VDE-2023-011
Vulnerability from csaf_frauschersensortechnikgmbh - Published: 2023-07-05 08:00 - Updated: 2023-07-05 08:00Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Diagnostic System FDS101 for FAdC/FAdCi <=1.3.3
Frauscher / Software / Diagnostic System FDS101 for FAdC/FAdCi
|
<=1.3.3 |
Mitigation
No Fix Planned
|
| URL | Category |
|---|---|
| https://certvde.com/en/advisories/VDE-2023-011/ | self |
| https://frauscher.csaf-tp.certvde.com/.well-known… | self |
| https://www.frauscher.com | external |
| https://certvde.com/en/advisories/vendor/frauscher/ | external |
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination",
"urls": [
"https://certvde.com"
]
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "Frauscher Diagnostic System FDS001 for FAdC R1 and FAdCi R1 v1.3.3 and all previous versions are vulnerable to a\u00a0path traversal vulnerability of the web interface by a crafted URL without authentication.",
"title": "Summary"
},
{
"category": "description",
"text": "The attacker can read all files on the filesystem of the FDS001 device. Note: Orphaned SSH keys exist on the file system, but they cannot be used to log in to the machine.",
"title": "Impact"
},
{
"category": "description",
"text": "Security-related application conditions SecRACThe railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS001.The recommendation is to connect the Frauscher Diagnostic System FDS001 to a network of category 2. If the Frauscher Diagnostic System FDS001 is connected to a network of category 3 (according to EN 50159:2010), then additional protective measures must be added.",
"title": "Mitigation"
},
{
"category": "description",
"text": "For the Frauscher Diagnostic System FDS001 for FAdC R1 and FAdCi R1 no more firmware updates will be provided.",
"title": "Remediation"
}
],
"publisher": {
"category": "vendor",
"contact_details": "psirt@frauscher.com",
"name": "Frauscher Sensortechnik GmbH",
"namespace": "https://www.frauscher.com"
},
"references": [
{
"category": "self",
"summary": "VDE-2023-011: Frauscher: Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability - HTML",
"url": "https://certvde.com/en/advisories/VDE-2023-011/"
},
{
"category": "self",
"summary": "VDE-2023-011: Frauscher: Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability - CSAF",
"url": "https://frauscher.csaf-tp.certvde.com/.well-known/csaf/white/2023/vde-2023-011.json"
},
{
"category": "external",
"summary": "Vendor PSIRT",
"url": "https://www.frauscher.com"
},
{
"category": "external",
"summary": "CERT@VDE Security Advisories for Frauscher Sensortechnik GmbH",
"url": "https://certvde.com/en/advisories/vendor/frauscher/"
}
],
"title": "Frauscher: Diagnostic System FDS001 for FAdC/FAdCi Path Traversal vulnerability",
"tracking": {
"aliases": [
"VDE-2023-011"
],
"current_release_date": "2023-07-05T08:00:00.000Z",
"generator": {
"date": "2025-04-29T17:20:57.199Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.24"
}
},
"id": "VDE-2023-011",
"initial_release_date": "2023-07-05T08:00:00.000Z",
"revision_history": [
{
"date": "2023-07-05T08:00:00.000Z",
"number": "1",
"summary": "Initial revision."
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=1.3.3",
"product": {
"name": "Diagnostic System FDS101 for FAdC/FAdCi \u003c=1.3.3",
"product_id": "CSAFPID-51001"
}
}
],
"category": "product_name",
"name": "Diagnostic System FDS101 for FAdC/FAdCi"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "Frauscher"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-2880",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "Frauscher Sensortechnik GmbH FDS001 for FAdC/FAdCi v1.3.3 and all previous versions are vulnerable to a path traversal vulnerability of the web interface by a crafted URL without authentication. This enables an remote attacker to read all files on the filesystem of the FDS001 device.",
"title": "Vulnerability Description"
}
],
"product_status": {
"known_affected": [
"CSAFPID-51001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Security-related application conditions SecRACThe railway operator must ensure that only authorised personnel or people in the company of authorised personnel have access to the Frauscher Diagnostic System FDS001.The recommendation is to connect the Frauscher Diagnostic System FDS001 to a network of category 2. If the Frauscher Diagnostic System FDS001 is connected to a network of category 3 (according to EN 50159:2010), then additional protective measures must be added.\n\nFor the Frauscher Diagnostic System FDS001 for FAdC R1 and FAdCi R1 no more firmware updates will be provided.",
"product_ids": [
"CSAFPID-51001"
]
},
{
"category": "no_fix_planned",
"details": "For the Frauscher Diagnostic System FDS001 for FAdC R1 and FAdCi R1 no more firmware updates will be provided.\n\n",
"product_ids": [
"CSAFPID-51001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-51001"
]
}
],
"title": "CVE-2023-2880"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.