VAR-201912-1176

Vulnerability from variot - Updated: 2024-11-23 22:33

A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process. SIMATIC S7-1200 CPU family and S7-200 SMART CPU family Contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Siemens SIMATIC S7-1200 CPU family products are designed for discrete and continuous control in industrial environments such as manufacturing, food and beverage, and chemical industries.

A security hole exists in the Siemens SIMATIC S7-1200 CPU. At the time of advisory publication no public exploitation of this security vulnerability was known

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201912-1176",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "s7-1200 cpu",
        "scope": null,
        "trust": 1.2,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart cpu cr60s",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.0"
      },
      {
        "model": "simatic s7-200 smart cpu cr40",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.2.2"
      },
      {
        "model": "simatic s7-1200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "s7-200 smart",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-200 smart cpu st40",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5.0"
      },
      {
        "model": "simatic s7-200 smart cpu st60",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5.0"
      },
      {
        "model": "simatic s7-200 smart cpu cr20s",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.0"
      },
      {
        "model": "simatic s7-200 smart cpu st30",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5.0"
      },
      {
        "model": "simatic s7-200 smart cpu sr60",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5.0"
      },
      {
        "model": "simatic s7-200 smart cpu cr30s",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.0"
      },
      {
        "model": "simatic s7-200 smart cpu sr30",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5.0"
      },
      {
        "model": "simatic s7-200 smart cpu cr40s",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3.0"
      },
      {
        "model": "simatic s7-200 smart cpu sr20",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5.0"
      },
      {
        "model": "simatic s7-200 smart cpu sr40",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5.0"
      },
      {
        "model": "simatic s7-200 smart cpu st20",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5.0"
      },
      {
        "model": "simatic s7-200 smart cpu cr60",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.2.2"
      },
      {
        "model": "simatic s7-1200",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-200 smart cpu",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1200",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "s7 200 smart",
        "version": "*"
      },
      {
        "model": "s7-1200 cpu",
        "scope": "eq",
        "trust": 0.2,
        "vendor": "siemens",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19"
      },
      {
        "db": "IVD",
        "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-46387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13945"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1200_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-200_smart_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      }
    ]
  },
  "cve": "CVE-2019-13945",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-13945",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-40513",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2019-46387",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.9,
            "id": "CVE-2019-13945",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Physical",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.8,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2019-13945",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-13945",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-13945",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-40513",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-46387",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201911-652",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f",
            "trust": 0.2,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19"
      },
      {
        "db": "IVD",
        "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-46387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-652"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13945"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family \u003c V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) \u003c 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions \u003c= V2.2.2 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions \u003c= V2.2.2 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process. SIMATIC S7-1200 CPU family and S7-200 SMART CPU family Contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Siemens SIMATIC S7-1200 CPU family products are designed for discrete and continuous control in industrial environments such as manufacturing, food and beverage, and chemical industries. \n\nA security hole exists in the Siemens SIMATIC S7-1200 CPU. At the time of advisory publication no public exploitation of this security vulnerability was known",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-13945"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-46387"
      },
      {
        "db": "IVD",
        "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19"
      },
      {
        "db": "IVD",
        "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f"
      }
    ],
    "trust": 3.06
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-13945",
        "trust": 3.2
      },
      {
        "db": "SIEMENS",
        "id": "SSA-686531",
        "trust": 2.2
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-318-02",
        "trust": 1.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-46387",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-652",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013306",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.4315",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "16F26ECD-5B01-4277-9A9C-D934C8DEFB19",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "E37402A9-F6CA-43BD-9AE6-72FFB6B98C6F",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19"
      },
      {
        "db": "IVD",
        "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-46387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-652"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13945"
      }
    ]
  },
  "id": "VAR-201912-1176",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19"
      },
      {
        "db": "IVD",
        "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-46387"
      }
    ],
    "trust": 2.3221314275
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 1.0
      },
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19"
      },
      {
        "db": "IVD",
        "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-46387"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:33:38.262000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-686531",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf"
      },
      {
        "title": "Patch for Siemens SIMATIC S7-1200 CPU Access Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/189929"
      },
      {
        "title": "Siemens SIMATIC S7-200  and S7-1200 Enter the fix for the verification error vulnerability",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=124059"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-652"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-749",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-20",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13945"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-13945"
      },
      {
        "trust": 1.2,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-318-02"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-13945"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-318-02"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/siemens-simatic-s7-1200-privilege-escalation-via-diagnostic-functionality-30832"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2019.4315/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-46387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-652"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13945"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19"
      },
      {
        "db": "IVD",
        "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-46387"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-652"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-13945"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-12-20T00:00:00",
        "db": "IVD",
        "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19"
      },
      {
        "date": "2019-11-14T00:00:00",
        "db": "IVD",
        "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f"
      },
      {
        "date": "2019-11-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "date": "2019-12-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-46387"
      },
      {
        "date": "2019-12-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      },
      {
        "date": "2019-11-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201911-652"
      },
      {
        "date": "2019-12-12T14:15:15.133000",
        "db": "NVD",
        "id": "CVE-2019-13945"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-11-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      },
      {
        "date": "2019-12-20T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-46387"
      },
      {
        "date": "2019-12-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-013306"
      },
      {
        "date": "2020-10-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201911-652"
      },
      {
        "date": "2024-11-21T04:25:44.930000",
        "db": "NVD",
        "id": "CVE-2019-13945"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SIMATIC S7-1200 CPU Access vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-40513"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "IVD",
        "id": "16f26ecd-5b01-4277-9a9c-d934c8defb19"
      },
      {
        "db": "IVD",
        "id": "e37402a9-f6ca-43bd-9ae6-72ffb6b98c6f"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201911-652"
      }
    ],
    "trust": 1.0
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.