Find a vulnerability
Search criteria
286 vulnerabilities by Belkin
CVE-2026-5629 (GCVE-0-2026-5629)
Vulnerability from nvd – Published: 2026-04-06 06:00 – Updated: 2026-04-07 03:02| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355417 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355417/cti | signaturepermissions-required |
| https://vuldb.com/submit/785556 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5629",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-07T03:02:11.977871Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T03:02:58.122Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Belkin F9K1015 1.00.10. The affected element is the function formSetFirewall of the file /goform/formSetFirewall. The manipulation of the argument webpage results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T06:00:18.575Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355417 | Belkin F9K1015 formSetFirewall stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355417"
},
{
"name": "VDB-355417 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355417/cti"
},
{
"name": "Submit #785556 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785556"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_13/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T21:09:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formSetFirewall stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5629",
"datePublished": "2026-04-06T06:00:18.575Z",
"dateReserved": "2026-04-05T19:04:48.555Z",
"dateUpdated": "2026-04-07T03:02:58.122Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5628 (GCVE-0-2026-5628)
Vulnerability from nvd – Published: 2026-04-06 05:30 – Updated: 2026-04-06 12:37| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355416 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355416/cti | signaturepermissions-required |
| https://vuldb.com/submit/785555 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5628",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T12:37:09.110740Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T12:37:23.567Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Setting Handler"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Belkin F9K1015 1.00.10. Impacted is the function formSetSystemSettings of the file /goform/formSetSystemSettings of the component Setting Handler. The manipulation of the argument webpage leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T05:30:12.013Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355416 | Belkin F9K1015 Setting formSetSystemSettings stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355416"
},
{
"name": "VDB-355416 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355416/cti"
},
{
"name": "Submit #785555 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785555"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_12/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T21:09:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 Setting formSetSystemSettings stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5628",
"datePublished": "2026-04-06T05:30:12.013Z",
"dateReserved": "2026-04-05T19:04:45.464Z",
"dateUpdated": "2026-04-06T12:37:23.567Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5614 (GCVE-0-2026-5614)
Vulnerability from nvd – Published: 2026-04-06 02:45 – Updated: 2026-04-06 18:25| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355405 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355405/cti | signaturepermissions-required |
| https://vuldb.com/submit/785554 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5614",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T18:24:57.366841Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T18:25:07.762Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Belkin F9K1015 1.00.10. Impacted is the function formSetPassword of the file /goform/formSetPassword. The manipulation of the argument webpage results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T02:45:10.303Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355405 | Belkin F9K1015 formSetPassword stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355405"
},
{
"name": "VDB-355405 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355405/cti"
},
{
"name": "Submit #785554 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785554"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_11/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:35:15.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formSetPassword stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5614",
"datePublished": "2026-04-06T02:45:10.303Z",
"dateReserved": "2026-04-05T15:29:57.819Z",
"dateUpdated": "2026-04-06T18:25:07.762Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5613 (GCVE-0-2026-5613)
Vulnerability from nvd – Published: 2026-04-06 02:30 – Updated: 2026-04-06 14:49| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355404 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355404/cti | signaturepermissions-required |
| https://vuldb.com/submit/785552 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5613",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T14:41:41.309852Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T14:49:56.235Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Belkin F9K1015 1.00.10. This issue affects the function formReboot of the file /goform/formReboot. The manipulation of the argument webpage leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T02:30:13.584Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355404 | Belkin F9K1015 formReboot stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355404"
},
{
"name": "VDB-355404 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355404/cti"
},
{
"name": "Submit #785552 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785552"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_10/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:35:13.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formReboot stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5613",
"datePublished": "2026-04-06T02:30:13.584Z",
"dateReserved": "2026-04-05T15:29:54.593Z",
"dateUpdated": "2026-04-06T14:49:56.235Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5612 (GCVE-0-2026-5612)
Vulnerability from nvd – Published: 2026-04-06 02:15 – Updated: 2026-04-06 15:03| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355403 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355403/cti | signaturepermissions-required |
| https://vuldb.com/submit/785551 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5612",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T15:03:28.142457Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T15:03:36.906Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Belkin F9K1015 1.00.10. This vulnerability affects the function formWlEncrypt of the file /goform/formWlEncrypt. Executing a manipulation of the argument webpage can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T02:15:09.982Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355403 | Belkin F9K1015 formWlEncrypt stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355403"
},
{
"name": "VDB-355403 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355403/cti"
},
{
"name": "Submit #785551 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785551"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_7/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:35:10.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formWlEncrypt stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5612",
"datePublished": "2026-04-06T02:15:09.982Z",
"dateReserved": "2026-04-05T15:29:51.352Z",
"dateUpdated": "2026-04-06T15:03:36.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5611 (GCVE-0-2026-5611)
Vulnerability from nvd – Published: 2026-04-06 02:00 – Updated: 2026-04-07 02:59| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355402 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355402/cti | signaturepermissions-required |
| https://vuldb.com/submit/785538 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5611",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-07T02:58:23.395786Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T02:59:09.689Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHust (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Belkin F9K1015 1.00.10. This affects the function formCrossBandSwitch of the file /goform/formCrossBandSwitch. Performing a manipulation of the argument webpage results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T02:00:17.506Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355402 | Belkin F9K1015 formCrossBandSwitch stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355402"
},
{
"name": "VDB-355402 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355402/cti"
},
{
"name": "Submit #785538 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785538"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_5/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:35:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formCrossBandSwitch stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5611",
"datePublished": "2026-04-06T02:00:17.506Z",
"dateReserved": "2026-04-05T15:29:48.130Z",
"dateUpdated": "2026-04-07T02:59:09.689Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5610 (GCVE-0-2026-5610)
Vulnerability from nvd – Published: 2026-04-06 01:30 – Updated: 2026-04-06 14:47| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355401 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355401/cti | signaturepermissions-required |
| https://vuldb.com/submit/785537 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5610",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T14:46:51.153797Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T14:47:35.514Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHust (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Belkin F9K1015 1.00.10. Affected by this issue is the function formWISP5G of the file /goform/formWISP5G. Such manipulation of the argument webpage leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T01:30:13.927Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355401 | Belkin F9K1015 formWISP5G stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355401"
},
{
"name": "VDB-355401 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355401/cti"
},
{
"name": "Submit #785537 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785537"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_3/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:35:03.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formWISP5G stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5610",
"datePublished": "2026-04-06T01:30:13.927Z",
"dateReserved": "2026-04-05T15:29:44.472Z",
"dateUpdated": "2026-04-06T14:47:35.514Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5608 (GCVE-0-2026-5608)
Vulnerability from nvd – Published: 2026-04-06 00:30 – Updated: 2026-04-06 14:50| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355399 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355399/cti | signaturepermissions-required |
| https://vuldb.com/submit/785315 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5608",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T14:41:48.413404Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T14:50:03.283Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHust2 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Belkin F9K1122 1.00.33. Affected is the function formWlanSetup of the file /goform/formWlanSetup. The manipulation of the argument webpage results in stack-based buffer overflow. The attack may be performed from remote. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T00:30:10.336Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355399 | Belkin F9K1122 formWlanSetup stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355399"
},
{
"name": "VDB-355399 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355399/cti"
},
{
"name": "Submit #785315 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785315"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_80/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:33:46.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 formWlanSetup stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5608",
"datePublished": "2026-04-06T00:30:10.336Z",
"dateReserved": "2026-04-05T15:22:23.478Z",
"dateUpdated": "2026-04-06T14:50:03.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5044 (GCVE-0-2026-5044)
Vulnerability from nvd – Published: 2026-03-29 12:15 – Updated: 2026-03-30 11:48| URL | Tags |
|---|---|
| https://vuldb.com/vuln/353967 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/353967/cti | signaturepermissions-required |
| https://vuldb.com/submit/779125 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5044",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-30T11:48:13.835585Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-30T11:48:45.133Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Setting Handler"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Belkin F9K1122 1.00.33. This affects the function formSetSystemSettings of the file /goform/formSetSystemSettings of the component Setting Handler. Such manipulation of the argument webpage leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-29T12:15:10.537Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-353967 | Belkin F9K1122 Setting formSetSystemSettings stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/353967"
},
{
"name": "VDB-353967 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/353967/cti"
},
{
"name": "Submit #779125 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/779125"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_155/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-27T17:42:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 Setting formSetSystemSettings stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5044",
"datePublished": "2026-03-29T12:15:10.537Z",
"dateReserved": "2026-03-27T16:35:50.165Z",
"dateUpdated": "2026-03-30T11:48:45.133Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5043 (GCVE-0-2026-5043)
Vulnerability from nvd – Published: 2026-03-29 11:15 – Updated: 2026-03-30 15:56| URL | Tags |
|---|---|
| https://vuldb.com/vuln/353966 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/353966/cti | signaturepermissions-required |
| https://vuldb.com/submit/779124 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5043",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-30T15:56:30.350479Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-30T15:56:42.019Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Parameter Handler"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Belkin F9K1122 1.00.33. The impacted element is the function formSetPassword of the file /goform/formSetPassword of the component Parameter Handler. This manipulation of the argument webpage causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-29T11:15:10.987Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-353966 | Belkin F9K1122 Parameter formSetPassword stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/353966"
},
{
"name": "VDB-353966 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/353966/cti"
},
{
"name": "Submit #779124 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/779124"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_154/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-27T17:41:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 Parameter formSetPassword stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5043",
"datePublished": "2026-03-29T11:15:10.987Z",
"dateReserved": "2026-03-27T16:35:46.876Z",
"dateUpdated": "2026-03-30T15:56:42.019Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5042 (GCVE-0-2026-5042)
Vulnerability from nvd – Published: 2026-03-29 10:30 – Updated: 2026-03-30 14:52| URL | Tags |
|---|---|
| https://vuldb.com/vuln/353965 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/353965/cti | signaturepermissions-required |
| https://vuldb.com/submit/779123 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5042",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-30T12:59:37.583296Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-30T14:52:35.882Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Parameter Handler"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Belkin F9K1122 1.00.33. The affected element is the function formCrossBandSwitch of the file /goform/formCrossBandSwitch of the component Parameter Handler. The manipulation of the argument webpage results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-29T10:30:10.400Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-353965 | Belkin F9K1122 Parameter formCrossBandSwitch stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/353965"
},
{
"name": "VDB-353965 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/353965/cti"
},
{
"name": "Submit #779123 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/779123"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_153/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-27T17:41:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 Parameter formCrossBandSwitch stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5042",
"datePublished": "2026-03-29T10:30:10.400Z",
"dateReserved": "2026-03-27T16:35:43.170Z",
"dateUpdated": "2026-03-30T14:52:35.882Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-4566 (GCVE-0-2026-4566)
Vulnerability from nvd – Published: 2026-03-23 01:30 – Updated: 2026-03-23 16:06| URL | Tags |
|---|---|
| https://vuldb.com/?id.352403 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.352403 | signaturepermissions-required |
| https://vuldb.com/?submit.775132 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | related |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4566",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-23T16:05:50.923506Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-23T16:06:05.262Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHust (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Belkin F9K1122 1.00.33. The affected element is the function formWISP5G of the file /goform/formWISP5G. Executing a manipulation of the argument webpage can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-23T01:30:07.272Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-352403 | Belkin F9K1122 formWISP5G stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.352403"
},
{
"name": "VDB-352403 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.352403"
},
{
"name": "Submit #775132 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.775132"
},
{
"tags": [
"related"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_151/README.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_151/README.md#proof-of-concept-poc"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-22T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-22T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-22T09:36:30.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 formWISP5G stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4566",
"datePublished": "2026-03-23T01:30:07.272Z",
"dateReserved": "2026-03-22T08:31:26.455Z",
"dateUpdated": "2026-03-23T16:06:05.262Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-4167 (GCVE-0-2026-4167)
Vulnerability from nvd – Published: 2026-03-15 05:32 – Updated: 2026-03-17 13:48| URL | Tags |
|---|---|
| https://vuldb.com/?id.351074 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.351074 | signaturepermissions-required |
| https://vuldb.com/?submit.769727 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | related |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4167",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-17T13:48:03.295126Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-17T13:48:43.966Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHust2 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Belkin F9K1122 1.00.33. This affects the function formReboot of the file /goform/formReboot. This manipulation of the argument webpage causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-15T05:32:10.557Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-351074 | Belkin F9K1122 formReboot stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.351074"
},
{
"name": "VDB-351074 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.351074"
},
{
"name": "Submit #769727 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769727"
},
{
"tags": [
"related"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_152/README.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_152/README.md#proof-of-concept-poc"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-14T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-14T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-14T13:37:42.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 formReboot stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4167",
"datePublished": "2026-03-15T05:32:10.557Z",
"dateReserved": "2026-03-14T12:32:38.218Z",
"dateUpdated": "2026-03-17T13:48:43.966Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5629 (GCVE-0-2026-5629)
Vulnerability from cvelistv5 – Published: 2026-04-06 06:00 – Updated: 2026-04-07 03:02| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355417 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355417/cti | signaturepermissions-required |
| https://vuldb.com/submit/785556 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5629",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-07T03:02:11.977871Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T03:02:58.122Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Belkin F9K1015 1.00.10. The affected element is the function formSetFirewall of the file /goform/formSetFirewall. The manipulation of the argument webpage results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T06:00:18.575Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355417 | Belkin F9K1015 formSetFirewall stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355417"
},
{
"name": "VDB-355417 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355417/cti"
},
{
"name": "Submit #785556 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785556"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_13/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T21:09:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formSetFirewall stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5629",
"datePublished": "2026-04-06T06:00:18.575Z",
"dateReserved": "2026-04-05T19:04:48.555Z",
"dateUpdated": "2026-04-07T03:02:58.122Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5628 (GCVE-0-2026-5628)
Vulnerability from cvelistv5 – Published: 2026-04-06 05:30 – Updated: 2026-04-06 12:37| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355416 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355416/cti | signaturepermissions-required |
| https://vuldb.com/submit/785555 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5628",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T12:37:09.110740Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T12:37:23.567Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Setting Handler"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Belkin F9K1015 1.00.10. Impacted is the function formSetSystemSettings of the file /goform/formSetSystemSettings of the component Setting Handler. The manipulation of the argument webpage leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T05:30:12.013Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355416 | Belkin F9K1015 Setting formSetSystemSettings stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355416"
},
{
"name": "VDB-355416 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355416/cti"
},
{
"name": "Submit #785555 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785555"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_12/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T21:09:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 Setting formSetSystemSettings stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5628",
"datePublished": "2026-04-06T05:30:12.013Z",
"dateReserved": "2026-04-05T19:04:45.464Z",
"dateUpdated": "2026-04-06T12:37:23.567Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5614 (GCVE-0-2026-5614)
Vulnerability from cvelistv5 – Published: 2026-04-06 02:45 – Updated: 2026-04-06 18:25| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355405 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355405/cti | signaturepermissions-required |
| https://vuldb.com/submit/785554 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5614",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T18:24:57.366841Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T18:25:07.762Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Belkin F9K1015 1.00.10. Impacted is the function formSetPassword of the file /goform/formSetPassword. The manipulation of the argument webpage results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T02:45:10.303Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355405 | Belkin F9K1015 formSetPassword stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355405"
},
{
"name": "VDB-355405 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355405/cti"
},
{
"name": "Submit #785554 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785554"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_11/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:35:15.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formSetPassword stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5614",
"datePublished": "2026-04-06T02:45:10.303Z",
"dateReserved": "2026-04-05T15:29:57.819Z",
"dateUpdated": "2026-04-06T18:25:07.762Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5613 (GCVE-0-2026-5613)
Vulnerability from cvelistv5 – Published: 2026-04-06 02:30 – Updated: 2026-04-06 14:49| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355404 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355404/cti | signaturepermissions-required |
| https://vuldb.com/submit/785552 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5613",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T14:41:41.309852Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T14:49:56.235Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Belkin F9K1015 1.00.10. This issue affects the function formReboot of the file /goform/formReboot. The manipulation of the argument webpage leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T02:30:13.584Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355404 | Belkin F9K1015 formReboot stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355404"
},
{
"name": "VDB-355404 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355404/cti"
},
{
"name": "Submit #785552 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785552"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_10/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:35:13.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formReboot stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5613",
"datePublished": "2026-04-06T02:30:13.584Z",
"dateReserved": "2026-04-05T15:29:54.593Z",
"dateUpdated": "2026-04-06T14:49:56.235Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5612 (GCVE-0-2026-5612)
Vulnerability from cvelistv5 – Published: 2026-04-06 02:15 – Updated: 2026-04-06 15:03| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355403 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355403/cti | signaturepermissions-required |
| https://vuldb.com/submit/785551 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5612",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T15:03:28.142457Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T15:03:36.906Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Belkin F9K1015 1.00.10. This vulnerability affects the function formWlEncrypt of the file /goform/formWlEncrypt. Executing a manipulation of the argument webpage can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T02:15:09.982Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355403 | Belkin F9K1015 formWlEncrypt stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355403"
},
{
"name": "VDB-355403 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355403/cti"
},
{
"name": "Submit #785551 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785551"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_7/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:35:10.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formWlEncrypt stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5612",
"datePublished": "2026-04-06T02:15:09.982Z",
"dateReserved": "2026-04-05T15:29:51.352Z",
"dateUpdated": "2026-04-06T15:03:36.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5611 (GCVE-0-2026-5611)
Vulnerability from cvelistv5 – Published: 2026-04-06 02:00 – Updated: 2026-04-07 02:59| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355402 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355402/cti | signaturepermissions-required |
| https://vuldb.com/submit/785538 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5611",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-07T02:58:23.395786Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-07T02:59:09.689Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHust (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Belkin F9K1015 1.00.10. This affects the function formCrossBandSwitch of the file /goform/formCrossBandSwitch. Performing a manipulation of the argument webpage results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T02:00:17.506Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355402 | Belkin F9K1015 formCrossBandSwitch stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355402"
},
{
"name": "VDB-355402 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355402/cti"
},
{
"name": "Submit #785538 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785538"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_5/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:35:06.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formCrossBandSwitch stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5611",
"datePublished": "2026-04-06T02:00:17.506Z",
"dateReserved": "2026-04-05T15:29:48.130Z",
"dateUpdated": "2026-04-07T02:59:09.689Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5610 (GCVE-0-2026-5610)
Vulnerability from cvelistv5 – Published: 2026-04-06 01:30 – Updated: 2026-04-06 14:47| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355401 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355401/cti | signaturepermissions-required |
| https://vuldb.com/submit/785537 | third-party-advisory |
| https://github.com/Litengzheng/vuldb_new/blob/mai… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5610",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T14:46:51.153797Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T14:47:35.514Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1015_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1015",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.10"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHust (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Belkin F9K1015 1.00.10. Affected by this issue is the function formWISP5G of the file /goform/formWISP5G. Such manipulation of the argument webpage leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T01:30:13.927Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355401 | Belkin F9K1015 formWISP5G stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355401"
},
{
"name": "VDB-355401 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355401/cti"
},
{
"name": "Submit #785537 | Belkin F9K1015 1.00.10 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785537"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vuldb_new/blob/main/Belkin%20F9K1015/vul_3/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:35:03.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1015 formWISP5G stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5610",
"datePublished": "2026-04-06T01:30:13.927Z",
"dateReserved": "2026-04-05T15:29:44.472Z",
"dateUpdated": "2026-04-06T14:47:35.514Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5608 (GCVE-0-2026-5608)
Vulnerability from cvelistv5 – Published: 2026-04-06 00:30 – Updated: 2026-04-06 14:50| URL | Tags |
|---|---|
| https://vuldb.com/vuln/355399 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/355399/cti | signaturepermissions-required |
| https://vuldb.com/submit/785315 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5608",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-06T14:41:48.413404Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T14:50:03.283Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHust2 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB CNA Team"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Belkin F9K1122 1.00.33. Affected is the function formWlanSetup of the file /goform/formWlanSetup. The manipulation of the argument webpage results in stack-based buffer overflow. The attack may be performed from remote. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-06T00:30:10.336Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-355399 | Belkin F9K1122 formWlanSetup stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/355399"
},
{
"name": "VDB-355399 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/355399/cti"
},
{
"name": "Submit #785315 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/785315"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_80/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-04-05T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-04-05T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-04-05T17:33:46.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 formWlanSetup stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5608",
"datePublished": "2026-04-06T00:30:10.336Z",
"dateReserved": "2026-04-05T15:22:23.478Z",
"dateUpdated": "2026-04-06T14:50:03.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5044 (GCVE-0-2026-5044)
Vulnerability from cvelistv5 – Published: 2026-03-29 12:15 – Updated: 2026-03-30 11:48| URL | Tags |
|---|---|
| https://vuldb.com/vuln/353967 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/353967/cti | signaturepermissions-required |
| https://vuldb.com/submit/779125 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5044",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-30T11:48:13.835585Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-30T11:48:45.133Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Setting Handler"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Belkin F9K1122 1.00.33. This affects the function formSetSystemSettings of the file /goform/formSetSystemSettings of the component Setting Handler. Such manipulation of the argument webpage leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-29T12:15:10.537Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-353967 | Belkin F9K1122 Setting formSetSystemSettings stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/353967"
},
{
"name": "VDB-353967 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/353967/cti"
},
{
"name": "Submit #779125 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/779125"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_155/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-27T17:42:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 Setting formSetSystemSettings stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5044",
"datePublished": "2026-03-29T12:15:10.537Z",
"dateReserved": "2026-03-27T16:35:50.165Z",
"dateUpdated": "2026-03-30T11:48:45.133Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5043 (GCVE-0-2026-5043)
Vulnerability from cvelistv5 – Published: 2026-03-29 11:15 – Updated: 2026-03-30 15:56| URL | Tags |
|---|---|
| https://vuldb.com/vuln/353966 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/353966/cti | signaturepermissions-required |
| https://vuldb.com/submit/779124 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5043",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-30T15:56:30.350479Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-30T15:56:42.019Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Parameter Handler"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Belkin F9K1122 1.00.33. The impacted element is the function formSetPassword of the file /goform/formSetPassword of the component Parameter Handler. This manipulation of the argument webpage causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-29T11:15:10.987Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-353966 | Belkin F9K1122 Parameter formSetPassword stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/353966"
},
{
"name": "VDB-353966 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/353966/cti"
},
{
"name": "Submit #779124 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/779124"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_154/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-27T17:41:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 Parameter formSetPassword stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5043",
"datePublished": "2026-03-29T11:15:10.987Z",
"dateReserved": "2026-03-27T16:35:46.876Z",
"dateUpdated": "2026-03-30T15:56:42.019Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-5042 (GCVE-0-2026-5042)
Vulnerability from cvelistv5 – Published: 2026-03-29 10:30 – Updated: 2026-03-30 14:52| URL | Tags |
|---|---|
| https://vuldb.com/vuln/353965 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/353965/cti | signaturepermissions-required |
| https://vuldb.com/submit/779123 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-5042",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-30T12:59:37.583296Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-30T14:52:35.882Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"modules": [
"Parameter Handler"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHuster2 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Belkin F9K1122 1.00.33. The affected element is the function formCrossBandSwitch of the file /goform/formCrossBandSwitch of the component Parameter Handler. The manipulation of the argument webpage results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-29T10:30:10.400Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-353965 | Belkin F9K1122 Parameter formCrossBandSwitch stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/353965"
},
{
"name": "VDB-353965 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/353965/cti"
},
{
"name": "Submit #779123 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/779123"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_153/README.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-27T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-27T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-27T17:41:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 Parameter formCrossBandSwitch stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-5042",
"datePublished": "2026-03-29T10:30:10.400Z",
"dateReserved": "2026-03-27T16:35:43.170Z",
"dateUpdated": "2026-03-30T14:52:35.882Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-4566 (GCVE-0-2026-4566)
Vulnerability from cvelistv5 – Published: 2026-03-23 01:30 – Updated: 2026-03-23 16:06| URL | Tags |
|---|---|
| https://vuldb.com/?id.352403 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.352403 | signaturepermissions-required |
| https://vuldb.com/?submit.775132 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | related |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4566",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-23T16:05:50.923506Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-23T16:06:05.262Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHust (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Belkin F9K1122 1.00.33. The affected element is the function formWISP5G of the file /goform/formWISP5G. Executing a manipulation of the argument webpage can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-23T01:30:07.272Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-352403 | Belkin F9K1122 formWISP5G stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.352403"
},
{
"name": "VDB-352403 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.352403"
},
{
"name": "Submit #775132 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.775132"
},
{
"tags": [
"related"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_151/README.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_151/README.md#proof-of-concept-poc"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-22T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-22T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-22T09:36:30.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 formWISP5G stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4566",
"datePublished": "2026-03-23T01:30:07.272Z",
"dateReserved": "2026-03-22T08:31:26.455Z",
"dateUpdated": "2026-03-23T16:06:05.262Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-4167 (GCVE-0-2026-4167)
Vulnerability from cvelistv5 – Published: 2026-03-15 05:32 – Updated: 2026-03-17 13:48| URL | Tags |
|---|---|
| https://vuldb.com/?id.351074 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.351074 | signaturepermissions-required |
| https://vuldb.com/?submit.769727 | third-party-advisory |
| https://github.com/Litengzheng/vul_db/blob/main/B… | related |
| https://github.com/Litengzheng/vul_db/blob/main/B… | exploit |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-4167",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-17T13:48:03.295126Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-17T13:48:43.966Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:belkin:f9k1122_firmware:*:*:*:*:*:*:*:*"
],
"product": "F9K1122",
"vendor": "Belkin",
"versions": [
{
"status": "affected",
"version": "1.00.33"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LtzHust2 (VulDB User)"
},
{
"lang": "en",
"type": "coordinator",
"value": "VulDB"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Belkin F9K1122 1.00.33. This affects the function formReboot of the file /goform/formReboot. This manipulation of the argument webpage causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-15T05:32:10.557Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-351074 | Belkin F9K1122 formReboot stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.351074"
},
{
"name": "VDB-351074 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.351074"
},
{
"name": "Submit #769727 | Belkin F9K1122 1.00.33 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.769727"
},
{
"tags": [
"related"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_152/README.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Litengzheng/vul_db/blob/main/Belkin/vul_152/README.md#proof-of-concept-poc"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-03-14T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-03-14T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-03-14T13:37:42.000Z",
"value": "VulDB entry last update"
}
],
"title": "Belkin F9K1122 formReboot stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-4167",
"datePublished": "2026-03-15T05:32:10.557Z",
"dateReserved": "2026-03-14T12:32:38.218Z",
"dateUpdated": "2026-03-17T13:48:43.966Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
VAR-202508-0193
Vulnerability from variot - Updated: 2025-10-10 23:41A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. The Belkin F9K1009 and Belkin F9K1010 are both wireless routers manufactured by Belkin, a Canadian company.
The Belkin F9K1009 and Belkin F9K1010 have a hardcoded credential vulnerability that could allow an attacker to gain access to the devices
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202508-0193",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "f9k1009",
"scope": "eq",
"trust": 0.6,
"vendor": "belkin",
"version": "2.00.04"
},
{
"model": "f9k1009",
"scope": "eq",
"trust": 0.6,
"vendor": "belkin",
"version": "2.00.09"
},
{
"model": "f9k1010",
"scope": "eq",
"trust": 0.6,
"vendor": "belkin",
"version": "2.00.04"
},
{
"model": "f9k1010",
"scope": "eq",
"trust": 0.6,
"vendor": "belkin",
"version": "2.00.09"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23130"
}
]
},
"cve": "CVE-2025-8730",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2025-8730",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-23130",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-8730",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-8730",
"trust": 1.0,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-23130",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23130"
},
{
"db": "NVD",
"id": "CVE-2025-8730"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. The Belkin F9K1009 and Belkin F9K1010 are both wireless routers manufactured by Belkin, a Canadian company. \n\nThe Belkin F9K1009 and Belkin F9K1010 have a hardcoded credential vulnerability that could allow an attacker to gain access to the devices",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-8730"
},
{
"db": "CNVD",
"id": "CNVD-2025-23130"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-8730",
"trust": 1.6
},
{
"db": "VULDB",
"id": "319226",
"trust": 1.0
},
{
"db": "CNVD",
"id": "CNVD-2025-23130",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23130"
},
{
"db": "NVD",
"id": "CVE-2025-8730"
}
]
},
"id": "VAR-202508-0193",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23130"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23130"
}
]
},
"last_update_date": "2025-10-10T23:41:48.815000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Belkin F9K1009 and Belkin F9K1010 Hardcoded Credentials Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/740561"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23130"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "CWE-259",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2025-8730"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://github.com/nicholas-wei/bug-discovery/blob/main/belkin/f9k1009_ww_2.00.09/belkin%20f9k1009_ww_2.00.09_hardcoded_credential.pdf"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?id.319226"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?submit.621760"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?submit.621747"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.319226"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?submit.621748"
},
{
"trust": 1.0,
"url": "https://github.com/nicholas-wei/bug-discovery/blob/main/belkin/f9k1010_ww_2.00.04/belkin_f9k1010_ww_2.00.04_hardcoded_credential.pdf"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-8730"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23130"
},
{
"db": "NVD",
"id": "CVE-2025-8730"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-23130"
},
{
"db": "NVD",
"id": "CVE-2025-8730"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-23130"
},
{
"date": "2025-08-08T15:15:29.217000",
"db": "NVD",
"id": "CVE-2025-8730"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-23130"
},
{
"date": "2025-08-08T20:30:18.180000",
"db": "NVD",
"id": "CVE-2025-8730"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Belkin F9K1009 and Belkin F9K1010 Hardcoded Credentials Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23130"
}
],
"trust": 0.6
}
}
VAR-202508-0372
Vulnerability from variot - Updated: 2025-09-28 03:29A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function RP_setBasic of the file /goform/RP_setBasic. The manipulation of the argument bssid leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. Linksys of RE6250 Firmware and other products from multiple vendors have command injection vulnerabilities, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202508-0372",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "re9000",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.04.002"
},
{
"model": "re6250",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.04.001"
},
{
"model": "re6500",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.013.001"
},
{
"model": "re7000",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.1.05.003"
},
{
"model": "re6300",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.2.07.001"
},
{
"model": "re6350",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.04.001"
},
{
"model": "re9000",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6250",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6300",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re7000",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6350",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6500",
"scope": null,
"trust": 0.8,
"vendor": "belkin",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014462"
},
{
"db": "NVD",
"id": "CVE-2025-8821"
}
]
},
"cve": "CVE-2025-8821",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2025-8821",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Partial",
"baseScore": 6.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2025-014462",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"id": "CVE-2025-8821",
"impactScore": 3.4,
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-8821",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-014462",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-8821",
"trust": 1.0,
"value": "Low"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2025-8821",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2025-014462",
"trust": 0.8,
"value": "High"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014462"
},
{
"db": "NVD",
"id": "CVE-2025-8821"
},
{
"db": "NVD",
"id": "CVE-2025-8821"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function RP_setBasic of the file /goform/RP_setBasic. The manipulation of the argument bssid leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. Linksys of RE6250 Firmware and other products from multiple vendors have command injection vulnerabilities, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-8821"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014462"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-8821",
"trust": 2.6
},
{
"db": "VULDB",
"id": "319355",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014462",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014462"
},
{
"db": "NVD",
"id": "CVE-2025-8821"
}
]
},
"id": "VAR-202508-0372",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.675
},
"last_update_date": "2025-09-28T03:29:47.787000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.0
},
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "Command injection (CWE-77) [ others ]",
"trust": 0.8
},
{
"problemtype": "OS Command injection (CWE-78) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014462"
},
{
"db": "NVD",
"id": "CVE-2025-8821"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/wudipjq/my_vuln/blob/main/linksys1/vuln_55/55.md"
},
{
"trust": 1.8,
"url": "https://github.com/wudipjq/my_vuln/blob/main/linksys1/vuln_55/55.md#poc"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.319355"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.626685"
},
{
"trust": 1.8,
"url": "https://www.linksys.com/"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.319355"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-8821"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014462"
},
{
"db": "NVD",
"id": "CVE-2025-8821"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014462"
},
{
"db": "NVD",
"id": "CVE-2025-8821"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014462"
},
{
"date": "2025-08-11T01:15:28.510000",
"db": "NVD",
"id": "CVE-2025-8821"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-25T08:21:00",
"db": "JVNDB",
"id": "JVNDB-2025-014462"
},
{
"date": "2025-09-04T18:39:31.073000",
"db": "NVD",
"id": "CVE-2025-8821"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Linksys\u00a0 of \u00a0RE6250\u00a0 Command injection vulnerabilities in firmware and other products from multiple vendors",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014462"
}
],
"trust": 0.8
}
}
VAR-202508-0364
Vulnerability from variot - Updated: 2025-09-28 03:25A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setRIP of the file /goform/setRIP. The manipulation of the argument RIPmode/RIPpasswd leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. Linksys of RE6250 Firmware and other products from multiple vendors contain buffer error vulnerabilities and stack-based buffer overflow vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202508-0364",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "re9000",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.04.002"
},
{
"model": "re6250",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.04.001"
},
{
"model": "re6500",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.013.001"
},
{
"model": "re7000",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.1.05.003"
},
{
"model": "re6300",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.2.07.001"
},
{
"model": "re6350",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.04.001"
},
{
"model": "re9000",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6250",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6300",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re7000",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6350",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6500",
"scope": null,
"trust": 0.8,
"vendor": "belkin",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014463"
},
{
"db": "NVD",
"id": "CVE-2025-8824"
}
]
},
"cve": "CVE-2025-8824",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2025-8824",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2025-014463",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-8824",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-014463",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-8824",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2025-014463",
"trust": 0.8,
"value": "High"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014463"
},
{
"db": "NVD",
"id": "CVE-2025-8824"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setRIP of the file /goform/setRIP. The manipulation of the argument RIPmode/RIPpasswd leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. Linksys of RE6250 Firmware and other products from multiple vendors contain buffer error vulnerabilities and stack-based buffer overflow vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-8824"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014463"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-8824",
"trust": 2.6
},
{
"db": "VULDB",
"id": "319358",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014463",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014463"
},
{
"db": "NVD",
"id": "CVE-2025-8824"
}
]
},
"id": "VAR-202508-0364",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.675
},
"last_update_date": "2025-09-28T03:25:45.461000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014463"
},
{
"db": "NVD",
"id": "CVE-2025-8824"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/wudipjq/my_vuln/blob/main/linksys1/vuln_40/40.md"
},
{
"trust": 1.8,
"url": "https://github.com/wudipjq/my_vuln/blob/main/linksys1/vuln_40/40.md#poc"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?ctiid.319358"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.319358"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.626689"
},
{
"trust": 1.8,
"url": "https://www.linksys.com/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-8824"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014463"
},
{
"db": "NVD",
"id": "CVE-2025-8824"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014463"
},
{
"db": "NVD",
"id": "CVE-2025-8824"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014463"
},
{
"date": "2025-08-11T02:15:26.023000",
"db": "NVD",
"id": "CVE-2025-8824"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-25T08:22:00",
"db": "JVNDB",
"id": "JVNDB-2025-014463"
},
{
"date": "2025-09-04T18:38:17.313000",
"db": "NVD",
"id": "CVE-2025-8824"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Linksys\u00a0 of \u00a0RE6250\u00a0 Buffer error vulnerabilities in firmware and other products from multiple vendors",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014463"
}
],
"trust": 0.8
}
}
VAR-202508-0331
Vulnerability from variot - Updated: 2025-09-28 03:19A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function setWan of the file /goform/setWan. The manipulation of the argument staticIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. Linksys of RE6250 Firmware and other products from multiple vendors contain buffer error vulnerabilities and stack-based buffer overflow vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202508-0331",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "re9000",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.04.002"
},
{
"model": "re6250",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.04.001"
},
{
"model": "re6500",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.013.001"
},
{
"model": "re7000",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.1.05.003"
},
{
"model": "re6300",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.2.07.001"
},
{
"model": "re6350",
"scope": "eq",
"trust": 1.0,
"vendor": "linksys",
"version": "1.0.04.001"
},
{
"model": "re9000",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6250",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6300",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re7000",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6350",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "re6500",
"scope": null,
"trust": 0.8,
"vendor": "belkin",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014461"
},
{
"db": "NVD",
"id": "CVE-2025-8819"
}
]
},
"cve": "CVE-2025-8819",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2025-8819",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2025-014461",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-8819",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-014461",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-8819",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2025-014461",
"trust": 0.8,
"value": "High"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014461"
},
{
"db": "NVD",
"id": "CVE-2025-8819"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function setWan of the file /goform/setWan. The manipulation of the argument staticIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. Linksys of RE6250 Firmware and other products from multiple vendors contain buffer error vulnerabilities and stack-based buffer overflow vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-8819"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014461"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-8819",
"trust": 2.6
},
{
"db": "VULDB",
"id": "319353",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014461",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014461"
},
{
"db": "NVD",
"id": "CVE-2025-8819"
}
]
},
"id": "VAR-202508-0331",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.675
},
"last_update_date": "2025-09-28T03:19:11.346000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014461"
},
{
"db": "NVD",
"id": "CVE-2025-8819"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/wudipjq/my_vuln/blob/main/linksys1/vuln_53/53.md"
},
{
"trust": 1.8,
"url": "https://github.com/wudipjq/my_vuln/blob/main/linksys1/vuln_53/53.md#poc"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.319353"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.626683"
},
{
"trust": 1.8,
"url": "https://www.linksys.com/"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.319353"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-8819"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014461"
},
{
"db": "NVD",
"id": "CVE-2025-8819"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014461"
},
{
"db": "NVD",
"id": "CVE-2025-8819"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014461"
},
{
"date": "2025-08-10T23:15:26.607000",
"db": "NVD",
"id": "CVE-2025-8819"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-25T08:19:00",
"db": "JVNDB",
"id": "JVNDB-2025-014461"
},
{
"date": "2025-09-04T18:40:56.497000",
"db": "NVD",
"id": "CVE-2025-8819"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Linksys\u00a0 of \u00a0RE6250\u00a0 Buffer error vulnerabilities in firmware and other products from multiple vendors",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014461"
}
],
"trust": 0.8
}
}