VAR-202509-3042
Vulnerability from variot - Updated: 2025-10-03 23:32Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics DIALink. Authentication is not required to exploit this vulnerability.The specific flaw exists within the DataCenter service, which listens on TCP port 7631 by default. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Delta Electronics DIALink is an industrial automation communication gateway from Delta Electronics, a Chinese company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202509-3042",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "dialink",
"scope": "lt",
"trust": 1.0,
"vendor": "deltaww",
"version": "1.8.0.0"
},
{
"model": "dialink",
"scope": null,
"trust": 0.7,
"vendor": "delta",
"version": null
},
{
"model": "electronics dialink",
"scope": "lte",
"trust": 0.6,
"vendor": "delta",
"version": "\u003c=1.6.0.0"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-926"
},
{
"db": "CNVD",
"id": "CNVD-2025-22948"
},
{
"db": "NVD",
"id": "CVE-2025-58321"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Anonymous",
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-926"
}
],
"trust": 0.7
},
"cve": "CVE-2025-58321",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-22948",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-58321",
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-58321",
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "759f5e80-c8e1-4224-bead-956d7b33c98b",
"id": "CVE-2025-58321",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "ZDI",
"id": "CVE-2025-58321",
"trust": 0.7,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2025-22948",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-926"
},
{
"db": "CNVD",
"id": "CNVD-2025-22948"
},
{
"db": "NVD",
"id": "CVE-2025-58321"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics DIALink. Authentication is not required to exploit this vulnerability.The specific flaw exists within the DataCenter service, which listens on TCP port 7631 by default. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Delta Electronics DIALink is an industrial automation communication gateway from Delta Electronics, a Chinese company",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-58321"
},
{
"db": "ZDI",
"id": "ZDI-25-926"
},
{
"db": "CNVD",
"id": "CNVD-2025-22948"
}
],
"trust": 2.07
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-58321",
"trust": 2.3
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-26827",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-25-926",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2025-22948",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-926"
},
{
"db": "CNVD",
"id": "CNVD-2025-22948"
},
{
"db": "NVD",
"id": "CVE-2025-58321"
}
]
},
"id": "VAR-202509-3042",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-22948"
}
],
"trust": 1.2926407
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-22948"
}
]
},
"last_update_date": "2025-10-03T23:32:49.250000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Delta Electronics has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-259-07"
},
{
"title": "Patch for Delta Electronics DIALink Directory Traversal Vulnerability (CNVD-2025-22948)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/738711"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-926"
},
{
"db": "CNVD",
"id": "CNVD-2025-22948"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-22",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2025-58321"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://filecenter.deltaww.com/news/download/doc/delta-pcsa-2025-00016_dialink%20-%20directory%20traversal%20authentication%20bypass%20vulnerability.pdf"
},
{
"trust": 0.7,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-259-07"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-926"
},
{
"db": "CNVD",
"id": "CNVD-2025-22948"
},
{
"db": "NVD",
"id": "CVE-2025-58321"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-25-926"
},
{
"db": "CNVD",
"id": "CNVD-2025-22948"
},
{
"db": "NVD",
"id": "CVE-2025-58321"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-01T00:00:00",
"db": "ZDI",
"id": "ZDI-25-926"
},
{
"date": "2025-09-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-22948"
},
{
"date": "2025-09-11T09:15:35.010000",
"db": "NVD",
"id": "CVE-2025-58321"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-01T00:00:00",
"db": "ZDI",
"id": "ZDI-25-926"
},
{
"date": "2025-09-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-22948"
},
{
"date": "2025-09-26T14:43:15.530000",
"db": "NVD",
"id": "CVE-2025-58321"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Delta Electronics DIALink Directory Traversal Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-926"
}
],
"trust": 0.7
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…