ICSA-19-099-04
Vulnerability from csaf_cisa - Published: 2019-04-09 00:00 - Updated: 2021-03-09 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SINEMA Remote Connect Client: All versions < V2.0 HF1
Siemens / SINEMA Remote Connect Client
|
All versions < V2.0 HF1 |
Vendor Fix
Vendor Fix
Vendor Fix
fix
Mitigation
|
|
|
SINEMA Remote Connect Server: All versions < V2.0
Siemens / SINEMA Remote Connect Server
|
All versions < V2.0 |
Vendor Fix
Vendor Fix
Mitigation
|
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow an attacker to circumvent the system authorization for certain functionalities, and to execute privileged functions.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Impact of libcurl vulnerabilities to other Siemens products:\n\n- - Siemens Security Advisory SSA-936080\n\nFor more details regarding the libcurl vulnerability refer to:\n\n- - Project curl Security Advisory \"NTLM type-2 out-of-bounds buffer\n read\"\n\n- - Project curl Security Advisory \"NTLMv2 type-3 header stack buffer\n overflow\"\n\n- - Project curl Security Advisory \"SMTP end-of-response out-of-bounds\n read\"\n\nFor further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "general",
"text": "Impact of libcurl vulnerabilities to other Siemens products: - - Siemens Security Advisory SSA-936080 For more details regarding the libcurl vulnerability refer to: - - Project curl Security Advisory \"NTLM type-2 out-of-bounds buffer read\" - - Project curl Security Advisory \"NTLMv2 type-3 header stack buffer overflow\" - - Project curl Security Advisory \"SMTP end-of-response out-of-bounds read\" For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-19-099-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-099-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-099-04 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-099-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "SSA-496604: SSA-436177: Multiple Vulnerabilities in SINEMA Remote Connect - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/SSA-436177.txt"
}
],
"title": "Siemens SINEMA Remote Connect (Update A)",
"tracking": {
"current_release_date": "2021-03-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-099-04",
"initial_release_date": "2019-04-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-04-09T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-19-099-04 Siemens SINEMA Remote Connect"
},
{
"date": "2021-03-09T00:00:00.000000Z",
"legacy_version": "A",
"number": "2",
"summary": "ICSA-19-099-04 Siemens SINEMA Remote Connect (Update A)"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V2.0 HF1",
"product": {
"name": "SINEMA Remote Connect Client: All versions \u003c V2.0 HF1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SINEMA Remote Connect Client"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V2.0",
"product": {
"name": "SINEMA Remote Connect Server: All versions \u003c V2.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SINEMA Remote Connect Server"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-14618",
"cwe": {
"id": "CWE-131",
"name": "Incorrect Calculation of Buffer Size"
},
"notes": [
{
"category": "summary",
"text": "The libcurl library versions 7.15.4 to and including 7.61.0 are vulnerable to a buffer overrun. The flaw is caused by an improper calculation of the required buffer size in the Curl_ntlm_core_mk_nt_hash function of libcurl.",
"title": "Summary"
},
{
"category": "summary",
"text": "The security vulnerability could be exploited by an attacker providing a malicious HTTP server.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/de/en/view/109764829/",
"url": "https://support.industry.siemens.com/cs/de/en/view/109764829/"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-14618"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Turn off NTLM authentication to mitigate CVE-2018-16890 and\nCVE-2019-3822",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Turn off SMTP to mitigate CVE-2019-3823",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0 HF1 - Download: https://support.industry.siemens.com/cs/de/en/view/109764829/ ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/de/en/view/109764829/"
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2018-16890",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The libcurl library versions 7.34.0 to and including 7.63.0 are vulnerable to a heap buffer out-of-bounds read.",
"title": "Summary"
},
{
"category": "summary",
"text": "The security vulnerability could be exploited by an attacker providing a malicious HTTP server.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/de/en/view/109764829/",
"url": "https://support.industry.siemens.com/cs/de/en/view/109764829/"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-16890"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Turn off NTLM authentication to mitigate CVE-2018-16890 and\nCVE-2019-3822",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Turn off SMTP to mitigate CVE-2019-3823",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0 HF1 - Download: https://support.industry.siemens.com/cs/de/en/view/109764829/ ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/de/en/view/109764829/"
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2019-3822",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The libcurl library versions 7.34.0 to and including 7.63.0 are vulnerable to a stack-based buffer overflow.",
"title": "Summary"
},
{
"category": "summary",
"text": "The security vulnerability could be exploited by an attacker providing a malicious HTTP server.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/de/en/view/109764829/",
"url": "https://support.industry.siemens.com/cs/de/en/view/109764829/"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-3822"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Turn off NTLM authentication to mitigate CVE-2018-16890 and\nCVE-2019-3822",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Turn off SMTP to mitigate CVE-2019-3823",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0 HF1 - Download: https://support.industry.siemens.com/cs/de/en/view/109764829/ ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/de/en/view/109764829/"
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2019-3823",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The libcurl library versions 7.34.0 to and including 7.63.0 are vulnerable to a heap out-of-bounds read in the code handling the end-of-response for SMTP.",
"title": "Summary"
},
{
"category": "summary",
"text": "This vulnerability could allow an attacker to trigger a Denial-of-Service condition on the affected devices.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/de/en/view/109764829/",
"url": "https://support.industry.siemens.com/cs/de/en/view/109764829/"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-3823"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Turn off NTLM authentication to mitigate CVE-2018-16890 and\nCVE-2019-3822",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Turn off SMTP to mitigate CVE-2019-3823",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0 HF1 - Download: https://support.industry.siemens.com/cs/de/en/view/109764829/ ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/de/en/view/109764829/"
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2019-6570",
"cwe": {
"id": "CWE-280",
"name": "Improper Handling of Insufficient Permissions or Privileges "
},
"notes": [
{
"category": "summary",
"text": "Due to insufficient checking of user permissions, an attacker may access URLs that require special authorization.",
"title": "Summary"
},
{
"category": "summary",
"text": "An attacker must have access to a low privileged account in order to exploit the vulnerability.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/de/en/view/109764829/",
"url": "https://support.industry.siemens.com/cs/de/en/view/109764829/"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-6570"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Turn off NTLM authentication to mitigate CVE-2018-16890 and\nCVE-2019-3822",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Turn off SMTP to mitigate CVE-2019-3823",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V2.0 - Download: https://support.industry.siemens.com/cs/de/en/view/109764829/ ",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/de/en/view/109764829/"
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.