FKIE_CVE-2026-71932
Vulnerability from fkie_nvd - Published: 2026-08-24 18:17 - Updated: 2026-08-26 17:08
Severity
Summary
Multiple DrayTek VigorSwitch models contain a directory traversal vulnerability in the getSyslogFile function. The vulnerability is caused by insufficient validation of the option field. A remote attacker can trigger this vulnerability via crafted input containing path traversal sequences to access arbitrary files on the device. Exploitation requires valid administrative credentials for the device's web management interface.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2540xs",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2540xs",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch FX2120",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2282x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2282x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch Q2300x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PQ2300xb",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2542x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2542x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2542xh",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PX2060",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G1280",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P1280",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P1281x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G1282",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P1282",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2121",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2121",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PQ2121x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch Q2121x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2280x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2280x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch Q2200x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PQ2200xb",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2100",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2100",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2540x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2540x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "disclosure@vulncheck.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Multiple DrayTek VigorSwitch models contain a directory traversal vulnerability in the getSyslogFile function. The vulnerability is caused by insufficient validation of the option field. A remote attacker can trigger this vulnerability via crafted input containing path traversal sequences to access arbitrary files on the device. Exploitation requires valid administrative credentials for the device\u0027s web management interface."
}
],
"id": "CVE-2026-71932",
"lastModified": "2026-08-26T17:08:22.300",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-71932",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-24T18:45:55.167955Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-08-24T18:17:17.893",
"references": [
{
"source": "disclosure@vulncheck.com",
"url": "https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple-models-path-traversal-via-getsyslogfile"
}
],
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…