FKIE_CVE-2022-34819
Vulnerability from fkie_nvd - Published: 2022-07-12 10:15 - Updated: 2026-06-17 04:5010.0 (Critical) - CVSS:3.1/
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf | Patch, Vendor Advisory |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE EU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.0 \u003c V2.2.28"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.22"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.0 \u003c V2.2.28"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.0 \u003c V2.2.28"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.0 \u003c V2.2.28"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.0 \u003c V2.2.28"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1242-7 V2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET CP 1543-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0.22"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-1200 CP 1243-1 RAIL",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.46"
}
]
}
],
"source": "productcert@siemens.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "840C5C25-1E34-42FA-8221-7232622C204F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "29D4C72C-4E84-4563-9D66-5C641AB996BA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE3D7928-8E1A-400E-B790-58D6F5938E3C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93D43BC6-EDE3-4EE1-9410-4717EB641AD0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_eu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "651C66E8-B3C0-4E88-BC7C-30BF16A7F7A3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "786F3FFD-87E4-45B9-A33C-BAE58379FF39",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte_us:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF9224A6-8A35-4F4F-951F-5B24B89E5FC8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F2AA6B43-7FC7-465A-9CD8-E8A4D6DBCD27",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8_irc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12A45F37-1E7D-4748-ADAC-EC4C454B693A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1674851A-D8DC-47C5-9D63-2F1082CE0366",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BFC6ACFD-8893-4EA3-976B-FAAF7240C5DB",
"versionEndExcluding": "3.0.22",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "78127221-D455-4145-9B84-A598A284D591",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "23C55242-F638-415E-B683-EE1484770105",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07505420-ADE4-4409-AFCC-45BCBC995543",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C624BBC7-D8C5-4C2F-B56B-D59D55F013F8",
"versionStartIncluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
"matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_net_cp_1242-7_v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7FE26E32-47C0-4976-A23A-07C1AE318C35",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_net_cp_1242-7_v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "116E84DA-31F7-4AAC-A1AE-491C4C98BD49",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "43CDCCE3-B8C0-44D4-A8A0-25C49A4EA240",
"versionEndExcluding": "3.0.22",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_net_cp_1543-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5D7AB0D5-FD3E-416A-975B-D212B3350433",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E700BF4C-64B1-455C-A6A6-3E4D71FB91B7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B3C83EF-5D93-4F0B-80F9-997261F3DBA9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions \u003c V3.3.46), SIMATIC CP 1243-1 (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE EU (All versions \u003c V3.3.46), SIMATIC CP 1243-7 LTE US (All versions \u003c V3.3.46), SIMATIC CP 1243-8 IRC (All versions \u003c V3.3.46), SIMATIC CP 1542SP-1 IRC (All versions \u003e= V2.0 \u003c V2.2.28), SIMATIC CP 1543-1 (All versions \u003c V3.0.22), SIMATIC CP 1543SP-1 (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions \u003e= V2.0 \u003c V2.2.28), SIPLUS NET CP 1242-7 V2 (All versions \u003c V3.3.46), SIPLUS NET CP 1543-1 (All versions \u003c V3.0.22), SIPLUS S7-1200 CP 1243-1 (All versions \u003c V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (All versions \u003c V3.3.46). The application lacks proper validation of user-supplied data when parsing specific messages. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of device."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE EU (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1243-7 LTE US (Todas las versiones anteriores a V3. 3.46), SIMATIC CP 1243-8 IRC (Todas las versiones anteriores a V3.3.46), SIMATIC CP 1542SP-1 IRC (Todas las versiones posteriores o iguales a V2.0), SIMATIC CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIMATIC CP 1543SP-1 (Todas las versiones posteriores o iguales a V2. 0), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC (Todas las versiones posteriores o iguales a V2.0), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (Todas las versiones posteriores o iguales a V2. 0), SIPLUS NET CP 1242-7 V2 (Todas las versiones anteriores a V3.3.46), SIPLUS NET CP 1543-1 (Todas las versiones anteriores a V3.0.22), SIPLUS S7-1200 CP 1243-1 (Todas las versiones anteriores a V3.3.46), SIPLUS S7-1200 CP 1243-1 RAIL (Todas las versiones anteriores a V3.3.46). La aplicaci\u00f3n carece de una validaci\u00f3n adecuada de los datos suministrados por el usuario al analizar mensajes espec\u00edficos. Esto podr\u00eda dar lugar a un desbordamiento del b\u00fafer basado en la pila. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del dispositivo"
}
],
"id": "CVE-2022-34819",
"lastModified": "2026-06-17T04:50:58.783",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0,
"source": "nvd@nist.gov",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-34819",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:11:00.365420Z",
"version": "2.0.3"
}
}
]
},
"published": "2022-07-12T10:15:12.293",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-517377.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-122"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.