VAR-202509-0089
Vulnerability from variot - Updated: 2025-10-03 23:20A vulnerability was determined in Tenda CP6 11.10.00.243. The affected element is the function sub_2B7D04 of the component uhttp. Executing manipulation can lead to risky cryptographic algorithm. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is described as difficult. The exploit has been publicly disclosed and may be utilized. The Tenda CP6 is a smart camera from the Chinese company Tenda. This vulnerability stems from the use of a compromised encryption algorithm in the function sub_2B7D04 in the uhttp component. An attacker could exploit this vulnerability to compromise the device's integrity
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202509-0089",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "cp6",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "11.10.00.243"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21171"
},
{
"db": "NVD",
"id": "CVE-2025-9828"
}
]
},
"cve": "CVE-2025-9828",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "cna@vuldb.com",
"availabilityImpact": "NONE",
"baseScore": 2.6,
"confidentialityImpact": "NONE",
"exploitabilityScore": 4.9,
"id": "CVE-2025-9828",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 1.0,
"vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 2.6,
"confidentialityImpact": "NONE",
"exploitabilityScore": 4.9,
"id": "CNVD-2025-21171",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:N/AC:H/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.2,
"id": "CVE-2025-9828",
"impactScore": 1.4,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.2,
"id": "CVE-2025-9828",
"impactScore": 3.6,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-9828",
"trust": 1.0,
"value": "Low"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2025-9828",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2025-21171",
"trust": 0.6,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21171"
},
{
"db": "NVD",
"id": "CVE-2025-9828"
},
{
"db": "NVD",
"id": "CVE-2025-9828"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was determined in Tenda CP6 11.10.00.243. The affected element is the function sub_2B7D04 of the component uhttp. Executing manipulation can lead to risky cryptographic algorithm. The attack may be launched remotely. This attack is characterized by high complexity. The exploitability is described as difficult. The exploit has been publicly disclosed and may be utilized. The Tenda CP6 is a smart camera from the Chinese company Tenda. This vulnerability stems from the use of a compromised encryption algorithm in the function sub_2B7D04 in the uhttp component. An attacker could exploit this vulnerability to compromise the device\u0027s integrity",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-9828"
},
{
"db": "CNVD",
"id": "CNVD-2025-21171"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-9828",
"trust": 1.6
},
{
"db": "VULDB",
"id": "322175",
"trust": 1.0
},
{
"db": "CNVD",
"id": "CNVD-2025-21171",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21171"
},
{
"db": "NVD",
"id": "CVE-2025-9828"
}
]
},
"id": "VAR-202509-0089",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21171"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21171"
}
]
},
"last_update_date": "2025-10-03T23:20:57.695000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-327",
"trust": 1.0
},
{
"problemtype": "CWE-310",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2025-9828"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.0,
"url": "https://github.com/iotres/iot_firmware_update/blob/main/tenda/cp6.md"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.322175"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?submit.641566"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?id.322175"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-9828"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21171"
},
{
"db": "NVD",
"id": "CVE-2025-9828"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-21171"
},
{
"db": "NVD",
"id": "CVE-2025-9828"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-21171"
},
{
"date": "2025-09-02T17:15:36.740000",
"db": "NVD",
"id": "CVE-2025-9828"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-21171"
},
{
"date": "2025-10-03T15:05:39.963000",
"db": "NVD",
"id": "CVE-2025-9828"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda CP6 encryption vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21171"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.