SSA-333468
Vulnerability from csaf_siemens - Published: 2024-10-23 00:00 - Updated: 2024-10-23 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
InterMesh 7177 Hybrid 2.0 Subscriber
Siemens / InterMesh 7177 Hybrid 2.0 Subscriber
|
vers:all/<V8.2.12 |
Vendor Fix
Workaround
|
|
|
InterMesh 7707 Fire Subscriber
Siemens / InterMesh 7707 Fire Subscriber
|
vers:all/<V7.2.12 |
Mitigation
Vendor Fix
Workaround
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "InterMesh Subscriber devices contain multiple vulnerabilities that could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-333468: Multiple Vulnerabilities in InterMesh Subscriber Devices - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-333468.html"
},
{
"category": "self",
"summary": "SSA-333468: Multiple Vulnerabilities in InterMesh Subscriber Devices - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-333468.json"
}
],
"title": "SSA-333468: Multiple Vulnerabilities in InterMesh Subscriber Devices",
"tracking": {
"current_release_date": "2024-10-23T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-333468",
"initial_release_date": "2024-10-23T00:00:00Z",
"revision_history": [
{
"date": "2024-10-23T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV8.2.12",
"product": {
"name": "InterMesh 7177 Hybrid 2.0 Subscriber",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "InterMesh 7177 Hybrid 2.0 Subscriber"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV7.2.12",
"product": {
"name": "InterMesh 7707 Fire Subscriber",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "InterMesh 7707 Fire Subscriber"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-47901",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Disable the IP interface",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V7.2.12 or later version",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.2.12 or later version",
"product_ids": [
"1"
]
},
{
"category": "workaround",
"details": "Restrict access to the InterMesh network to trusted systems and persons only",
"product_ids": [
"1",
"2"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2024-47901"
},
{
"cve": "CVE-2024-47902",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Disable the IP interface",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V7.2.12 or later version",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.2.12 or later version",
"product_ids": [
"1"
]
},
{
"category": "workaround",
"details": "Restrict access to the InterMesh network to trusted systems and persons only",
"product_ids": [
"1",
"2"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2024-47902"
},
{
"cve": "CVE-2024-47903",
"cwe": {
"id": "CWE-250",
"name": "Execution with Unnecessary Privileges"
},
"notes": [
{
"category": "summary",
"text": "The web server of affected devices allows to write arbitrary files to the web server\u0027s DocumentRoot directory.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Disable the IP interface",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V7.2.12 or later version",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.2.12 or later version",
"product_ids": [
"1"
]
},
{
"category": "workaround",
"details": "Restrict access to the InterMesh network to trusted systems and persons only",
"product_ids": [
"1",
"2"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2024-47903"
},
{
"cve": "CVE-2024-47904",
"cwe": {
"id": "CWE-266",
"name": "Incorrect Privilege Assignment"
},
"notes": [
{
"category": "summary",
"text": "The affected devices contain a SUID binary that could allow an authenticated local attacker to execute arbitrary commands with root privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Disable the IP interface",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V7.2.12 or later version",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.2.12 or later version",
"product_ids": [
"1"
]
},
{
"category": "workaround",
"details": "Restrict access to the InterMesh network to trusted systems and persons only",
"product_ids": [
"1",
"2"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2024-47904"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.