A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
n/a Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers Affected: Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T20:35:21.014Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "102474",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102474"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1070883"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-009-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers"
            }
          ]
        }
      ],
      "datePublic": "2018-01-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-16T19:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "102474",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102474"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1070883"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-009-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-16740",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "102474",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102474"
            },
            {
              "name": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1070883",
              "refsource": "CONFIRM",
              "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1070883"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-009-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-009-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-16740",
    "datePublished": "2018-01-09T21:00:00",
    "dateReserved": "2017-11-09T00:00:00",
    "dateUpdated": "2024-08-05T20:35:21.014Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-16740\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2018-01-09T21:29:00.420\",\"lastModified\":\"2024-11-21T03:16:52.917\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and earlier. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution.\"},{\"lang\":\"es\",\"value\":\"Se ha descubierto un problema de desbordamiento de b\u00fafer en Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B y C, en versiones 21.002 y anteriores. Se ha identificado una vulnerabilidad de desbordamiento de b\u00fafer basado en pila, lo que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":true,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1766-l32bxba_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21.002\",\"matchCriteriaId\":\"7E9D1B7A-C310-4E73-884C-F0730294CF01\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1766-l32bxba:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F03C6CFA-F770-4BCA-BB74-BD0D43C250F7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1766-l32awa_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21.002\",\"matchCriteriaId\":\"8FC1BA3D-024D-490D-AFC0-6C5B624AD759\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1766-l32awa:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5EC2A03F-A665-4874-896C-B603110BADA0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1766-l32bxb_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21.002\",\"matchCriteriaId\":\"9B390FC5-BE0C-43B1-BCF3-07A3E98E910D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1766-l32bxb:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D3BFF3BE-77D5-4D28-831A-13136D8E0B6D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1766-l32bwaa_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21.002\",\"matchCriteriaId\":\"25407193-4A83-40BD-988A-17A58864D57A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1766-l32bwaa:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3250570F-0A69-4484-BD7F-012AC8A2DC7F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1766-l32awaa_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21.002\",\"matchCriteriaId\":\"F0C08079-98A4-409D-BBF4-6C47304B3955\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1766-l32awaa:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"55E42B9C-4D13-48DE-A522-28B1FA1B943E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1766-l32bwa_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21.002\",\"matchCriteriaId\":\"3D02BB40-75B6-4AD1-9FA4-1659028BBFE8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1766-l32bwa:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF023FAE-BC4D-4DB7-830E-0A522C8E51CC\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/102474\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-009-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1070883\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://www.securityfocus.com/bid/102474\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-009-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1070883\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…