GSD-2021-27275
Vulnerability from gsd - Updated: 2023-12-13 01:23Details
This vulnerability allows remote attackers to disclose sensitive information and delete arbitrary files on affected installations of NETGEAR ProSAFE Network Management System 1.6.0.26. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the ConfigFileController class. When parsing the realName parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to disclose sensitive information or to create a denial-of-service condition on the system. Was ZDI-CAN-12125.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2021-27275",
"description": "This vulnerability allows remote attackers to disclose sensitive information and delete arbitrary files on affected installations of NETGEAR ProSAFE Network Management System 1.6.0.26. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the ConfigFileController class. When parsing the realName parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to disclose sensitive information or to create a denial-of-service condition on the system. Was ZDI-CAN-12125.",
"id": "GSD-2021-27275"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-27275"
],
"details": "This vulnerability allows remote attackers to disclose sensitive information and delete arbitrary files on affected installations of NETGEAR ProSAFE Network Management System 1.6.0.26. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the ConfigFileController class. When parsing the realName parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to disclose sensitive information or to create a denial-of-service condition on the system. Was ZDI-CAN-12125.",
"id": "GSD-2021-27275",
"modified": "2023-12-13T01:23:35.699630Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2021-27275",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ProSAFE Network Management System",
"version": {
"version_data": [
{
"version_value": "1.6.0.26"
}
]
}
}
]
},
"vendor_name": "NETGEAR"
}
]
}
},
"credit": "rgod",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to disclose sensitive information and delete arbitrary files on affected installations of NETGEAR ProSAFE Network Management System 1.6.0.26. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the ConfigFileController class. When parsing the realName parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to disclose sensitive information or to create a denial-of-service condition on the system. Was ZDI-CAN-12125."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062687/Security-Advisory-for-Denial-of-Service-on-NMS300-PSV-2020-0561",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062687/Security-Advisory-for-Denial-of-Service-on-NMS300-PSV-2020-0561"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-358/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-358/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:netgear:prosafe_network_management_system:1.6.0.26:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2021-27275"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to disclose sensitive information and delete arbitrary files on affected installations of NETGEAR ProSAFE Network Management System 1.6.0.26. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the ConfigFileController class. When parsing the realName parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to disclose sensitive information or to create a denial-of-service condition on the system. Was ZDI-CAN-12125."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062687/Security-Advisory-for-Denial-of-Service-on-NMS300-PSV-2020-0561",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062687/Security-Advisory-for-Denial-of-Service-on-NMS300-PSV-2020-0561"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-358/",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-358/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.5
}
},
"lastModifiedDate": "2021-03-30T18:45Z",
"publishedDate": "2021-03-29T21:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…