FKIE_CVE-2020-7580
Vulnerability from fkie_nvd - Published: 2020-06-10 17:15 - Updated: 2026-06-17 03:25| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf | Vendor Advisory | |
| productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04 | Third Party Advisory, US Government Resource |
{
"affected": [
{
"affectedData": [
{
"product": "SIMATIC Automation Tool",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4 SP2"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Upd3"
}
]
},
{
"product": "SIMATIC PCS neo",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0 SP1"
}
]
},
{
"product": "SIMATIC ProSave",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V17"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.8"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2 Update 4"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC STEP 7 V5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.6 SP2 HF3"
}
]
},
{
"product": "SIMATIC WinCC OA V3.16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.16 P018"
}
]
},
{
"product": "SIMATIC WinCC OA V3.17",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.17 P003"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13 SP2 Update 4"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 10"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 5"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 2"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Update 14"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 SP1 Update 3"
}
]
},
{
"product": "SINAMICS STARTER",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V5.4 HF2"
}
]
},
{
"product": "SINAMICS Startdrive",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V16 Update 3"
}
]
},
{
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0 SP2"
}
]
},
{
"product": "SINEMA Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP3"
}
]
},
{
"product": "SINUMERIK ONE virtual",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.14"
}
]
},
{
"product": "SINUMERIK Operate",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V6.14"
}
]
}
],
"source": "productcert@siemens.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_automatic_tool:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A659B687-1038-42F5-B8AC-A394E41D22A8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "744B5953-511F-42CA-80A0-DBE36A6AA144",
"versionEndExcluding": "16",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*",
"matchCriteriaId": "496E3C43-5DA8-4983-8AC6-0F32454E22F3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:update1:*:*:*:*:*:*",
"matchCriteriaId": "17BCC3CD-61D0-416D-A241-D35AF8EE5BF8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
"matchCriteriaId": "13E3BDF0-B691-4A97-A74A-A65EC910480E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_prosave:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CB7752CF-D754-4A78-999B-45FE379E03DE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
"matchCriteriaId": "658E1A3F-29D6-48D2-BCCE-0BCC41AC49F6",
"versionEndExcluding": "21.8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CAF09D6E-3375-4731-B16D-30B7592EA5FB",
"versionEndExcluding": "5.6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1A3CA33C-AFAB-418F-870F-0236B8E55943",
"versionEndIncluding": "16",
"versionStartIncluding": "13",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:-:*:*:*:*:*:*",
"matchCriteriaId": "851F8474-4568-487D-98FB-47DF7EAEAC3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp1:*:*:*:*:*:*",
"matchCriteriaId": "81EADA2F-884C-4D72-8489-71025B3EBAEE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2:*:*:*:*:*:*",
"matchCriteriaId": "78366D2F-B728-47F6-B539-5FB2D1B0419D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2_hotfix1:*:*:*:*:*:*",
"matchCriteriaId": "06A86DA0-BC1F-4306-B02E-ED2FA36BE273",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3F39B396-140B-4005-9A61-F984C9FAF742",
"versionEndExcluding": "7.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
"matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
"matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*",
"matchCriteriaId": "BF8404AB-579E-4C6B-BCA7-E95F2CE24F7D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update10:*:*:*:*:*:*",
"matchCriteriaId": "88F6B3BF-727F-432E-89D8-37FB7C76FE2B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update11:*:*:*:*:*:*",
"matchCriteriaId": "62EB588C-CBB4-4B17-9BB5-B14B1FC6BB21",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update12:*:*:*:*:*:*",
"matchCriteriaId": "AF3F613C-6707-4517-B4B8-530C912B79E6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update13:*:*:*:*:*:*",
"matchCriteriaId": "590F62CE-9245-4AC9-9FBC-35136E217B0E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update2:*:*:*:*:*:*",
"matchCriteriaId": "241D5A28-FB22-4C5B-A067-733168E847BF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update3:*:*:*:*:*:*",
"matchCriteriaId": "A5418F92-84A9-439C-B86C-ED5820697603",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update4:*:*:*:*:*:*",
"matchCriteriaId": "40631FBD-116B-4589-B77A-6C5A69990F73",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update5:*:*:*:*:*:*",
"matchCriteriaId": "64B14972-6163-4D44-A9C6-16328E02AC69",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update6:*:*:*:*:*:*",
"matchCriteriaId": "8929E926-740F-4F17-B52C-4C73914B1818",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update7:*:*:*:*:*:*",
"matchCriteriaId": "D4F72666-D10A-4EB2-80D3-18B04C101256",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update8:*:*:*:*:*:*",
"matchCriteriaId": "0E343221-1E1A-4EE7-80AE-AB24E2244BA0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update9:*:*:*:*:*:*",
"matchCriteriaId": "1BF716D7-0A77-400F-9B43-64FBE3E65735",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
"matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
"matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
"matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
"matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:*:*:*:*:*:*:*",
"matchCriteriaId": "4B9ED7EF-EF58-400F-92C9-3D52D8E39783",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.17:*:*:*:*:*:*:*",
"matchCriteriaId": "1C3F9210-7A1E-4B10-B384-119FD5733A86",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
"matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3C9253AD-BD82-4BB2-84AD-EB1892B60358",
"versionEndIncluding": "16",
"versionStartIncluding": "13",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinamics_startdrive:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C11DB09A-74E1-45EF-A162-9C1E91F54C04",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinamics_starter_commissioning_tool:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1976CDDA-F2AF-4C47-804E-2C1DF44FBF41",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinec_network_management_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "52F7076E-12F7-4F62-9804-18598C39D3FF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C55DA617-6333-40DA-AB7D-EE49A453E143",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinumerik_one_virtual:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A607E4B7-2F58-4F68-91EB-16874986E92F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinumerik_operate:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BAFC5C25-EC3C-4EB6-B5B2-478AE9CEF10F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC Automation Tool (Todas las versiones anteriores a la versi\u00f3n V4 SP2), SIMATIC NET PC Software V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versi\u00f3n V16 Upd3), SIMATIC PCS neo (Todas las versiones anteriores a la versi\u00f3n V3.0 SP1), SIMATIC ProSave (Todas las versiones anteriores a la versi\u00f3n V17), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versi\u00f3n V21. 8), SIMATIC STEP 7 (Todas las versiones anteriores a la versi\u00f3n V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (Todas las versiones anteriores a la versi\u00f3n V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a la versi\u00f3n V15. 1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC OA V3.16 (Todas las versiones anteriores a la versi\u00f3n V3.16 P018), SIMATIC WinCC OA V3. 17 (Todas las versiones anteriores a la versi\u00f3n V3.17 P003), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC Runtime Professional V13 (Todas las versiones anteriores a la versi\u00f3n V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versi\u00f3n V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC V7. 4 (Todas las versiones anteriores a la versi\u00f3n V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versi\u00f3n V7.5 SP1 Update 3), SINAMICS STARTER (Todas las versiones anteriores a la versi\u00f3n V5.4 HF2), SINAMICS Startdrive (Todas las versiones anteriores a la versi\u00f3n V16 Update 3), SINEC NMS (Todas las versiones anteriores a la versi\u00f3n V1. 0 SP2), SINEMA Server (Todas las versiones anteriores a la versi\u00f3n V14 SP3), SINUMERIK ONE virtual (Todas las versiones anteriores a la versi\u00f3n V6.14), SINUMERIK Operate (Todas las versiones anteriores a la versi\u00f3n V6.14). Un componente dentro de la aplicaci\u00f3n afectada llama regularmente a un binario de ayuda con privilegios de SISTEMA mientras la ruta de llamada no est\u00e1 citada"
}
],
"id": "CVE-2020-7580",
"lastModified": "2026-06-17T03:25:03.397",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-06-10T17:15:12.347",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-428"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-428"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.