Common Weakness Enumeration
CWE-121
AllowedStack-based Buffer Overflow
Abstraction: Variant · Status: Draft
A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).
5215 vulnerabilities reference this CWE, most recent first.
CVE-2024-2981 (GCVE-0-2024-2981)
Vulnerability from cvelistv5 – Published: 2024-03-27 15:00 – Updated: 2024-08-12 18:03
VLAI
EPSS
VEX
Title
Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.258150 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.258150 | signaturepermissions-required |
| https://vuldb.com/?submit.301272 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | FH1202 |
Affected:
1.2.0.14(408)
|
|
| tenda | fh1202_firmware |
Affected:
1.2.0.14\(408\)
cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\(408\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:32:42.450Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-258150 | Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.258150"
},
{
"name": "VDB-258150 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.258150"
},
{
"name": "Submit #301272 | Tenda FH1202 V1.2.0.14(408) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.301272"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/form_fast_setting_wifi_set.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fh1202_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14\\(408\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2981",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-12T15:17:58.717197Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T18:03:57.487Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda FH1202 1.2.0.14(408) gefunden. Sie wurde als kritisch eingestuft. Es betrifft die Funktion form_fast_setting_wifi_set der Datei /goform/fast_setting_wifi_set. Mit der Manipulation des Arguments ssid mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-27T15:00:07.444Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-258150 | Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.258150"
},
{
"name": "VDB-258150 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.258150"
},
{
"name": "Submit #301272 | Tenda FH1202 V1.2.0.14(408) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.301272"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/form_fast_setting_wifi_set.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-27T08:10:17.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2981",
"datePublished": "2024-03-27T15:00:07.444Z",
"dateReserved": "2024-03-27T07:04:08.551Z",
"dateUpdated": "2024-08-12T18:03:57.487Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2980 (GCVE-0-2024-2980)
Vulnerability from cvelistv5 – Published: 2024-03-27 14:31 – Updated: 2024-08-01 19:32
VLAI
EPSS
VEX
Title
Tenda FH1202 execCommand formexeCommand stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258149 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.258149 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.258149 | signaturepermissions-required |
| https://vuldb.com/?submit.301270 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | FH1202 |
Affected:
1.2.0.14(408)
|
|
| tenda | fh1202_firmware |
Affected:
1.2.0.14\(408\)
cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\(408\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fh1202_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14\\(408\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2980",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-16T20:58:37.855774Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-16T20:59:35.183Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:32:42.558Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-258149 | Tenda FH1202 execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.258149"
},
{
"name": "VDB-258149 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.258149"
},
{
"name": "Submit #301270 | Tenda FH1202 V1.2.0.14(408) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.301270"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formexeCommand.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258149 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda FH1202 1.2.0.14(408) entdeckt. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formexeCommand der Datei /goform/execCommand. Dank Manipulation des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-27T14:31:03.946Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-258149 | Tenda FH1202 execCommand formexeCommand stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.258149"
},
{
"name": "VDB-258149 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.258149"
},
{
"name": "Submit #301270 | Tenda FH1202 V1.2.0.14(408) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.301270"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1202/formexeCommand.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-27T08:10:15.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1202 execCommand formexeCommand stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2980",
"datePublished": "2024-03-27T14:31:03.946Z",
"dateReserved": "2024-03-27T07:04:03.841Z",
"dateUpdated": "2024-08-01T19:32:42.558Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2979 (GCVE-0-2024-2979)
Vulnerability from cvelistv5 – Published: 2024-03-27 14:00 – Updated: 2024-08-27 20:38
VLAI
EPSS
VEX
Title
Tenda F1203 openSchedWifi setSchedWifi stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.258148 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.258148 | signaturepermissions-required |
| https://vuldb.com/?submit.301030 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | F1203 |
Affected:
2.0.1.6
|
|
| tenda | f1203_firmware |
Affected:
2.0.1.6
cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:32:42.935Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-258148 | Tenda F1203 openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.258148"
},
{
"name": "VDB-258148 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.258148"
},
{
"name": "Submit #301030 | Tenda F1203 V2.0.1.6 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.301030"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/setSchedWifi_end.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "f1203_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.6"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2979",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T15:56:00.862017Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-27T20:38:16.146Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "F1203",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda F1203 2.0.1.6 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion setSchedWifi der Datei /goform/openSchedWifi. Dank der Manipulation des Arguments schedStartTime/schedEndTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-27T14:00:10.347Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-258148 | Tenda F1203 openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.258148"
},
{
"name": "VDB-258148 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.258148"
},
{
"name": "Submit #301030 | Tenda F1203 V2.0.1.6 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.301030"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/setSchedWifi_end.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-27T08:10:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1203 openSchedWifi setSchedWifi stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2979",
"datePublished": "2024-03-27T14:00:10.347Z",
"dateReserved": "2024-03-27T07:04:01.248Z",
"dateUpdated": "2024-08-27T20:38:16.146Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2978 (GCVE-0-2024-2978)
Vulnerability from cvelistv5 – Published: 2024-03-27 14:00 – Updated: 2025-04-10 18:27
VLAI
EPSS
VEX
Title
Tenda F1203 setcfm formSetCfm stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.258147 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.258147 | signaturepermissions-required |
| https://vuldb.com/?submit.301029 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "f1203",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.6"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2978",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T17:28:12.907355Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-10T18:27:28.444Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:32:42.477Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-258147 | Tenda F1203 setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.258147"
},
{
"name": "VDB-258147 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.258147"
},
{
"name": "Submit #301029 | Tenda F1203 V2.0.1.6 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.301029"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formSetCfm.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "F1203",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda F1203 2.0.1.6 entdeckt. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion formSetCfm der Datei /goform/setcfm. Durch Beeinflussen des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-27T14:00:08.437Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-258147 | Tenda F1203 setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.258147"
},
{
"name": "VDB-258147 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.258147"
},
{
"name": "Submit #301029 | Tenda F1203 V2.0.1.6 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.301029"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formSetCfm.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-27T08:10:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1203 setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2978",
"datePublished": "2024-03-27T14:00:08.437Z",
"dateReserved": "2024-03-27T07:03:58.430Z",
"dateUpdated": "2025-04-10T18:27:28.444Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2977 (GCVE-0-2024-2977)
Vulnerability from cvelistv5 – Published: 2024-03-27 13:31 – Updated: 2024-08-12 15:44
VLAI
EPSS
VEX
Title
Tenda F1203 QuickIndex formQuickIndex stack-based overflow
Summary
A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.258146 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.258146 | signaturepermissions-required |
| https://vuldb.com/?submit.301028 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | F1203 |
Affected:
2.0.1.6
|
|
| tenda | fh1203_firmware |
Affected:
2.0.1.6
cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:32:42.493Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-258146 | Tenda F1203 QuickIndex formQuickIndex stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.258146"
},
{
"name": "VDB-258146 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.258146"
},
{
"name": "Submit #301028 | Tenda F1203 V2.0.1.6 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.301028"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fh1203_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.6"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2977",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-08T20:21:58.144621Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T15:44:08.153Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "F1203",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda F1203 2.0.1.6 ausgemacht. Es geht hierbei um die Funktion formQuickIndex der Datei /goform/QuickIndex. Durch das Beeinflussen des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-27T13:31:06.045Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-258146 | Tenda F1203 QuickIndex formQuickIndex stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.258146"
},
{
"name": "VDB-258146 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.258146"
},
{
"name": "Submit #301028 | Tenda F1203 V2.0.1.6 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.301028"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/formQuickIndex.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-27T08:09:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1203 QuickIndex formQuickIndex stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2977",
"datePublished": "2024-03-27T13:31:06.045Z",
"dateReserved": "2024-03-27T07:03:54.704Z",
"dateUpdated": "2024-08-12T15:44:08.153Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2976 (GCVE-0-2024-2976)
Vulnerability from cvelistv5 – Published: 2024-03-27 13:31 – Updated: 2024-08-21 14:56
VLAI
EPSS
VEX
Title
Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow
Summary
A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.258145 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.258145 | signaturepermissions-required |
| https://vuldb.com/?submit.300997 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | F1203 |
Affected:
2.0.1.6
|
|
| tenda | f1203_firmware |
Affected:
2.0.1.6
cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:32:42.512Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-258145 | Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.258145"
},
{
"name": "VDB-258145 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.258145"
},
{
"name": "Submit #300997 | Tenda F1203 V2.0.1.6 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.300997"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/R7WebsSecurityHandler.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "f1203_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.6"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2976",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T14:54:24.131979Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T14:56:30.998Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "F1203",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda F1203 2.0.1.6 wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion R7WebsSecurityHandler der Datei /goform/execCommand. Durch Manipulieren des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-27T13:31:04.472Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-258145 | Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.258145"
},
{
"name": "VDB-258145 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.258145"
},
{
"name": "Submit #300997 | Tenda F1203 V2.0.1.6 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.300997"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/R7WebsSecurityHandler.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-27T08:09:57.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2976",
"datePublished": "2024-03-27T13:31:04.472Z",
"dateReserved": "2024-03-27T07:03:52.505Z",
"dateUpdated": "2024-08-21T14:56:30.998Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2903 (GCVE-0-2024-2903)
Vulnerability from cvelistv5 – Published: 2024-03-26 20:31 – Updated: 2024-08-15 15:54
VLAI
EPSS
VEX
Title
Tenda AC7 GetParentControlInfo stack-based overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257946 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257946 | signaturepermissions-required |
| https://vuldb.com/?submit.300452 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:42.219Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257946 | Tenda AC7 GetParentControlInfo stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257946"
},
{
"name": "VDB-257946 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257946"
},
{
"name": "Submit #300452 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.300452"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2903",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-15T15:52:57.072819Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-15T15:54:17.573Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Hiervon betroffen ist die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-26T20:31:04.040Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257946 | Tenda AC7 GetParentControlInfo stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257946"
},
{
"name": "VDB-257946 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257946"
},
{
"name": "Submit #300452 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.300452"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-26T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-26T10:31:50.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC7 GetParentControlInfo stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2903",
"datePublished": "2024-03-26T20:31:04.040Z",
"dateReserved": "2024-03-26T09:26:47.360Z",
"dateUpdated": "2024-08-15T15:54:17.573Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2902 (GCVE-0-2024-2902)
Vulnerability from cvelistv5 – Published: 2024-03-26 20:00 – Updated: 2024-08-12 13:35
VLAI
EPSS
VEX
Title
Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257945 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257945 | signaturepermissions-required |
| https://vuldb.com/?submit.300449 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC7 |
Affected:
15.03.06.44
|
|
| tenda | ac7_firmware |
Affected:
15.03.06.44
cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:42.155Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257945 | Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257945"
},
{
"name": "VDB-257945 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257945"
},
{
"name": "Submit #300449 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.300449"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2902",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-15T19:37:20.952602Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-12T13:35:50.633Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 gefunden. Davon betroffen ist die Funktion fromSetWifiGusetBasic der Datei /goform/WifiGuestSet. Mittels Manipulieren des Arguments shareSpeed mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-26T20:00:08.534Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257945 | Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257945"
},
{
"name": "VDB-257945 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257945"
},
{
"name": "Submit #300449 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.300449"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-26T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-26T10:31:44.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2902",
"datePublished": "2024-03-26T20:00:08.534Z",
"dateReserved": "2024-03-26T09:26:38.442Z",
"dateUpdated": "2024-08-12T13:35:50.633Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2901 (GCVE-0-2024-2901)
Vulnerability from cvelistv5 – Published: 2024-03-26 20:00 – Updated: 2024-08-29 19:09
VLAI
EPSS
VEX
Title
Tenda AC7 openSchedWifi setSchedWifi stack-based overflow
Summary
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257944 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257944 | signaturepermissions-required |
| https://vuldb.com/?submit.300367 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:42.161Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257944 | Tenda AC7 openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257944"
},
{
"name": "VDB-257944 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257944"
},
{
"name": "Submit #300367 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.300367"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2901",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-20T20:50:19.200809Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T19:09:39.749Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle gefunden. Hierbei betrifft es die Funktion setSchedWifi der Datei /goform/openSchedWifi. Mittels dem Manipulieren des Arguments schedEndTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-26T20:00:06.887Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257944 | Tenda AC7 openSchedWifi setSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257944"
},
{
"name": "VDB-257944 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257944"
},
{
"name": "Submit #300367 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.300367"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-26T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-26T10:31:39.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC7 openSchedWifi setSchedWifi stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2901",
"datePublished": "2024-03-26T20:00:06.887Z",
"dateReserved": "2024-03-26T09:26:24.727Z",
"dateUpdated": "2024-08-29T19:09:39.749Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-2900 (GCVE-0-2024-2900)
Vulnerability from cvelistv5 – Published: 2024-03-26 19:31 – Updated: 2024-08-01 19:25
VLAI
EPSS
VEX
Title
Tenda AC7 saveParentControlInfo stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.257943 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.257943 | signaturepermissions-required |
| https://vuldb.com/?submit.300364 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | AC7 |
Affected:
15.03.06.44
|
|
| tenda | ac7_firmware |
Affected:
15.03.06.44
cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac7_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2900",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T18:06:26.520903Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T18:08:23.914Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:25:42.144Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-257943 | Tenda AC7 saveParentControlInfo stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.257943"
},
{
"name": "VDB-257943 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.257943"
},
{
"name": "Submit #300364 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.300364"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_tutu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 gefunden. Dabei betrifft es die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Durch Manipulation des Arguments deviceId/time/urls mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-26T19:31:04.524Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-257943 | Tenda AC7 saveParentControlInfo stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.257943"
},
{
"name": "VDB-257943 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.257943"
},
{
"name": "Submit #300364 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.300364"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-03-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-03-26T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-26T10:31:26.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC7 saveParentControlInfo stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-2900",
"datePublished": "2024-03-26T19:31:04.524Z",
"dateReserved": "2024-03-26T09:26:11.290Z",
"dateUpdated": "2024-08-01T19:25:42.144Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation MIT-10
Operation
Build and Compilation
Strategy: Environment Hardening
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Architecture and Design
Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation
Implementation
Implement and perform bounds checking on input.
Mitigation
Implementation
Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation MIT-11
Operation
Build and Compilation
Strategy: Environment Hardening
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
No CAPEC attack patterns related to this CWE.