 09:10 – Updated: 2025-04-30 15:43
VLAI
Title
ifme - Improper Access Control leads to admin deactivation
Summary
In Ifme, versions v5.0.0 to v7.32 are vulnerable against an improper access control, which makes it possible for admins to ban themselves leading to their deactivation from Ifme account and complete loss of admin access to Ifme.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
ifmeorg ifme Affected: v5.0.0 , < unspecified (custom)
Affected: unspecified , ≤ v7.32 (custom)
Create a notification for this product.
Date Public
2021-12-27 00:00
Credits
WhiteSource Vulnerability Research Team (WVR)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:19:19.411Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ifmeorg/ifme/commit/d1f570c458d41667df801fc9c40a18b181a2d923"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25991"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-25991",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-30T15:27:29.587587Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-30T15:43:44.984Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ifme",
          "vendor": "ifmeorg",
          "versions": [
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "v5.0.0",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "v7.32",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "WhiteSource Vulnerability Research Team (WVR)"
        }
      ],
      "datePublic": "2021-12-27T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Ifme, versions v5.0.0 to v7.32 are vulnerable against an improper access control, which makes it possible for admins to ban themselves leading to their deactivation from Ifme account and complete loss of admin access to Ifme."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-29T18:24:22.000Z",
        "orgId": "478c68dd-22c1-4a41-97cd-654224dfacff",
        "shortName": "Mend"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ifmeorg/ifme/commit/d1f570c458d41667df801fc9c40a18b181a2d923"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25991"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update version to v7.32.1 or later"
        }
      ],
      "source": {
        "advisory": "https://www.whitesourcesoftware.com/vulnerability-database/",
        "discovery": "UNKNOWN"
      },
      "title": "ifme - Improper Access Control leads to admin deactivation",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnerabilitylab@whitesourcesoftware.com",
          "DATE_PUBLIC": "2021-12-27T08:22:00.000Z",
          "ID": "CVE-2021-25991",
          "STATE": "PUBLIC",
          "TITLE": "ifme - Improper Access Control leads to admin deactivation"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ifme",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e=",
                            "version_value": "v5.0.0"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_value": "v7.32"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ifmeorg"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "WhiteSource Vulnerability Research Team (WVR)"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Ifme, versions v5.0.0 to v7.32 are vulnerable against an improper access control, which makes it possible for admins to ban themselves leading to their deactivation from Ifme account and complete loss of admin access to Ifme."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ifmeorg/ifme/commit/d1f570c458d41667df801fc9c40a18b181a2d923",
              "refsource": "MISC",
              "url": "https://github.com/ifmeorg/ifme/commit/d1f570c458d41667df801fc9c40a18b181a2d923"
            },
            {
              "name": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25991",
              "refsource": "MISC",
              "url": "https://www.whitesourcesoftware.com/vulnerability-database/CVE-2021-25991"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update version to v7.32.1 or later"
          }
        ],
        "source": {
          "advisory": "https://www.whitesourcesoftware.com/vulnerability-database/",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "478c68dd-22c1-4a41-97cd-654224dfacff",
    "assignerShortName": "Mend",
    "cveId": "CVE-2021-25991",
    "datePublished": "2021-12-29T09:10:19.040Z",
    "dateReserved": "2021-01-22T00:00:00.000Z",
    "dateUpdated": "2025-04-30T15:43:44.984Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-26118 (GCVE-0-2021-26118)

Vulnerability from cvelistv5 – Published: 2021-01-27 18:55 – Updated: 2025-02-13 16:27
VLAI
Title
Flaw in ActiveMQ Artemis OpenWire support
Summary
While investigating ARTEMIS-2964 it was found that the creation of advisory messages in the OpenWire protocol head of Apache ActiveMQ Artemis 2.15.0 bypassed policy based access control for the entire session. Production of advisory messages was not subject to access control in error.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Apache Software Foundation Apache ActiveMQ Artemis Affected: unspecified , < 2.16.0 (custom)
Create a notification for this product.
Credits
Apache ActiveMQ would like to thank Francesco Marchioni (Red Hat) for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:19:20.389Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://mail-archives.apache.org/mod_mbox/activemq-users/202101.mbox/%3CCAH%2BvQmMUNnkiXv2-d3ucdErWOsdnLi6CgnK%2BVfixyJvTgTuYig%40mail.gmail.com%3E"
          },
          {
            "name": "[announce] 20210127 CVE-2021-26118: Flaw in ActiveMQ Artemis OpenWire support",
            "tags": [
              "mailing-list",
              "x_refsource_MLIST",
              "x_transferred"
            ],
            "url": "https://lists.apache.org/thread.html/rafd5d7cf303772a0118865262946586921a65ebd98fc24f56c812574%40%3Cannounce.apache.org%3E"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20210827-0002/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Apache ActiveMQ Artemis",
          "vendor": "Apache Software Foundation",
          "versions": [
            {
              "lessThan": "2.16.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Apache ActiveMQ  would like to thank Francesco Marchioni (Red Hat) for reporting this issue."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "While investigating ARTEMIS-2964 it was found that the creation of advisory messages in the OpenWire protocol head of Apache ActiveMQ Artemis 2.15.0 bypassed policy based access control for the entire session. Production of advisory messages was not subject to access control in error."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-03T20:20:55.000Z",
        "orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
        "shortName": "apache"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://mail-archives.apache.org/mod_mbox/activemq-users/202101.mbox/%3CCAH%2BvQmMUNnkiXv2-d3ucdErWOsdnLi6CgnK%2BVfixyJvTgTuYig%40mail.gmail.com%3E"
        },
        {
          "name": "[announce] 20210127 CVE-2021-26118: Flaw in ActiveMQ Artemis OpenWire support",
          "tags": [
            "mailing-list",
            "x_refsource_MLIST"
          ],
          "url": "https://lists.apache.org/thread.html/rafd5d7cf303772a0118865262946586921a65ebd98fc24f56c812574%40%3Cannounce.apache.org%3E"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210827-0002/"
        }
      ],
      "source": {
        "defect": [
          "https://issues.apache.org/jira/browse/ARTEMIS-2964"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Flaw in ActiveMQ Artemis OpenWire support",
      "workarounds": [
        {
          "lang": "en",
          "value": "Upgrade to Apache ActiveMQ Artemis 2.16.0"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@apache.org",
          "ID": "CVE-2021-26118",
          "STATE": "PUBLIC",
          "TITLE": "Flaw in ActiveMQ Artemis OpenWire support"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Apache ActiveMQ Artemis",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "2.16.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Apache Software Foundation"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Apache ActiveMQ  would like to thank Francesco Marchioni (Red Hat) for reporting this issue."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "While investigating ARTEMIS-2964 it was found that the creation of advisory messages in the OpenWire protocol head of Apache ActiveMQ Artemis 2.15.0 bypassed policy based access control for the entire session. Production of advisory messages was not subject to access control in error."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://mail-archives.apache.org/mod_mbox/activemq-users/202101.mbox/%3CCAH%2BvQmMUNnkiXv2-d3ucdErWOsdnLi6CgnK%2BVfixyJvTgTuYig%40mail.gmail.com%3E",
              "refsource": "MISC",
              "url": "https://mail-archives.apache.org/mod_mbox/activemq-users/202101.mbox/%3CCAH%2BvQmMUNnkiXv2-d3ucdErWOsdnLi6CgnK%2BVfixyJvTgTuYig%40mail.gmail.com%3E"
            },
            {
              "name": "[announce] 20210127 CVE-2021-26118: Flaw in ActiveMQ Artemis OpenWire support",
              "refsource": "MLIST",
              "url": "https://lists.apache.org/thread.html/rafd5d7cf303772a0118865262946586921a65ebd98fc24f56c812574@%3Cannounce.apache.org%3E"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20210827-0002/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20210827-0002/"
            }
          ]
        },
        "source": {
          "defect": [
            "https://issues.apache.org/jira/browse/ARTEMIS-2964"
          ],
          "discovery": "UNKNOWN"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Upgrade to Apache ActiveMQ Artemis 2.16.0"
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
    "assignerShortName": "apache",
    "cveId": "CVE-2021-26118",
    "datePublished": "2021-01-27T18:55:13.000Z",
    "dateReserved": "2021-01-25T00:00:00.000Z",
    "dateUpdated": "2025-02-13T16:27:51.360Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-1

Phases: Architecture and Design, Operation

Description:

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
Mitigation ID: MIT-46

Phase: Architecture and Design

Strategy: Separation of Privilege

Description:

  • Compartmentalize the system to have "safe" areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
  • Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
CAPEC-19: Embedding Scripts within Scripts

An adversary leverages the capability to execute their own script by embedding it within other scripts that the target software is likely to execute due to programs' vulnerabilities that are brought on by allowing remote hosts to execute scripts.

CAPEC-441: Malicious Logic Insertion

An adversary installs or adds malicious logic (also known as malware) into a seemingly benign component of a fielded system. This logic is often hidden from the user of the system and works behind the scenes to achieve negative impacts. With the proliferation of mass digital storage and inexpensive multimedia devices, Bluetooth and 802.11 support, new attack vectors for spreading malware are emerging for things we once thought of as innocuous greeting cards, picture frames, or digital projectors. This pattern of attack focuses on systems already fielded and used in operation as opposed to systems and their components that are still under development and part of the supply chain.

CAPEC-478: Modification of Windows Service Configuration

An adversary exploits a weakness in access control to modify the execution parameters of a Windows service. The goal of this attack is to execute a malicious binary in place of an existing service.

CAPEC-479: Malicious Root Certificate

An adversary exploits a weakness in authorization and installs a new root certificate on a compromised system. Certificates are commonly used for establishing secure TLS/SSL communications within a web browser. When a user attempts to browse a website that presents a certificate that is not trusted an error message will be displayed to warn the user of the security risk. Depending on the security settings, the browser may not allow the user to establish a connection to the website. Adversaries have used this technique to avoid security warnings prompting users when compromised systems connect over HTTPS to adversary controlled web servers that spoof legitimate websites in order to collect login credentials.

CAPEC-502: Intent Spoof

An adversary, through a previously installed malicious application, issues an intent directed toward a specific trusted application's component in an attempt to achieve a variety of different objectives including modification of data, information disclosure, and data injection. Components that have been unintentionally exported and made public are subject to this type of an attack. If the component trusts the intent's action without verififcation, then the target application performs the functionality at the adversary's request, helping the adversary achieve the desired negative technical impact.

CAPEC-503: WebView Exposure

An adversary, through a malicious web page, accesses application specific functionality by leveraging interfaces registered through WebView's addJavascriptInterface API. Once an interface is registered to WebView through addJavascriptInterface, it becomes global and all pages loaded in the WebView can call this interface.

CAPEC-536: Data Injected During Configuration

An attacker with access to data files and processes on a victim's system injects malicious data into critical operational data during configuration or recalibration, causing the victim's system to perform in a suboptimal manner that benefits the adversary.

CAPEC-546: Incomplete Data Deletion in a Multi-Tenant Environment

An adversary obtains unauthorized information due to insecure or incomplete data deletion in a multi-tenant environment. If a cloud provider fails to completely delete storage and data from former cloud tenants' systems/resources, once these resources are allocated to new, potentially malicious tenants, the latter can probe the provided resources for sensitive information still there.

CAPEC-550: Install New Service

When an operating system starts, it also starts programs called services or daemons. Adversaries may install a new service which will be executed at startup (on a Windows system, by modifying the registry). The service name may be disguised by using a name from a related operating system or benign software. Services are usually run with elevated privileges.

CAPEC-551: Modify Existing Service

When an operating system starts, it also starts programs called services or daemons. Modifying existing services may break existing services or may enable services that are disabled/not commonly used.

CAPEC-552: Install Rootkit

An adversary exploits a weakness in authentication to install malware that alters the functionality and information provide by targeted operating system API calls. Often referred to as rootkits, it is often used to hide the presence of programs, files, network connections, services, drivers, and other system components.

CAPEC-556: Replace File Extension Handlers

When a file is opened, its file handler is checked to determine which program opens the file. File handlers are configuration properties of many operating systems. Applications can modify the file handler for a given file extension to call an arbitrary program when a file with the given extension is opened.

CAPEC-558: Replace Trusted Executable

An adversary exploits weaknesses in privilege management or access control to replace a trusted executable with a malicious version and enable the execution of malware when that trusted executable is called.

CAPEC-562: Modify Shared File

An adversary manipulates the files in a shared location by adding malicious programs, scripts, or exploit code to valid content. Once a user opens the shared content, the tainted content is executed.

CAPEC-563: Add Malicious File to Shared Webroot

An adversaries may add malicious content to a website through the open file share and then browse to that content with a web browser to cause the server to execute the content. The malicious content will typically run under the context and permissions of the web server process, often resulting in local system or administrative privileges depending on how the web server is configured.

CAPEC-564: Run Software at Logon

Operating system allows logon scripts to be run whenever a specific user or users logon to a system. If adversaries can access these scripts, they may insert additional code into the logon script. This code can allow them to maintain persistence or move laterally within an enclave because it is executed every time the affected user or users logon to a computer. Modifying logon scripts can effectively bypass workstation and enclave firewalls. Depending on the access configuration of the logon scripts, either local credentials or a remote administrative account may be necessary.

CAPEC-578: Disable Security Software

An adversary exploits a weakness in access control to disable security tools so that detection does not occur. This can take the form of killing processes, deleting registry keys so that tools do not start at run time, deleting log files, or other methods.

Back to CWE stats page