VAR-201801-0158

Vulnerability from variot - Updated: 2024-11-23 22:48

A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. Rockwell Automation Allen-Bradley MicroLogix 1400 The controller contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Due to the nature of this issue, code execution may be possible but this has not been confirmed

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201801-0158",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "1766-l32bxba",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32bwaa",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32bwa",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32awaa",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32awa",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32bxb",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32awa",
        "scope": null,
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": null
      },
      {
        "model": "1766-l32awaa",
        "scope": null,
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": null
      },
      {
        "model": "1766-l32bwa",
        "scope": null,
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": null
      },
      {
        "model": "1766-l32bwaa",
        "scope": null,
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": null
      },
      {
        "model": "1766-l32bxb",
        "scope": null,
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": null
      },
      {
        "model": "1766-l32bxba",
        "scope": null,
        "trust": 0.8,
        "vendor": "rockwell automation",
        "version": null
      },
      {
        "model": "automation micrologix 1766-l32bxba",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwell",
        "version": "1400\u003c=21.002"
      },
      {
        "model": "automation micrologix 1766-l32bxb",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwell",
        "version": "1400\u003c=21.002"
      },
      {
        "model": "automation micrologix 1766-l32bwaa",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwell",
        "version": "1400\u003c=21.002"
      },
      {
        "model": "automation micrologix 1766-l32bwa",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwell",
        "version": "1400\u003c=21.002"
      },
      {
        "model": "automation micrologix 1766-l32awaa",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwell",
        "version": "1400\u003c=21.002"
      },
      {
        "model": "automation micrologix 1766-l32awa",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwell",
        "version": "1400\u003c=21.002"
      },
      {
        "model": "1766-l32bwa",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32bxba",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32awaa",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32awa",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32bwaa",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "1766-l32bxb",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwellautomation",
        "version": "21.002"
      },
      {
        "model": "automation micrologix 1766-l32bxba",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.002"
      },
      {
        "model": "automation micrologix 1766-l32bxb",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.002"
      },
      {
        "model": "automation micrologix 1766-l32bwaa",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.002"
      },
      {
        "model": "automation micrologix 1766-l32bwa",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.002"
      },
      {
        "model": "automation micrologix 1766-l32awaa",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.002"
      },
      {
        "model": "automation micrologix 1766-l32awa",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.002"
      },
      {
        "model": "automation micrologix 1766-l32bxba",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.003"
      },
      {
        "model": "automation micrologix 1766-l32bxb",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.003"
      },
      {
        "model": "automation micrologix 1766-l32bwaa",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.003"
      },
      {
        "model": "automation micrologix 1766-l32bwa",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.003"
      },
      {
        "model": "automation micrologix 1766-l32awaa",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.003"
      },
      {
        "model": "automation micrologix 1766-l32awa",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "rockwell",
        "version": "140021.003"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "1766 l32bxba",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "1766 l32awa",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "1766 l32bxb",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "1766 l32bwaa",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "1766 l32awaa",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "1766 l32bwa",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      },
      {
        "db": "BID",
        "id": "102474"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201801-329"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16740"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/h:rockwellautomation:1766-l32awa",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:rockwellautomation:1766-l32awaa",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:rockwellautomation:1766-l32bwa",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:rockwellautomation:1766-l32bwaa",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:rockwellautomation:1766-l32bxb",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:rockwellautomation:1766-l32bxba",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Thiago Alves of the University of Alabama.",
    "sources": [
      {
        "db": "BID",
        "id": "102474"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2017-16740",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2017-16740",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-00883",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-107693",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 10.0,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2017-16740",
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2017-16740",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2017-16740",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-00883",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201801-329",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-107693",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2017-16740",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107693"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-16740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201801-329"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16740"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution. Rockwell Automation Allen-Bradley MicroLogix 1400 The controller contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Due to the nature of this issue, code execution may be possible but this has not been confirmed",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2017-16740"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      },
      {
        "db": "BID",
        "id": "102474"
      },
      {
        "db": "IVD",
        "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107693"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-16740"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2017-16740",
        "trust": 3.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-009-01",
        "trust": 3.5
      },
      {
        "db": "BID",
        "id": "102474",
        "trust": 2.1
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201801-329",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-00883",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022",
        "trust": 0.8
      },
      {
        "db": "NSFOCUS",
        "id": "38658",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "E2E17CCF-39AB-11E9-8B0C-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-99028",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-107693",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-16740",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107693"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-16740"
      },
      {
        "db": "BID",
        "id": "102474"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201801-329"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16740"
      }
    ]
  },
  "id": "VAR-201801-0158",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107693"
      }
    ],
    "trust": 1.5481481833333333
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:48:52.080000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "MicroLogix 1400\u30b3\u30f3\u30c8\u30ed\u30fc\u30e9",
        "trust": 0.8,
        "url": "http://ab.rockwellautomation.com/ja/Programmable-Controllers/MicroLogix-1400"
      },
      {
        "title": "Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers Series B and C Buffer Overflow Vulnerability Patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/113399"
      },
      {
        "title": "Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers Series B  and C Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=77602"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201801-329"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-107693"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16740"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.5,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-009-01"
      },
      {
        "trust": 1.8,
        "url": "http://www.securityfocus.com/bid/102474"
      },
      {
        "trust": 1.2,
        "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1070883"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-16740"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-16740"
      },
      {
        "trust": 0.7,
        "url": "https://tools.cisco.com/security/center/viewalert.x?alertid=56434"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/38658"
      },
      {
        "trust": 0.3,
        "url": "http://www.rockwellautomation.com/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/119.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107693"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-16740"
      },
      {
        "db": "BID",
        "id": "102474"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201801-329"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16740"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      },
      {
        "db": "VULHUB",
        "id": "VHN-107693"
      },
      {
        "db": "VULMON",
        "id": "CVE-2017-16740"
      },
      {
        "db": "BID",
        "id": "102474"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201801-329"
      },
      {
        "db": "NVD",
        "id": "CVE-2017-16740"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-01-15T00:00:00",
        "db": "IVD",
        "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1"
      },
      {
        "date": "2018-01-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      },
      {
        "date": "2018-01-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107693"
      },
      {
        "date": "2018-01-09T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-16740"
      },
      {
        "date": "2018-01-09T00:00:00",
        "db": "BID",
        "id": "102474"
      },
      {
        "date": "2018-02-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      },
      {
        "date": "2018-01-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201801-329"
      },
      {
        "date": "2018-01-09T21:29:00.420000",
        "db": "NVD",
        "id": "CVE-2017-16740"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-01-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-00883"
      },
      {
        "date": "2018-08-16T00:00:00",
        "db": "VULHUB",
        "id": "VHN-107693"
      },
      {
        "date": "2018-08-16T00:00:00",
        "db": "VULMON",
        "id": "CVE-2017-16740"
      },
      {
        "date": "2018-01-09T00:00:00",
        "db": "BID",
        "id": "102474"
      },
      {
        "date": "2018-02-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      },
      {
        "date": "2018-01-10T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201801-329"
      },
      {
        "date": "2024-11-21T03:16:52.917000",
        "db": "NVD",
        "id": "CVE-2017-16740"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201801-329"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Rockwell Automation Allen-Bradley MicroLogix 1400 Buffer error vulnerability in the controller",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2017-012022"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer overflow",
    "sources": [
      {
        "db": "IVD",
        "id": "e2e17ccf-39ab-11e9-8b0c-000c29342cb1"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201801-329"
      }
    ],
    "trust": 0.8
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.