ICSA-23-320-14
Vulnerability from csaf_cisa - Published: 2023-11-14 00:00 - Updated: 2024-05-14 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
RUGGEDCOM APE1808
Siemens / RUGGEDCOM APE1808
|
<with_Nozomi_Guardian_/_CMC_V22.6.3_or_23.1.0 |
Mitigation
Vendor Fix
|
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Nozomi Networks has published information on vulnerabilities in \nNozomi Guardian/CMC before V22.6.3 and 23.1.0. This advisory lists the related Siemens Industrial products affected by these vulnerabilities.\nSiemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available. Customers are advised to consult and implement the workarounds provided in Nozomi Network\u0027s upstream security notifications.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-292063: Multiple Vulnerabilities in Nozomi Guardian/CMC before 22.6.3 and 23.1.0 on RUGGEDCOM APE1808 devices - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-292063.json"
},
{
"category": "self",
"summary": "SSA-292063: Multiple Vulnerabilities in Nozomi Guardian/CMC before 22.6.3 and 23.1.0 on RUGGEDCOM APE1808 devices - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-292063.html"
},
{
"category": "self",
"summary": "SSA-292063: Multiple Vulnerabilities in Nozomi Guardian/CMC before 22.6.3 and 23.1.0 on RUGGEDCOM APE1808 devices - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-292063.pdf"
},
{
"category": "self",
"summary": "SSA-292063: Multiple Vulnerabilities in Nozomi Guardian/CMC before 22.6.3 and 23.1.0 on RUGGEDCOM APE1808 devices - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-292063.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-320-14 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-320-14.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-320-14 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-14"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens RUGGEDCOM APE1808 Devices",
"tracking": {
"current_release_date": "2024-05-14T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-320-14",
"initial_release_date": "2023-11-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-11-14T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2024-05-14T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added specific product version to remediations"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cwith_Nozomi_Guardian_/_CMC_V22.6.3_or_23.1.0",
"product": {
"name": "RUGGEDCOM APE1808",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "RUGGEDCOM APE1808"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-2567",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain parameters used in the Query functionality, allows an authenticated attacker to execute arbitrary SQL queries on the DBMS used by the web application.\r\nAuthenticated users can extract arbitrary information from the DBMS in an uncontrolled way.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2023-2567: Use internal firewall features to limit access to the web management interface",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Nozomi Guardian / CMC to V23.4.1. Contact customer support to receive patch and update information.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-2567"
},
{
"cve": "CVE-2023-29245",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, may allow an unauthenticated attacker to execute arbitrary SQL statements on the DBMS used by the web application by sending specially crafted malicious network packets.\r\n\r\nMalicious users with extensive knowledge on the underlying system may be able to extract arbitrary information from the DBMS in an uncontrolled way, or to alter its structure and data.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Upgrade Nozomi Guardian / CMC to V23.4.1. Contact customer support to receive patch and update information.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-29245"
},
{
"cve": "CVE-2023-32649",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "A Denial of Service (Dos) vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields used in the Asset Intelligence functionality of our IDS, allows an unauthenticated attacker to crash the IDS module by sending specially crafted malformed network packets.\r\n\r\nDuring the (limited) time window before the IDS module is automatically restarted, network traffic may not be analyzed.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2023-32649: It is recommended to monitor the IDS log to check for abnormal stops and restarts",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Upgrade Nozomi Guardian / CMC to V23.4.1. Contact customer support to receive patch and update information.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-32649"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.