VAR-202406-2615

Vulnerability from variot - Updated: 2025-06-01 23:09

Insecure permissions in Netgear WNR614 JNR1010V2/N300-V1.1.0.54_1.0.1 allows attackers to access URLs and directories embedded within the firmware via unspecified vectors. of netgear WNR614 A path traversal vulnerability exists in firmware.Information may be tampered with. NETGEAR WNR614 is an N300 wireless router with an external antenna from NETGEAR Inc. Attackers can exploit this vulnerability to cause information leakage

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202406-2615",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "wnr614",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netgear",
        "version": "1.1.0.54_1.0.1"
      },
      {
        "model": "wnr614",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "wnr614",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": null
      },
      {
        "model": "wnr614",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
        "version": "wnr614  firmware  1.1.0.54 1.0.1"
      },
      {
        "model": "wnr614 v1.1.0.54 1.0.1",
        "scope": null,
        "trust": 0.6,
        "vendor": "netgear",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10687"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024408"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-36795"
      }
    ]
  },
  "cve": "CVE-2024-36795",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2025-10687",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "NONE",
            "baseScore": 4.0,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.5,
            "id": "CVE-2024-36795",
            "impactScore": 1.4,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "OTHER",
            "availabilityImpact": "None",
            "baseScore": 4.0,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-024408",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-36795",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-024408",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-10687",
            "trust": 0.6,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10687"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024408"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-36795"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Insecure permissions in Netgear WNR614 JNR1010V2/N300-V1.1.0.54_1.0.1 allows attackers to access URLs and directories embedded within the firmware via unspecified vectors. of netgear WNR614 A path traversal vulnerability exists in firmware.Information may be tampered with. NETGEAR WNR614 is an N300 wireless router with an external antenna from NETGEAR Inc. Attackers can exploit this vulnerability to cause information leakage",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-36795"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024408"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-10687"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-36795",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024408",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-10687",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10687"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024408"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-36795"
      }
    ]
  },
  "id": "VAR-202406-2615",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10687"
      }
    ],
    "trust": 1.15
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10687"
      }
    ]
  },
  "last_update_date": "2025-06-01T23:09:27.961000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-22",
        "trust": 1.0
      },
      {
        "problemtype": "Path traversal (CWE-22) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024408"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-36795"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://redfoxsec.com/blog/security-advisory-multiple-vulnerabilities-in-netgear-wnr614-router/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-36795"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10687"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024408"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-36795"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-10687"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024408"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-36795"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-10687"
      },
      {
        "date": "2025-05-30T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-024408"
      },
      {
        "date": "2024-06-06T21:15:48.687000",
        "db": "NVD",
        "id": "CVE-2024-36795"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-27T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-10687"
      },
      {
        "date": "2025-05-30T02:39:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-024408"
      },
      {
        "date": "2025-05-29T16:14:02.487000",
        "db": "NVD",
        "id": "CVE-2024-36795"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "of netgear \u00a0WNR614\u00a0 Path traversal vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024408"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…