Common Weakness Enumeration

CWE-125

Weakness Allowed

Out-of-bounds Read

Abstraction: Base · Status: Draft

The product reads data past the end, or before the beginning, of the intended buffer.

Dimensions

  • Behavior-Type: Read
  • Resource-Type: Memory Buffer
  • Resource-Property: Out-of-bounds
Mapping guidance

This CWE entry is at the Base level of abstraction, which is a preferred level of abstraction for mapping to the root causes of vulnerabilities.

Carefully read both the name and description to ensure that this mapping is an appropriate fit. Do not try to 'force' a mapping to a lower-level Base/Variant simply to comply with this preferred level of abstraction.

Relationships and members
ChildOf: CWE-119 · View CWE-1000
ChildOf: CWE-119 · View CWE-1003
ChildOf: CWE-119 · View CWE-1305
ChildOf: CWE-119 · View CWE-1340
Modes of introduction
Implementation
Detection methods

Fuzzing

Fuzz testing (fuzzing) is a powerful technique for generating large numbers of diverse inputs - either randomly or algorithmically - and dynamically invoking the code with those inputs. Even with random inputs, it is often capable of generating unexpected results such as crashes, memory corruption, or resource consumption. Fuzzing effectively produces repeatable test cases that clearly indicate bugs, which helps developers to diagnose the issues.

Effectiveness: High

Automated Static Analysis

Automated static analysis, commonly referred to as Static Application Security Testing (SAST), can find some instances of this weakness by analyzing source code (or binary/compiled code) without having to execute it. Typically, this is done by building a model of data flow and control flow, then searching for potentially-vulnerable patterns that connect "sources" (origins of input) with "sinks" (destinations where the data interacts with external components, a lower layer such as the OS, etc.)

Effectiveness: High

Automated Dynamic Analysis

Use tools that are integrated during compilation to insert runtime error-checking mechanisms related to memory safety errors, such as AddressSanitizer (ASan) for C/C++ [REF-1518].

Effectiveness: Moderate

Crafted inputs are necessary to reach the code containing the error, such as generated by fuzzers. Also, these tools may reduce performance, and they only report the error condition - not the original mistake that led to the error.

Content history
Submission: PLOVER · 2006-07-19 · CWE Draft 3
Contribution: Abhi Balakrishnan · 2024-02-29 · CWE 4.15

Provided diagram to improve CWE usability

Modification: CWE Content Team · MITRE · 2008-09-08 · CWE 1.0

updated Applicable_Platforms, Relationships, Taxonomy_Mappings, Weakness_Ordinalities

Modification: CWE Content Team · MITRE · 2009-10-29 · CWE 1.6

updated Description

Modification: CWE Content Team · MITRE · 2010-09-27 · CWE 1.10

updated Relationships

Modification: CWE Content Team · MITRE · 2011-06-01 · CWE 1.13

updated Common_Consequences

Modification: CWE Content Team · MITRE · 2012-05-11 · CWE 2.2

updated Demonstrative_Examples, References, Relationships

Modification: CWE Content Team · MITRE · 2014-06-23 · CWE 2.7

updated Related_Attack_Patterns

Modification: CWE Content Team · MITRE · 2014-07-30 · CWE 2.8

updated Relationships, Taxonomy_Mappings

Modification: CWE Content Team · MITRE · 2015-12-07 · CWE 2.9

updated Relationships

Modification: CWE Content Team · MITRE · 2017-11-08 · CWE 3.0

updated Causal_Nature, Observed_Examples, Taxonomy_Mappings

Modification: CWE Content Team · MITRE · 2018-03-27 · CWE 3.1

updated Description

Modification: CWE Content Team · MITRE · 2019-01-03 · CWE 3.2

updated Relationships

Modification: CWE Content Team · MITRE · 2019-06-20 · CWE 3.3

updated Description, Related_Attack_Patterns

Modification: CWE Content Team · MITRE · 2019-09-19 · CWE 3.4

updated Common_Consequences, Observed_Examples, Potential_Mitigations, References, Relationships

Modification: CWE Content Team · MITRE · 2020-02-24 · CWE 4.0

updated Potential_Mitigations, Relationships, Taxonomy_Mappings

Modification: CWE Content Team · MITRE · 2020-06-25 · CWE 4.1

updated Observed_Examples, Potential_Mitigations

Modification: CWE Content Team · MITRE · 2020-08-20 · CWE 4.2

updated Observed_Examples, Potential_Mitigations, Relationships

Modification: CWE Content Team · MITRE · 2020-12-10 · CWE 4.3

updated Related_Attack_Patterns, Relationships

Modification: CWE Content Team · MITRE · 2021-07-20 · CWE 4.5

updated Observed_Examples, Relationships

Modification: CWE Content Team · MITRE · 2022-04-28 · CWE 4.7

updated Research_Gaps

Modification: CWE Content Team · MITRE · 2022-06-28 · CWE 4.8

updated Observed_Examples, Relationships

Modification: CWE Content Team · MITRE · 2022-10-13 · CWE 4.9

updated Applicable_Platforms, Relationships, Taxonomy_Mappings

Modification: CWE Content Team · MITRE · 2023-01-31 · CWE 4.10

updated Description

Modification: CWE Content Team · MITRE · 2023-04-27 · CWE 4.11

updated Detection_Factors, References, Relationships

Modification: CWE Content Team · MITRE · 2023-06-29 · CWE 4.12

updated Mapping_Notes, Relationships

Modification: CWE Content Team · MITRE · 2023-10-26 · CWE 4.13

updated Observed_Examples

Modification: CWE Content Team · MITRE · 2024-07-16 · CWE 4.15

updated Alternate_Terms, Common_Consequences, Description, Diagram, Weakness_Ordinalities

Modification: CWE Content Team · MITRE · 2024-11-19 · CWE 4.16

updated Observed_Examples, Relationships

Modification: CWE Content Team · MITRE · 2025-09-09 · CWE 4.18

updated Affected_Resources, Demonstrative_Examples, Functional_Areas

Modification: CWE Content Team · MITRE · 2025-12-11 · CWE 4.19

updated Applicable_Platforms, Detection_Factors, References, Relationships

Modification: CWE Content Team · MITRE · 2026-10-28 · CWE 5.0

updated Applicable_Platforms, Demonstrative_Examples, Dimensions, Observed_Examples, References, Relationships, Taxonomy_Mappings

14392 vulnerabilities reference this CWE, most recent first.

CVE-2019-6568 (GCVE-0-2019-6568)

Vulnerability from cvelistv5 – Published: 2019-04-17 13:40 – Updated: 2026-06-03 13:29
VLAI
Summary
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-03 13:27 UTC
CWE
Assigner
siemens CNA under the icscert root
CNA scorecard C 65/100 over 88 records in the last 180 days details
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1604 Affected: All versions
Create a notification for this product.
Siemens SIMATIC CP 1616 Affected: All versions
Create a notification for this product.
Siemens SIMATIC CP 343-1 Advanced Affected: All versions
Create a notification for this product.
Siemens SIMATIC CP 443-1 Affected: All versions < V3.3
Create a notification for this product.
Siemens SIMATIC CP 443-1 Advanced Affected: All versions < V3.3
Create a notification for this product.
Siemens SIMATIC CP 443-1 OPC UA Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC ET 200S IM151-8 PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC ET 200S IM151-8F PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Affected: All versions < V2.1.6
Create a notification for this product.
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V2.7
Create a notification for this product.
Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) Affected: All versions < V15.1 Upd4
Create a notification for this product.
Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) Affected: All versions < V15.1 Upd4
Create a notification for this product.
Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Upd4
Create a notification for this product.
Siemens SIMATIC IPC DiagMonitor Affected: All versions < V5.1.3
Create a notification for this product.
Siemens SIMATIC RF182C Affected: All versions
Create a notification for this product.
Siemens SIMATIC RF185C Affected: All versions < V1.1.0
Create a notification for this product.
Siemens SIMATIC RF186C Affected: All versions < V1.1.0
Create a notification for this product.
Siemens SIMATIC RF188C Affected: All versions < V1.1.0
Create a notification for this product.
Siemens SIMATIC RF600R family Affected: All versions < V3.2.1
Create a notification for this product.
Siemens SIMATIC RFID 181EIP Affected: All versions
Create a notification for this product.
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions < V2.6.1
Create a notification for this product.
Siemens SIMATIC S7-1500 Software Controller Affected: All versions < V2.7
Create a notification for this product.
Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.16
Create a notification for this product.
Siemens SIMATIC S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC S7-300 CPU 319-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions < V2.0 SP1 UPD1
Create a notification for this product.
Siemens SIMATIC Teleservice Adapter IE Advanced Affected: All versions
Create a notification for this product.
Siemens SIMATIC Teleservice Adapter IE Basic Affected: All versions
Create a notification for this product.
Siemens SIMATIC Teleservice Adapter IE Standard Affected: All versions
Create a notification for this product.
Siemens SIMATIC WinAC RTX 2010 Affected: All versions < V2010 SP3
Create a notification for this product.
Siemens SIMATIC WinAC RTX F 2010 Affected: All versions < V2010 SP3
Create a notification for this product.
Siemens SIMATIC WinCC Runtime Advanced Affected: All versions < V15.1 Upd4
Create a notification for this product.
Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants) Affected: All versions < V1.1.3
Create a notification for this product.
Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Affected: All versions < V2.1.3
Create a notification for this product.
Siemens SINAMICS G130 V4.6 Control Unit Affected: All versions
Create a notification for this product.
Siemens SINAMICS G130 V4.7 Control Unit Affected: All versions
Create a notification for this product.
Siemens SINAMICS G130 V4.7 SP1 Control Unit Affected: All versions
Create a notification for this product.
Siemens SINAMICS G130 V4.8 Control Unit Affected: All versions < V4.8 HF6
Create a notification for this product.

50 of 96 products shown. All of them on the page of CVE-2019-6568.

Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:22.207Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-6568",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-03T13:27:45.600260Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-03T13:29:34.953Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC DiagMonitor",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF182C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF185C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF186C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF188C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF600R family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RFID 181EIP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0 SP1 UPD1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S210",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF33"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF10"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP Manager",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:03.049Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-6568",
    "datePublished": "2019-04-17T13:40:24.000Z",
    "dateReserved": "2019-01-22T00:00:00.000Z",
    "dateUpdated": "2026-06-03T13:29:34.953Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2019-6547 (GCVE-0-2019-6547)

Vulnerability from cvelistv5 – Published: 2019-02-28 21:00 – Updated: 2024-09-17 01:16
VLAI
Summary
Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.84 and prior. An out-of-bounds read vulnerability may cause the software to crash due to lacking user input validation for processing project files.
Severity
No CVSS data available.
CWE
  • CWE-125 - OUT-OF-BOUNDS READ CWE-125
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 347 records in the last 180 days details
References
Impacted products
Vendor Product Version
ICS-CERT Delta Industrial Automation CNCSoft Affected: CNCSoft ScreenEditor Version 1.00.84 and prior.
Create a notification for this product.
Date Public
2019-02-19 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.930Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "107086",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/107086"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Delta Industrial Automation CNCSoft",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "CNCSoft ScreenEditor Version 1.00.84 and prior."
            }
          ]
        }
      ],
      "datePublic": "2019-02-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.84 and prior. An out-of-bounds read vulnerability may cause the software to crash due to lacking user input validation for processing project files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "OUT-OF-BOUNDS READ CWE-125",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-01T10:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "107086",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/107086"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-02-19T00:00:00",
          "ID": "CVE-2019-6547",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Delta Industrial Automation CNCSoft",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "CNCSoft ScreenEditor Version 1.00.84 and prior."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.84 and prior. An out-of-bounds read vulnerability may cause the software to crash due to lacking user input validation for processing project files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS READ CWE-125"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "107086",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/107086"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6547",
    "datePublished": "2019-02-28T21:00:00.000Z",
    "dateReserved": "2019-01-22T00:00:00.000Z",
    "dateUpdated": "2024-09-17T01:16:41.112Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6522 (GCVE-0-2019-6522)

Vulnerability from cvelistv5 – Published: 2019-03-05 21:00 – Updated: 2024-09-17 02:32
VLAI
Summary
Moxa IKS and EDS fails to properly check array bounds which may allow an attacker to read device memory on arbitrary addresses, and may allow an attacker to retrieve sensitive data or cause device reboot.
Severity
No CVSS data available.
CWE
  • CWE-125 - Out-of-bounds read CWE-125
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 347 records in the last 180 days details
References
Impacted products
Vendor Product Version
ICS-CERT Moxa IKS, EDS Affected: IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior
Create a notification for this product.
Date Public
2019-03-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.392Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-057-01"
          },
          {
            "name": "107178",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/107178"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Moxa IKS, EDS",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior"
            }
          ]
        }
      ],
      "datePublic": "2019-03-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Moxa IKS and EDS fails to properly check array bounds which may allow an attacker to read device memory on arbitrary addresses, and may allow an attacker to retrieve sensitive data or cause device reboot."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "Out-of-bounds read CWE-125",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-06T10:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-057-01"
        },
        {
          "name": "107178",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/107178"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-03-05T00:00:00",
          "ID": "CVE-2019-6522",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Moxa IKS, EDS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Moxa IKS and EDS fails to properly check array bounds which may allow an attacker to read device memory on arbitrary addresses, and may allow an attacker to retrieve sensitive data or cause device reboot."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Out-of-bounds read CWE-125"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-057-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-057-01"
            },
            {
              "name": "107178",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/107178"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6522",
    "datePublished": "2019-03-05T21:00:00.000Z",
    "dateReserved": "2019-01-22T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:32:19.762Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5148 (GCVE-0-2019-5148)

Vulnerability from cvelistv5 – Published: 2020-02-25 15:57 – Updated: 2024-08-04 19:47
VLAI
Summary
An exploitable denial-of-service vulnerability exists in ServiceAgent functionality of the Moxa AWK-3131A, firmware version 1.13. A specially crafted packet can cause an integer underflow, triggering a large memcpy that will access unmapped or out-of-bounds memory. An attacker can send this packet while unauthenticated to trigger this vulnerability.
CWE
Assigner
talos CNA under the mitre root
CNA scorecard C 60/100 over 46 records in the last 180 days details
References
Impacted products
Vendor Product Version
n/a Moxa Affected: Moxa AWK-3131A Firmware version 1.13
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:47:56.642Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0938"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Moxa",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Moxa AWK-3131A Firmware version 1.13"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable denial-of-service vulnerability exists in ServiceAgent functionality of the Moxa AWK-3131A, firmware version 1.13. A specially crafted packet can cause an integer underflow, triggering a large memcpy that will access unmapped or out-of-bounds memory. An attacker can send this packet while unauthenticated to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T17:34:54.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0938"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2019-5148",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Moxa",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Moxa AWK-3131A Firmware version 1.13"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable denial-of-service vulnerability exists in ServiceAgent functionality of the Moxa AWK-3131A, firmware version 1.13. A specially crafted packet can cause an integer underflow, triggering a large memcpy that will access unmapped or out-of-bounds memory. An attacker can send this packet while unauthenticated to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.5,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0938",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0938"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2019-5148",
    "datePublished": "2020-02-25T15:57:49.000Z",
    "dateReserved": "2019-01-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T19:47:56.642Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5090 (GCVE-0-2019-5090)

Vulnerability from cvelistv5 – Published: 2019-12-11 23:40 – Updated: 2024-08-04 19:47
VLAI
Summary
An exploitable information disclosure vulnerability exists in the DICOM packet-parsing functionality of LEADTOOLS libltdic.so, version 20.0.2019.3.15. A specially crafted packet can cause an out-of-bounds read, resulting in information disclosure. An attacker can send a packet to trigger this vulnerability.
CWE
Assigner
talos CNA under the mitre root
CNA scorecard C 60/100 over 46 records in the last 180 days details
References
Impacted products
Vendor Product Version
n/a LEADTOOLS libltdic.so Affected: 20.0.2019.3.15
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:47:55.975Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0882"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LEADTOOLS libltdic.so",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "20.0.2019.3.15"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable information disclosure vulnerability exists in the DICOM packet-parsing functionality of LEADTOOLS libltdic.so, version 20.0.2019.3.15. A specially crafted packet can cause an out-of-bounds read, resulting in information disclosure. An attacker can send a packet to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T17:34:01.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0882"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2019-5090",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LEADTOOLS libltdic.so",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "20.0.2019.3.15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable information disclosure vulnerability exists in the DICOM packet-parsing functionality of LEADTOOLS libltdic.so, version 20.0.2019.3.15. A specially crafted packet can cause an out-of-bounds read, resulting in information disclosure. An attacker can send a packet to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.1,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0882",
              "refsource": "CONFIRM",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0882"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2019-5090",
    "datePublished": "2019-12-11T23:40:09.000Z",
    "dateReserved": "2019-01-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T19:47:55.975Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5065 (GCVE-0-2019-5065)

Vulnerability from cvelistv5 – Published: 2019-09-05 16:07 – Updated: 2024-08-04 19:47
VLAI
Summary
An exploitable information disclosure vulnerability exists in the packet-parsing functionality of Blynk-Library v0.6.1. A specially crafted packet can cause an unterminated strncpy, resulting in information disclosure. An attacker can send a packet to trigger this vulnerability.
CWE
Assigner
talos CNA under the mitre root
CNA scorecard C 60/100 over 46 records in the last 180 days details
References
Impacted products
Vendor Product Version
n/a Blynck Inc Affected: Blynk Blynk-Library v0.6.1
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:47:56.665Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0854"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Blynck Inc",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Blynk Blynk-Library v0.6.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable information disclosure vulnerability exists in the packet-parsing functionality of Blynk-Library v0.6.1. A specially crafted packet can cause an unterminated strncpy, resulting in information disclosure. An attacker can send a packet to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T17:33:42.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0854"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2019-5065",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Blynck Inc",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Blynk Blynk-Library v0.6.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable information disclosure vulnerability exists in the packet-parsing functionality of Blynk-Library v0.6.1. A specially crafted packet can cause an unterminated strncpy, resulting in information disclosure. An attacker can send a packet to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 5.3,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0854",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0854"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2019-5065",
    "datePublished": "2019-09-05T16:07:42.000Z",
    "dateReserved": "2019-01-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T19:47:56.665Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5034 (GCVE-0-2019-5034)

Vulnerability from cvelistv5 – Published: 2019-08-20 21:07 – Updated: 2024-08-04 19:40
VLAI
Summary
An exploitable information disclosure vulnerability exists in the Weave Legacy Pairing functionality of Nest Cam IQ Indoor version 4620002. A set of specially crafted weave packets can cause an out of bounds read, resulting in information disclosure. An attacker can send packets to trigger this vulnerability.
CWE
Assigner
talos CNA under the mitre root
CNA scorecard C 60/100 over 46 records in the last 180 days details
References
Impacted products
Vendor Product Version
n/a Nest Labs Affected: Nest Labs Nest Cam IQ Indoor version 4620002
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:40:49.198Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0797"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nest Labs",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Nest Labs Nest Cam IQ Indoor version 4620002"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable information disclosure vulnerability exists in the Weave Legacy Pairing functionality of Nest Cam IQ Indoor version 4620002. A set of specially crafted weave packets can cause an out of bounds read, resulting in information disclosure. An attacker can send packets to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T17:33:06.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0797"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2019-5034",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nest Labs",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Nest Labs Nest Cam IQ Indoor version 4620002"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable information disclosure vulnerability exists in the Weave Legacy Pairing functionality of Nest Cam IQ Indoor version 4620002. A set of specially crafted weave packets can cause an out of bounds read, resulting in information disclosure. An attacker can send packets to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 5.3,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0797",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2019-0797"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2019-5034",
    "datePublished": "2019-08-20T21:07:10.000Z",
    "dateReserved": "2019-01-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T19:40:49.198Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5033 (GCVE-0-2019-5033)

Vulnerability from cvelistv5 – Published: 2019-08-21 17:01 – Updated: 2024-08-04 19:40
VLAI
Summary
An exploitable out-of-bounds read vulnerability exists in the Number record parser of Aspose Aspose.Cells 19.1.0 library. A specially crafted XLS file can cause an out-of-bounds read, resulting in remote code execution. An attacker needs to provide a malformed file to the victim to trigger the vulnerability.
CWE
Assigner
talos CNA under the mitre root
CNA scorecard C 60/100 over 46 records in the last 180 days details
References
Impacted products
Vendor Product Version
n/a Aspose Affected: Aspose Aspose.Cells 19.1.0
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:40:48.967Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0795"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aspose",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Aspose Aspose.Cells 19.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable out-of-bounds read vulnerability exists in the Number record parser of Aspose Aspose.Cells 19.1.0 library. A specially crafted XLS file can cause an out-of-bounds read, resulting in remote code execution. An attacker needs to provide a malformed file to the victim to trigger the vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T17:33:05.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0795"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2019-5033",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aspose",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Aspose Aspose.Cells 19.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable out-of-bounds read vulnerability exists in the Number record parser of Aspose Aspose.Cells 19.1.0 library. A specially crafted XLS file can cause an out-of-bounds read, resulting in remote code execution. An attacker needs to provide a malformed file to the victim to trigger the vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0795",
              "refsource": "MISC",
              "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0795"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2019-5033",
    "datePublished": "2019-08-21T17:01:48.000Z",
    "dateReserved": "2019-01-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T19:40:48.967Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5032 (GCVE-0-2019-5032)

Vulnerability from cvelistv5 – Published: 2019-08-21 17:02 – Updated: 2024-08-04 19:40
VLAI
Summary
An exploitable out-of-bounds read vulnerability exists in the LabelSst record parser of Aspose Aspose.Cells 19.1.0 library. A specially crafted XLS file can cause an out-of-bounds read, resulting in remote code execution. An attacker needs to provide a malformed file to the victim to trigger the vulnerability.
CWE
Assigner
talos CNA under the mitre root
CNA scorecard C 60/100 over 46 records in the last 180 days details
References
Impacted products
Vendor Product Version
n/a Aspose Affected: Aspose Aspose.Cells 19.1.0
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:40:49.304Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0794"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aspose",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Aspose Aspose.Cells 19.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An exploitable out-of-bounds read vulnerability exists in the LabelSst record parser of Aspose Aspose.Cells 19.1.0 library. A specially crafted XLS file can cause an out-of-bounds read, resulting in remote code execution. An attacker needs to provide a malformed file to the victim to trigger the vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-19T17:33:04.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0794"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2019-5032",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aspose",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Aspose Aspose.Cells 19.1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An exploitable out-of-bounds read vulnerability exists in the LabelSst record parser of Aspose Aspose.Cells 19.1.0 library. A specially crafted XLS file can cause an out-of-bounds read, resulting in remote code execution. An attacker needs to provide a malformed file to the victim to trigger the vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0794",
              "refsource": "MISC",
              "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0794"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2019-5032",
    "datePublished": "2019-08-21T17:02:05.000Z",
    "dateReserved": "2019-01-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T19:40:49.304Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-3861 (GCVE-0-2019-3861)

Vulnerability from cvelistv5 – Published: 2019-03-25 18:30 – Updated: 2026-10-14 06:35
VLAI
Summary
An out of bounds read flaw was discovered in libssh2 before 1.8.1 in the way SSH packets with a padding length value greater than the packet length are parsed. A remote attacker who compromises a SSH server may be able to cause a Denial of Service or read data in the client memory.
CWE
Assigner
redhat CNA under the redhat root
CNA scorecard B 82/100 over 1231 records in the last 180 days details
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:18.629Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.libssh2.org/CVE-2019-3861.html"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-3861"
          },
          {
            "name": "[debian-lts-announce] 20190326 [SECURITY] [DLA 1730-1] libssh2 security update",
            "tags": [
              "mailing-list",
              "x_refsource_MLIST",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2019/03/msg00032.html"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20190327-0005/"
          },
          {
            "name": "openSUSE-SU-2019:1075",
            "tags": [
              "vendor-advisory",
              "x_refsource_SUSE",
              "x_transferred"
            ],
            "url": "http://lists.opensuse.org/opensuse-security-announce/2019-03/msg00040.html"
          },
          {
            "name": "openSUSE-SU-2019:1109",
            "tags": [
              "vendor-advisory",
              "x_refsource_SUSE",
              "x_transferred"
            ],
            "url": "http://lists.opensuse.org/opensuse-security-announce/2019-04/msg00003.html"
          },
          {
            "name": "FEDORA-2019-3348cb4934",
            "tags": [
              "vendor-advisory",
              "x_refsource_FEDORA",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/5DK6VO2CEUTAJFYIKWNZKEKYMYR3NO2O/"
          },
          {
            "name": "DSA-4431",
            "tags": [
              "vendor-advisory",
              "x_refsource_DEBIAN",
              "x_transferred"
            ],
            "url": "https://www.debian.org/security/2019/dsa-4431"
          },
          {
            "name": "20190415 [SECURITY] [DSA 4431-1] libssh2 security update",
            "tags": [
              "mailing-list",
              "x_refsource_BUGTRAQ",
              "x_transferred"
            ],
            "url": "https://seclists.org/bugtraq/2019/Apr/25"
          },
          {
            "name": "RHSA-2019:2136",
            "tags": [
              "vendor-advisory",
              "x_refsource_REDHAT",
              "x_transferred"
            ],
            "url": "https://access.redhat.com/errata/RHSA-2019:2136"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.oracle.com/technetwork/security-advisory/cpuoct2019-5072832.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V3.1.5",
                "status": "affected",
                "version": "V3.1.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V3.1.5",
                "status": "affected",
                "version": "V3.1.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V3.1.5",
                "status": "affected",
                "version": "V3.1.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V3.1.5",
                "status": "affected",
                "version": "V3.1.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V3.1.5",
                "status": "affected",
                "version": "V3.1.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-14T06:35:31.280Z",
          "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "shortName": "siemens-SADP"
        },
        "references": [
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
          }
        ],
        "x_adpType": "supplier"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "libssh2",
          "vendor": "The libssh2 Project",
          "versions": [
            {
              "status": "affected",
              "version": "1.8.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An out of bounds read flaw was discovered in libssh2 before 1.8.1 in the way SSH packets with a padding length value greater than the packet length are parsed. A remote attacker who compromises a SSH server may be able to cause a Denial of Service or read data in the client memory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-16T17:41:00.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.libssh2.org/CVE-2019-3861.html"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-3861"
        },
        {
          "name": "[debian-lts-announce] 20190326 [SECURITY] [DLA 1730-1] libssh2 security update",
          "tags": [
            "mailing-list",
            "x_refsource_MLIST"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2019/03/msg00032.html"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20190327-0005/"
        },
        {
          "name": "openSUSE-SU-2019:1075",
          "tags": [
            "vendor-advisory",
            "x_refsource_SUSE"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2019-03/msg00040.html"
        },
        {
          "name": "openSUSE-SU-2019:1109",
          "tags": [
            "vendor-advisory",
            "x_refsource_SUSE"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2019-04/msg00003.html"
        },
        {
          "name": "FEDORA-2019-3348cb4934",
          "tags": [
            "vendor-advisory",
            "x_refsource_FEDORA"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/5DK6VO2CEUTAJFYIKWNZKEKYMYR3NO2O/"
        },
        {
          "name": "DSA-4431",
          "tags": [
            "vendor-advisory",
            "x_refsource_DEBIAN"
          ],
          "url": "https://www.debian.org/security/2019/dsa-4431"
        },
        {
          "name": "20190415 [SECURITY] [DSA 4431-1] libssh2 security update",
          "tags": [
            "mailing-list",
            "x_refsource_BUGTRAQ"
          ],
          "url": "https://seclists.org/bugtraq/2019/Apr/25"
        },
        {
          "name": "RHSA-2019:2136",
          "tags": [
            "vendor-advisory",
            "x_refsource_REDHAT"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2019:2136"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.oracle.com/technetwork/security-advisory/cpuoct2019-5072832.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2019-3861",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "libssh2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.8.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "The libssh2 Project"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An out of bounds read flaw was discovered in libssh2 before 1.8.1 in the way SSH packets with a padding length value greater than the packet length are parsed. A remote attacker who compromises a SSH server may be able to cause a Denial of Service or read data in the client memory."
            }
          ]
        },
        "impact": {
          "cvss": [
            [
              {
                "vectorString": "5.0/CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            ]
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.libssh2.org/CVE-2019-3861.html",
              "refsource": "MISC",
              "url": "https://www.libssh2.org/CVE-2019-3861.html"
            },
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-3861",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-3861"
            },
            {
              "name": "[debian-lts-announce] 20190326 [SECURITY] [DLA 1730-1] libssh2 security update",
              "refsource": "MLIST",
              "url": "https://lists.debian.org/debian-lts-announce/2019/03/msg00032.html"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20190327-0005/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20190327-0005/"
            },
            {
              "name": "openSUSE-SU-2019:1075",
              "refsource": "SUSE",
              "url": "http://lists.opensuse.org/opensuse-security-announce/2019-03/msg00040.html"
            },
            {
              "name": "openSUSE-SU-2019:1109",
              "refsource": "SUSE",
              "url": "http://lists.opensuse.org/opensuse-security-announce/2019-04/msg00003.html"
            },
            {
              "name": "FEDORA-2019-3348cb4934",
              "refsource": "FEDORA",
              "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/5DK6VO2CEUTAJFYIKWNZKEKYMYR3NO2O/"
            },
            {
              "name": "DSA-4431",
              "refsource": "DEBIAN",
              "url": "https://www.debian.org/security/2019/dsa-4431"
            },
            {
              "name": "20190415 [SECURITY] [DSA 4431-1] libssh2 security update",
              "refsource": "BUGTRAQ",
              "url": "https://seclists.org/bugtraq/2019/Apr/25"
            },
            {
              "name": "RHSA-2019:2136",
              "refsource": "REDHAT",
              "url": "https://access.redhat.com/errata/RHSA-2019:2136"
            },
            {
              "name": "https://www.oracle.com/technetwork/security-advisory/cpuoct2019-5072832.html",
              "refsource": "MISC",
              "url": "https://www.oracle.com/technetwork/security-advisory/cpuoct2019-5072832.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2019-3861",
    "datePublished": "2019-03-25T18:30:43.000Z",
    "dateReserved": "2019-01-03T00:00:00.000Z",
    "dateUpdated": "2026-10-14T06:35:31.280Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

Mitigation MIT-5
Implementation

Strategy: Input Validation

  • Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
  • When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
  • Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
  • To reduce the likelihood of introducing an out-of-bounds read, ensure that you validate and ensure correct calculations for any length argument, buffer size calculation, or offset. Be especially careful of relying on a sentinel (i.e. special character such as NUL) in untrusted inputs.
Mitigation
Architecture and Design

Strategy: Language Selection

Use a language that provides appropriate memory abstractions.

CAPEC-540: Overread Buffers

An adversary attacks a target by providing input that causes an application to read beyond the boundary of a defined buffer. This typically occurs when a value influencing where to start or stop reading is set to reflect positions outside of the valid memory location of the buffer. This type of attack may result in exposure of sensitive information, a system crash, or arbitrary code execution.