ICSA-19-295-01
Vulnerability from csaf_cisa - Published: 2019-10-22 00:00 - Updated: 2019-10-22 00:00{
"document": {
"acknowledgments": [
{
"names": [
"Haojun Hou"
],
"summary": "reporting a vulnerability to CISA"
},
{
"names": [
"Kushal Arvind Shah"
],
"organization": "Fortinet",
"summary": "reporting vulnerabilities to Schneider Electric"
},
{
"names": [
"Yongjun Liu"
],
"organization": "NSFOCUS security team",
"summary": "reporting vulnerabilities to Schneider Electric"
},
{
"organization": "Telus",
"summary": "reporting vulnerabilities to Schneider Electric"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "summary",
"text": "Haojun Hou reported a vulnerability to CISA. Kushal Arvind Shah of Fortinet,Yongjun Liu of NSFOCUS security team, and Telus reported vulnerabilities to Schneider Electric.",
"title": "Summary"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "CISAservicedesk@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-19-295-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-295-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-295-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-295-01"
}
],
"title": "ICSA-19-295-01_Schneider Electric ProClima",
"tracking": {
"current_release_date": "2019-10-22T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA USCert CSAF Generator",
"version": "1"
}
},
"id": "ICSA-19-295-01",
"initial_release_date": "2019-10-22T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-10-22T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-19-295-01 Schneider Electric ProClima"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 8.0.0",
"product": {
"name": "ProClima: all versions prior to 8.0.0",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "ProClima"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-6823",
"cwe": {
"id": "CWE-427",
"name": "Uncontrolled Search Path Element"
},
"notes": [
{
"category": "summary",
"text": "A code injection vulnerability could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system.CVE-2019-6823 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Schneider Electric has released Version 8.0.0 of ProClima and recommends users upgrade to this version or newer. ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/product-range-download/2560-proclima/#tabs-top"
},
{
"category": "mitigation",
"details": "For more information on these vulnerabilities and the associated upgrade, please see Schneider Electric\u0027s SEVD-2019-162-01",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Physical controls should be in place so no unauthorized person has access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All controllers should reside in locked cabinets and never be left in \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for devices intended.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., should be scanned before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems and ensure they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For further information related to cybersecurity in Schneider Electric\u0027s products, please visit the company\u0027s cybersecurity webpage",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page"
},
{
"category": "mitigation",
"details": "If you require additional support, Schneider Electric Industrial Cybersecurity Services team is available to help. Please visit",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/work/services/field-services/industrial-automation/industrial-cybersecurity/industrial-cybersecurity.jsp"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2019-6823"
},
{
"cve": "CVE-2019-6824",
"cwe": {
"id": "CWE-427",
"name": "Uncontrolled Search Path Element"
},
"notes": [
{
"category": "summary",
"text": "A buffer error vulnerability could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system.CVE-2019-6824 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Schneider Electric has released Version 8.0.0 of ProClima and recommends users upgrade to this version or newer. ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/product-range-download/2560-proclima/#tabs-top"
},
{
"category": "mitigation",
"details": "For more information on these vulnerabilities and the associated upgrade, please see Schneider Electric\u0027s SEVD-2019-162-01",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Physical controls should be in place so no unauthorized person has access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All controllers should reside in locked cabinets and never be left in \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for devices intended.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., should be scanned before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems and ensure they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For further information related to cybersecurity in Schneider Electric\u0027s products, please visit the company\u0027s cybersecurity webpage",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page"
},
{
"category": "mitigation",
"details": "If you require additional support, Schneider Electric Industrial Cybersecurity Services team is available to help. Please visit",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/work/services/field-services/industrial-automation/industrial-cybersecurity/industrial-cybersecurity.jsp"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2019-6824"
},
{
"cve": "CVE-2019-6825",
"cwe": {
"id": "CWE-427",
"name": "Uncontrolled Search Path Element"
},
"notes": [
{
"category": "summary",
"text": "An uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code.CVE-2019-6825 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Schneider Electric has released Version 8.0.0 of ProClima and recommends users upgrade to this version or newer. ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/product-range-download/2560-proclima/#tabs-top"
},
{
"category": "mitigation",
"details": "For more information on these vulnerabilities and the associated upgrade, please see Schneider Electric\u0027s SEVD-2019-162-01",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Physical controls should be in place so no unauthorized person has access to the ICS and safety controllers, peripheral equipment, or the ICS and safety networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All controllers should reside in locked cabinets and never be left in \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for devices intended.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., should be scanned before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems and ensure they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For further information related to cybersecurity in Schneider Electric\u0027s products, please visit the company\u0027s cybersecurity webpage",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page"
},
{
"category": "mitigation",
"details": "If you require additional support, Schneider Electric Industrial Cybersecurity Services team is available to help. Please visit",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/work/services/field-services/industrial-automation/industrial-cybersecurity/industrial-cybersecurity.jsp"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2019-6825"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.