FKIE_CVE-2023-38405
Vulnerability from fkie_nvd - Published: 2023-07-17 21:15 - Updated: 2026-06-17 06:10
Severity
Summary
On Crestron 3-Series Control Systems before 1.8001.0187, crafting and sending a specific BACnet packet can cause a crash.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| crestron | cp3n_6505417_firmware | * | |
| crestron | cp3n_6505417 | - | |
| crestron | cp3_6504877_firmware | * | |
| crestron | cp3_6504877 | - | |
| crestron | cp3-gv_6506034_firmware | * | |
| crestron | cp3-gv_6506034 | - |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:crestron:3-series_control_systems:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "3-series_control_systems",
"vendor": "crestron",
"versions": [
{
"status": "affected",
"version": "1.8001.0187"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:crestron:cp3n_6505417_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "922DDE7E-A75C-487F-BE07-178B1318437C",
"versionEndExcluding": "1.8001.0187",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:crestron:cp3n_6505417:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1C6A99E6-DA1D-49FF-B424-EBFDFFD733A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:crestron:cp3_6504877_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "55FC4E45-4E7D-451D-8F3C-9DF44B023417",
"versionEndExcluding": "1.8001.0187",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:crestron:cp3_6504877:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BF09BA1F-F827-4CB0-A72C-397EBB1946E8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:crestron:cp3-gv_6506034_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EC184E2D-4CFB-4EF9-827F-DADF0E6A67AF",
"versionEndExcluding": "1.8001.0187",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:crestron:cp3-gv_6506034:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2577C4C8-37AA-4751-BC15-24CD5A3F38F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On Crestron 3-Series Control Systems before 1.8001.0187, crafting and sending a specific BACnet packet can cause a crash."
}
],
"id": "CVE-2023-38405",
"lastModified": "2026-06-17T06:10:06.213",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-38405",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-31T14:33:30.420214Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-07-17T21:15:09.907",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Release Notes"
],
"url": "https://www.crestron.com/release_notes/cp3n_1.8001.0187_release_notes.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.crestron.com/release_notes/cp3n_1.8001.0187_release_notes.pdf"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-770"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…