FKIE_CVE-2020-6779
Vulnerability from fkie_nvd - Published: 2021-01-26 18:16 - Updated: 2024-11-21 05:36
Severity ?
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Summary
Use of Hard-coded Credentials in the database of Bosch FSM-2500 server and Bosch FSM-5000 server up to and including version 5.2 allows an unauthenticated remote attacker to log into the database with admin-privileges. This may result in complete compromise of the confidentiality and integrity of the stored data as well as a high availability impact on the database itself. In addition, an attacker may execute arbitrary commands on the underlying operating system.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| bosch | fsm-2500_firmware | * | |
| bosch | fsm-2500 | - | |
| bosch | fsm-5000_firmware | * | |
| bosch | fsm-5000 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:fsm-2500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DABF317D-63EF-4AC6-B5E5-58DB5598FB6E",
"versionEndIncluding": "5.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:fsm-2500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1E6F9D1B-FF23-4C52-B5E3-3727AEEBA394",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:bosch:fsm-5000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BE15D170-F377-4A15-AC5C-10974D034FFE",
"versionEndIncluding": "5.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:bosch:fsm-5000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "91E26C5C-C032-4650-8BC1-C6D78A1090F1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Use of Hard-coded Credentials in the database of Bosch FSM-2500 server and Bosch FSM-5000 server up to and including version 5.2 allows an unauthenticated remote attacker to log into the database with admin-privileges. This may result in complete compromise of the confidentiality and integrity of the stored data as well as a high availability impact on the database itself. In addition, an attacker may execute arbitrary commands on the underlying operating system."
},
{
"lang": "es",
"value": "El uso de credenciales embebidas en la base de datos del servidor Bosch FSM-2500 y el servidor Bosch FSM-5000 hasta la versi\u00f3n 5.2 incluy\u00e9ndola, permite a un atacante remoto no autenticado iniciar sesi\u00f3n en la base de datos con privilegios de administrador.\u0026#xa0;Esto puede resultar en un compromiso total de la confidencialidad e integridad de los datos almacenados, as\u00ed como un impacto de la alta disponibilidad en la propia base de datos.\u0026#xa0;Adem\u00e1s, un atacante puede ejecutar comandos arbitrarios en el sistema operativo subyacente"
}
],
"id": "CVE-2020-6779",
"lastModified": "2024-11-21T05:36:10.500",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0,
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-01-26T18:16:07.803",
"references": [
{
"source": "psirt@bosch.com",
"tags": [
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-332072-BT.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-332072-BT.html"
}
],
"sourceIdentifier": "psirt@bosch.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "psirt@bosch.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…