FKIE_CVE-2019-10938
Vulnerability from fkie_nvd - Published: 2019-08-02 14:15 - Updated: 2026-06-17 02:11| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf | Mitigation, Patch, Vendor Advisory | |
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf | Mitigation, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf | Mitigation, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf | Mitigation, Patch, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | siprotec_5_digsi_device_driver | * | |
| siemens | 6md85 | - | |
| siemens | 6md86 | - | |
| siemens | 6md89 | - | |
| siemens | 7sa82 | - | |
| siemens | 7sa86 | - | |
| siemens | 7sa87 | - | |
| siemens | 7sd82 | - | |
| siemens | 7sd86 | - | |
| siemens | 7sd87 | - | |
| siemens | 7sj82 | - | |
| siemens | 7sj85 | - | |
| siemens | 7sj86 | - | |
| siemens | 7sk82 | - | |
| siemens | 7sk85 | - | |
| siemens | 7sl82 | - | |
| siemens | 7sl86 | - | |
| siemens | 7sl87 | - | |
| siemens | 7um85 | - | |
| siemens | 7ut82 | - | |
| siemens | 7ut85 | - | |
| siemens | 7ut86 | - | |
| siemens | 7ut87 | - | |
| siemens | 7ve85 | - | |
| siemens | 7vk87 | - |
{
"affected": [
{
"affectedData": [
{
"product": "SIPROTEC 5 devices with CPU variants CP200",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.59"
}
]
},
{
"product": "SIPROTEC 5 devices with CPU variants CP300 and CP100",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.01"
}
]
},
{
"product": "Siemens Power Meters Series 9410",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.2.1"
}
]
},
{
"product": "Siemens Power Meters Series 9810",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"source": "productcert@siemens.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:siprotec_5_digsi_device_driver:*:*:*:*:*:*:*:*",
"matchCriteriaId": "302821EE-C152-47A9-95F6-9D6B82803E3C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6md85:-:*:*:*:*:*:*:*",
"matchCriteriaId": "23076116-128D-4366-B5BC-B965001FE356",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6md86:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3457758B-A04D-4544-B0FA-DF87AA11D8FE",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6md89:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1F0672FC-AEC1-445B-B958-AEDB6DCEE1E6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sa82:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AF247CA0-37E1-40DF-96F5-9F00128EA250",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sa86:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EDD3C99B-CDD8-4919-BE72-73814C2642A4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sa87:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DBE6CCA9-A246-4EB2-A57B-FE6823A9E3FD",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sd82:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E11B4A68-F533-4AC0-80A9-7374FDFE2DEA",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sd86:-:*:*:*:*:*:*:*",
"matchCriteriaId": "73F8D692-F268-45A4-9348-C67890A58881",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sd87:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3C5A3FFD-17AD-4820-97D3-2F093BD5F322",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sj82:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5739872A-E271-48BB-ABB5-17608E81AE7A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sj85:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ECC6417D-2C81-4654-B7FF-6C3E1B709962",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sj86:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C52A6630-46F3-4113-B5E8-F5BAB7801CB0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sk82:-:*:*:*:*:*:*:*",
"matchCriteriaId": "088AC7F2-4FF3-4EF9-A111-D47DB859ECA1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sk85:-:*:*:*:*:*:*:*",
"matchCriteriaId": "73DD95AC-9B8F-43CD-9483-2BB9C4E86376",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sl82:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8A9F05D9-C1DF-4D73-8634-239ABFE526DB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sl86:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0C6662F7-5E3D-43A8-9984-EF1540BC917B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7sl87:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E122323B-A42B-4DAB-A071-ACF76DC45E28",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7um85:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AAA9E810-2C00-4721-B3A6-E7CD7184BA24",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7ut82:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2E959A8E-21D1-4950-974B-A89693C14DC9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7ut85:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DA075D19-21BF-4A7C-87B8-6A9D99799826",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7ut86:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7AC0D445-9A9B-4799-8B83-8B15821A6CC1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7ut87:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D2A73860-76C5-435B-8150-1EABF644ADA0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7ve85:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2D58566D-C2F7-4D9A-ACD6-D493E4531491",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:7vk87:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5D9FD3B7-C7F7-41C1-9290-411F9D912D00",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions \u003c V7.59), SIPROTEC 5 devices with CPU variants CP300 and CP100 (All versions \u003c V8.01), Siemens Power Meters Series 9410 (All versions \u003c V2.2.1), Siemens Power Meters Series 9810 (All versions). An unauthenticated attacker with network access to the device could potentially insert arbitrary code which is executed before firmware verification in the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en los dispositivos SIPROTEC 5 con variantes de CP200 (Todas las versiones anteriores a la versi\u00f3n V7.59), dispositivos SIPROTEC 5 con variantes de CP300 y CP100 (Todas las versiones anteriores a la versi\u00f3n V8.01), Siemens Power Meters Series 9410 (Todas las versiones anteriores a la versi\u00f3n V2.2.1), Siemens Power Meters Series 9810 (Todas las versiones). Un atacante no autenticado con acceso de red al dispositivo podr\u00eda insertar un c\u00f3digo arbitrario que se ejecuta antes de la verificaci\u00f3n del firmware en el dispositivo. En el momento de la publicaci\u00f3n del aviso, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad"
}
],
"id": "CVE-2019-10938",
"lastModified": "2026-06-17T02:11:57.287",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-08-02T14:15:14.147",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.