VAR-202403-0986

Vulnerability from variot - Updated: 2025-07-30 22:59

A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258159. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of fh1203 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda FH1203 is a dual-band wireless router released by China's Tenda Group, primarily used for home network coverage. This vulnerability stems from the failure of the cmdinput parameter in the formexeCommand method of the /goform/execCommand file to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202403-0986",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fh1203",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "tenda",
        "version": "2.0.1.6"
      },
      {
        "model": "fh1203",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "fh1203",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "fh1203  firmware  2.0.1.6"
      },
      {
        "model": "fh1203",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-016584"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2990"
      }
    ]
  },
  "cve": "CVE-2024-2990",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CVE-2024-2990",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "OTHER",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-016584",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2025-17051",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2024-2990",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-016584",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-2990",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-2990",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-016584",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-17051",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-016584"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2990"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2990"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258159. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of fh1203 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda FH1203 is a dual-band wireless router released by China\u0027s Tenda Group, primarily used for home network coverage. This vulnerability stems from the failure of the cmdinput parameter in the formexeCommand method of the /goform/execCommand file to properly validate the length of input data. An attacker could exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-2990"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-016584"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-2990",
        "trust": 3.2
      },
      {
        "db": "VULDB",
        "id": "258159",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-016584",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-17051",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-016584"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2990"
      }
    ]
  },
  "id": "VAR-202403-0986",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      }
    ]
  },
  "last_update_date": "2025-07-30T22:59:52.883000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda FH1203 formexeCommand method buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/713231"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-016584"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2990"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/fh/fh1203/formexecommand.md"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?id.258159"
      },
      {
        "trust": 1.8,
        "url": "https://vuldb.com/?submit.301365"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.258159"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-2990"
      },
      {
        "trust": 0.6,
        "url": "https://patchstack.com/database/vulnerability/travelers-map/wordpress-travelers-map-plugin-2-2-0-cross-site-scripting-xss-vulnerability?_s_id=cve"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-016584"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2990"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-016584"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-2990"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-07-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      },
      {
        "date": "2025-01-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-016584"
      },
      {
        "date": "2024-03-27T19:15:49.710000",
        "db": "NVD",
        "id": "CVE-2024-2990"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-07-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-17051"
      },
      {
        "date": "2025-01-16T05:42:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-016584"
      },
      {
        "date": "2025-01-15T18:21:14.240000",
        "db": "NVD",
        "id": "CVE-2024-2990"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0fh1203\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-016584"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.