SEVD-2024-163-01
Vulnerability from csaf_se - Published: 2024-06-11 00:00 - Updated: 2026-04-14 07:00CWE-552: Files or Directories Accessible to External Parties vulnerability exists which may prevent user to update the device firmware and prevent proper behavior of the webserver when specific files or directories are removed from the filesystem.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Modbus/TCP Ethernet Modicon M340 module Version SV3.60
Schneider Electric / Modbus/TCP Ethernet Modicon M340 module
|
BMXNOE0100
|
SV3.60 | |
|
Modbus/TCP Ethernet Modicon M340 FactoryCast module Version SV6.80
Schneider Electric / Modbus/TCP Ethernet Modicon M340 FactoryCast module
|
BMXNOE0110
|
SV6.80 | |
| Unresolved product id: 9 | — |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: 8 | — |
Vendor Fix
fix
Mitigation
fix
|
|
|
Modbus/TCP Ethernet Modicon M340 module Versions prior to SV3.60
Schneider Electric / Modbus/TCP Ethernet Modicon M340 module
|
BMXNOE0100
|
<SV3.60 |
Vendor Fix
fix
Mitigation
fix
|
|
Modbus/TCP Ethernet Modicon M340 FactoryCast module Versions prior to SV6.80
Schneider Electric / Modbus/TCP Ethernet Modicon M340 FactoryCast module
|
BMXNOE0110
|
<SV6.80 |
Vendor Fix
fix
Mitigation
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its Modicon M340 and BMXNOE0100 and \nBMXNOE0110 products. \nThe Modicon M340 is a programmable automation controller; BMXNOE0100 and \nBMXNOE0110 are network modules used with Modicon M340. \nFailure to apply the mitigations provided below may prevent user to update the device firmware \nand prevent proper behavior of the webserver. The BMXNOE and Modicon M340 operations\nare not impacted by this vulnerability.\nAugust Update: Remediations are available for BMXNOE0100 (Modbus/TCP Ethernet Modicon \nM340 module) and BMXNOE0110 (Modbus/TCP Ethernet Modicon M340 FactoryCast module)",
"title": "Overview"
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch. "
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 (CVSS v4.0). CVSS v3.1 will be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer\u2019s environment."
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Modicon M340 and BMXNOE0100 and BMXNOE0110 - SEVD-2024-163-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-01.pdf"
},
{
"category": "self",
"summary": "Modicon M340 and BMXNOE0100 and BMXNOE0110 - SEVD-2024-163-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2024-163-01.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Modicon M340, Modbus/TCP Ethernet Modicon M340 module, and Modbus/TCP Ethernet Modicon M340 FactoryCast module",
"tracking": {
"current_release_date": "2026-04-14T07:00:00.000Z",
"generator": {
"date": "2026-04-09T08:15:58.340Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2024-163-01",
"initial_release_date": "2024-06-11T00:00:00.000Z",
"revision_history": [
{
"date": "2024-06-11T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2025-08-12T04:00:00.000Z",
"number": "2.0.0",
"summary": "Remediations are available for BMXNOE0100\n(Modbus/TCP Ethernet Modicon M340 module) \nand BMXNOE0110 (Modbus/TCP Ethernet \nModicon M340 FactoryCast module)"
},
{
"date": "2026-04-14T07:00:00.000Z",
"number": "3.0.0",
"summary": "Remediation is available for Modicon M340"
}
],
"status": "final",
"version": "3.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:generic/\u003cSV3.70",
"product": {
"name": "Modicon M340 Firmware Version prior to SV3.70",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Modicon M340"
},
{
"branches": [
{
"category": "product_version",
"name": "SV3.70",
"product": {
"name": "Modicon M340 Firmware Version SV3.70",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Modicon M340"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV3.60",
"product": {
"name": "Modbus/TCP Ethernet Modicon M340 module Versions prior to SV3.60",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"BMXNOE0100"
]
}
}
}
],
"category": "product_name",
"name": "Modbus/TCP Ethernet Modicon M340 module"
},
{
"branches": [
{
"category": "product_version",
"name": "SV3.60",
"product": {
"name": "Modbus/TCP Ethernet Modicon M340 module Version SV3.60",
"product_id": "4",
"product_identification_helper": {
"model_numbers": [
"BMXNOE0100"
]
}
}
}
],
"category": "product_name",
"name": "Modbus/TCP Ethernet Modicon M340 module"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSV6.80",
"product": {
"name": "Modbus/TCP Ethernet Modicon M340 FactoryCast module Versions prior to SV6.80",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"BMXNOE0110"
]
}
}
}
],
"category": "product_name",
"name": "Modbus/TCP Ethernet Modicon M340 FactoryCast module"
},
{
"branches": [
{
"category": "product_version",
"name": "SV6.80",
"product": {
"name": "Modbus/TCP Ethernet Modicon M340 FactoryCast module Version SV6.80",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"BMXNOE0110"
]
}
}
}
],
"category": "product_name",
"name": "Modbus/TCP Ethernet Modicon M340 FactoryCast module"
},
{
"category": "product_name",
"name": "Modicon M340",
"product": {
"name": "Modicon M340",
"product_id": "7"
}
}
],
"category": "vendor",
"name": "Schneider Electric"
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon M340 Firmware versions prior to SV3.70 installed on Modicon Controller M340",
"product_id": "8"
},
"product_reference": "1",
"relates_to_product_reference": "7"
},
{
"category": "installed_on",
"full_product_name": {
"name": "Modicon M340 Firmware version SV3.70 installed on Modicon Controller M340",
"product_id": "9"
},
"product_reference": "6",
"relates_to_product_reference": "7"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Yanis Wang"
],
"organization": "DAS-Security"
}
],
"cve": "CVE-2024-5056",
"cwe": {
"id": "CWE-552",
"name": "Files or Directories Accessible to External Parties"
},
"notes": [
{
"category": "description",
"text": "CWE-552: Files or Directories Accessible to External Parties vulnerability exists which may \r\nprevent user to update the device firmware and prevent proper behavior of the webserver when \r\nspecific files or directories are removed from the filesystem.",
"title": "CVE Description"
},
{
"category": "details",
"text": "CVSS v4.0 Base Score 6.9 | High | [CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N](https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N)",
"title": "CVSS v4.0 Score"
}
],
"product_status": {
"fixed": [
"4",
"5",
"9"
],
"known_affected": [
"8",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version SV3.60 of BMXNOE0100 includes a fix for this vulnerability and is \navailable for download here:\nhttps://www.se.com/ww/en/product/BMXNOE0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card",
"product_ids": [
"2"
],
"url": "https://www.se.com/ww/en/product/BMXNOE0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card/"
},
{
"category": "vendor_fix",
"details": "Version SV3.70 of Modicon M340 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/1468-modicon-m340/#software-and-firmware",
"product_ids": [
"8"
],
"restart_required": {
"category": "system"
},
"url": "https://www.se.com/ww/en/product-range/1468-modicon-m340/#software-and-firmware"
},
{
"category": "vendor_fix",
"details": "Version SV6.80 of BMXNOE0110 includes a fix for this vulnerability and is \navailable for download here:\nhttps://www.se.com/ww/en/product/BMXNOE0110/ethernet-tcp-ip-network-module-modicon-m340-automation-platform-flash-memory-card-internal-ram-16-mb-1-x-rj45-10-100/",
"product_ids": [
"3"
],
"url": "https://www.se.com/ww/en/product/BMXNOE0110/ethernet-tcp-ip-network-module-modicon-m340-automation-platform-flash-memory-card-internal-ram-16-mb-1-x-rj45-10-100/"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \napply the following mitigations to reduce the risk of exploit: \n\u2022 Setup network segmentation and implement a firewall \nto block all unauthorized access to FTP port 21/TCP on \nthe devices.\n\u2022 FTP service is disabled by default. Deactivate the FTP \nservice after use when not needed.\n\u2022 Configure the Access Control List following the \nrecommendations of the user manuals:\no \u201cModicon M340 for Ethernet Communications \nModules and Processors User Manual\u201d in \nchapter \u201cMessaging Configuration Parameters\u201d: \nhttps://www.se.com/ww/en/download/document/31\n007131K01000/",
"product_ids": [
"2",
"3",
"8"
],
"url": "https://www.se.com/ww/en/download/document/31007131K01000/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
},
"products": [
"8",
"2",
"3"
]
}
],
"title": "CVE-2024-5056"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.