FKIE_CVE-2025-25050

Vulnerability from fkie_nvd - Published: 2025-06-13 21:15 - Updated: 2026-06-17 09:00
Summary
An out-of-bounds write vulnerability exists in the cv_upgrade_sensor_firmware functionality of Dell ControlVault3 prior to 5.15.10.14 and Dell ControlVault 3 Plus prior to 6.2.26.36. A specially crafted ControlVault API call can lead to an out-of-bounds write. An attacker can issue an API call to trigger this vulnerability.
Impacted products
Vendor Product Version

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "BCM5820X",
          "vendor": "Broadcom",
          "versions": [
            {
              "status": "affected",
              "version": "NA"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlVault3",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.15.10.14",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlVault3 Plus",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "6.2.26.36",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "source": "talos-cna@cisco.com"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An out-of-bounds write vulnerability exists in the \ncv_upgrade_sensor_firmware functionality of Dell ControlVault3 prior to 5.15.10.14 and Dell ControlVault 3 Plus prior to 6.2.26.36.\n A specially crafted ControlVault API call can lead to an out-of-bounds \nwrite. An attacker can issue an API call to trigger this vulnerability."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de escritura fuera de los l\u00edmites en la funci\u00f3n cv_upgrade_sensor_firmware de Dell ControlVault3 (versi\u00f3n anterior a la 5.15.10.14) y Dell ControlVault 3 Plus (versi\u00f3n anterior a la 6.2.26.36). Una llamada a la API de ControlVault especialmente manipulada puede provocar una escritura fuera de los l\u00edmites. Un atacante puede ejecutar una llamada a la API para activar esta vulnerabilidad."
    }
  ],
  "id": "CVE-2025-25050",
  "lastModified": "2026-06-17T09:00:12.327",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.0,
        "impactScore": 6.0,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-25050",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2025-06-17T03:55:10.750571Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2025-06-13T21:15:20.560",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "url": "https://www.dell.com/support/kbdoc/en-us/000276106/dsa-2025-053"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2137"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…