Legal Notice and Terms of Use: This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy).
Advisory Summary: ATN-B1 CPDLC relies on legacy clear text unauthenticated radio frequency links. Research demonstrates that these characteristics allow unauthorized message injection, denial-of-service conditions, and forced session resets. These vulnerabilities do not constitute an unsafe aircraft condition but can degrade operational safety margins by increasing workload, delaying safety-critical instructions, and reducing situational awareness.
Critical infrastructure sectors: Transportation Systems
Countries/areas deployed: Worldwide
Company headquarters location: Global
CWE-306 - Missing Authentication for Critical Function
Affected products
Product Identifier Version Remediation
Advisory Circular 90-117 Data Link Communications ATN-B1 CPDLC: vers:all/*
ATN-B1 CPDLC
vers:all/*
None Available
Mitigation
Mitigation
Mitigation
CWE-770 - Allocation of Resources Without Limits or Throttling
Affected products
Known affected 1 product, the same list as for CVE-2025-71409
CWE-770 - Allocation of Resources Without Limits or Throttling
Affected products
Known affected 1 product, the same list as for CVE-2025-71409
CWE-754 - Improper Check for Unusual or Exceptional Conditions
Affected products
Known affected 1 product, the same list as for CVE-2025-71409
CWE-754 - Improper Check for Unusual or Exceptional Conditions
Affected products
Known affected 1 product, the same list as for CVE-2025-71409

{
  "document": {
    "acknowledgments": [
      {
        "names": [
          "Martin Strohmeier"
        ],
        "organization": "Armasuisse",
        "summary": "reported these vulnerabilities to CISA"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://www.cisa.gov/news-events/news/traffic-light-protocol-tlp-definitions-and-usage"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "legal_disclaimer",
        "text": "This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy \u0026 Use policy (https://www.cisa.gov/privacy-policy).",
        "title": "Legal Notice and Terms of Use"
      },
      {
        "category": "summary",
        "text": "ATN-B1 CPDLC relies on legacy clear text unauthenticated radio frequency links. Research demonstrates that these characteristics allow unauthorized message injection, denial-of-service conditions, and forced session resets. These vulnerabilities do not constitute an unsafe aircraft condition but can degrade operational safety margins by increasing workload, delaying safety-critical instructions, and reducing situational awareness.",
        "title": "Advisory Summary"
      },
      {
        "category": "other",
        "text": "Transportation Systems",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Global",
        "title": "Company headquarters location"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "central@cisa.dhs.gov",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-26-219-01 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-219-01.json"
      },
      {
        "category": "self",
        "summary": "ICSA Advisory ICSA-26-219-01 - Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-219-01"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/topics/industrial-control-systems"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/news-events/news/targeted-cyber-intrusion-detection-and-mitigation-strategies-update-b"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/secure-our-world/teach-employees-avoid-phishing"
      },
      {
        "category": "external",
        "summary": "Recommended Practices",
        "url": "https://www.cisa.gov/news-events/news/avoiding-social-engineering-and-phishing-attacks"
      }
    ],
    "title": "CPDLC over ATN-B1 Vulnerabilities",
    "tracking": {
      "current_release_date": "2026-08-07T05:00:00.000000Z",
      "generator": {
        "date": "2026-08-05T22:59:15.799935Z",
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-26-219-01",
      "initial_release_date": "2026-08-07T05:00:00.000000Z",
      "revision_history": [
        {
          "date": "2026-08-07T05:00:00.000000Z",
          "legacy_version": "Initial",
          "number": "1",
          "summary": "Initial Publication"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Advisory Circular 90-117 Data Link Communications ATN-B1 CPDLC: vers:all/*",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "ATN-B1 CPDLC"
          }
        ],
        "category": "specification",
        "name": "Advisory Circular 90-117 Data Link Communications"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2025-71409",
      "cwe": {
        "id": "CWE-306",
        "name": "Missing Authentication for Critical Function"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Lack of authentication for Very High Frequency Data Link messages allows rogue ground stations to inject CPDLC messages leading to unexpected or misleading clearances and potential pilot confusion. This type of attack can be carried out remotely over radio frequency.",
          "title": "Vulnerability Summary"
        },
        {
          "category": "details",
          "text": "SSVCv2/E:N/A:N/2026-08-05T05:00:00.000000Z",
          "title": "SSVC"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "cwe.mitre.org",
          "url": "https://cwe.mitre.org/data/definitions/306.html"
        },
        {
          "category": "external",
          "summary": "www.cve.org",
          "url": "https://www.cve.org/CVERecord?id=CVE-2025-71409"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:L"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L"
        }
      ],
      "remediations": [
        {
          "category": "none_available",
          "details": "Currently, there is no mitigation available for CVE-2025-71409, CVE-2025-71410, CVE-2025-71411, CVE-2025-71412, CVE-2025-71413.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:L",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2025-71410",
      "cwe": {
        "id": "CWE-770",
        "name": "Allocation of Resources Without Limits or Throttling"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Unnumbered Disconnect (U DISC) and malformed Aviation Very High Frequency Link Control frames can terminate sessions and lead to a loss of CPDLC functions requiring a reversion to voice communication and increased controller workload. This type of attack can be carried out remotely over radio frequency.",
          "title": "Vulnerability Summary"
        },
        {
          "category": "details",
          "text": "SSVCv2/E:N/A:N/2026-08-05T05:00:00.000000Z",
          "title": "SSVC"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "cwe.mitre.org",
          "url": "https://cwe.mitre.org/data/definitions/770.html"
        },
        {
          "category": "external",
          "summary": "www.cve.org",
          "url": "https://www.cve.org/CVERecord?id=CVE-2025-71410"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
        }
      ],
      "remediations": [
        {
          "category": "none_available",
          "details": "Currently, there is no mitigation available for CVE-2025-71409, CVE-2025-71410, CVE-2025-71411, CVE-2025-71412, CVE-2025-71413.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2025-71411",
      "cwe": {
        "id": "CWE-770",
        "name": "Allocation of Resources Without Limits or Throttling"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Broadcast control frames can disconnect multiple aircraft simultaneously leading to delayed clearances and air traffic controller overload. This type of attack can be carried out remotely over radio frequency.",
          "title": "Vulnerability Summary"
        },
        {
          "category": "details",
          "text": "SSVCv2/E:N/A:N/2026-08-05T05:00:00.000000Z",
          "title": "SSVC"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "cwe.mitre.org",
          "url": "https://cwe.mitre.org/data/definitions/770.html"
        },
        {
          "category": "external",
          "summary": "www.cve.org",
          "url": "https://www.cve.org/CVERecord?id=CVE-2025-71411"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
        }
      ],
      "remediations": [
        {
          "category": "none_available",
          "details": "Currently, there is no mitigation available for CVE-2025-71409, CVE-2025-71410, CVE-2025-71411, CVE-2025-71412, CVE-2025-71413.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2025-71412",
      "cwe": {
        "id": "CWE-754",
        "name": "Improper Check for Unusual or Exceptional Conditions"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Injection of false emergency or status messages over CPDLC may lead to misallocation of resources, operational confusion, and improper response actions by flight crews, traffic controllers, and ground operations.  This type of attack can be carried out remotely over radio frequency.",
          "title": "Vulnerability Summary"
        },
        {
          "category": "details",
          "text": "SSVCv2/E:N/A:N/2026-08-05T05:00:00.000000Z",
          "title": "SSVC"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "cwe.mitre.org",
          "url": "https://cwe.mitre.org/data/definitions/754.html"
        },
        {
          "category": "external",
          "summary": "www.cve.org",
          "url": "https://www.cve.org/CVERecord?id=CVE-2025-71412"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:L"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L"
        }
      ],
      "remediations": [
        {
          "category": "none_available",
          "details": "Currently, there is no mitigation available for CVE-2025-71409, CVE-2025-71410, CVE-2025-71411, CVE-2025-71412, CVE-2025-71413.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:L",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ]
    },
    {
      "cve": "CVE-2025-71413",
      "cwe": {
        "id": "CWE-754",
        "name": "Improper Check for Unusual or Exceptional Conditions"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Malformed or out-of-sequence frames at the Aviation Very High Frequency Link Control X.25 layers cause repeated resets which may result in increased workload and reduced situational awareness. This type of attack can be carried out remotely over radio frequency.",
          "title": "Vulnerability Summary"
        },
        {
          "category": "details",
          "text": "SSVCv2/E:N/A:N/2026-08-05T05:00:00.000000Z",
          "title": "SSVC"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "cwe.mitre.org",
          "url": "https://cwe.mitre.org/data/definitions/754.html"
        },
        {
          "category": "external",
          "summary": "www.cve.org",
          "url": "https://www.cve.org/CVERecord?id=CVE-2025-71413"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
        }
      ],
      "remediations": [
        {
          "category": "none_available",
          "details": "Currently, there is no mitigation available for CVE-2025-71409, CVE-2025-71410, CVE-2025-71411, CVE-2025-71412, CVE-2025-71413.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "These vulnerabilities in the CPDLC protocol stack are exploitable in a lab environment. However, they require very specific conditions to be met and are unlikely to be exploited outside of a lab setting.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        },
        {
          "category": "mitigation",
          "details": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.",
          "product_ids": [
            "CSAFPID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001"
          ]
        }
      ]
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.