CVE-2026-33389 (GCVE-0-2026-33389)

Vulnerability from cvelistv5 – Published: 2026-09-08 13:55 – Updated: 2026-10-15 01:18
VLAI
Title
Disabled and non-configurable certificate/host key validation in Smart Polling in Guardian/CMC before 26.3.0 and Arc before v2.7.0
Summary
An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host's identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device's data and to disrupt its operations.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-08 14:19 UTC
CWE
  • CWE-671 - Lack of Administrator Control over Security
Assigner
Nozomi CNA under the mitre root
CNA scorecard B 81/100 over 60 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Nozomi Networks Guardian Affected: 0 , < 26.3.0 (semver)
    cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*
Create a notification for this product.
Nozomi Networks CMC Affected: 0 , < 26.3.0 (semver)
    cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*
Create a notification for this product.
Nozomi Networks Arc Affected: 0 , < 2.7.0 (semver)
    cpe:2.3:a:nozomi_networks:arc:*:*:*:*:*:*:*:*
Create a notification for this product.
Siemens RUGGEDCOM APE1808 Affected: 0 , < * (custom)
guessed Create a notification for this product.
Date Public
2026-09-08 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-33389",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-08T14:19:40.637992Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-08T14:19:48.707Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "affected": [
          {
            "defaultStatus": "unknown",
            "product": "RUGGEDCOM APE1808",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-10-15T01:18:22.831Z",
          "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "shortName": "siemens-SADP"
        },
        "references": [
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-911336.html"
          }
        ],
        "x_adpType": "supplier"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Guardian",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "26.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CMC",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "26.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Arc",
          "vendor": "Nozomi Networks",
          "versions": [
            {
              "lessThan": "2.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "26.3.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "26.3.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nozomi_networks:arc:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "2.7.0",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This issue was found by Stefano Balzarotti of Nozomi Networks and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
        }
      ],
      "datePublic": "2026-09-08T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host\u0027s identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device\u0027s data and to disrupt its operations."
            }
          ],
          "value": "An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host\u0027s identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device\u0027s data and to disrupt its operations."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-94",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-94 Adversary in the Middle (AiTM)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "LOW",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:N/VA:N/SC:H/SI:L/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-671",
              "description": "CWE-671 Lack of Administrator Control over Security",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-08T13:55:16.115Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://security.nozominetworks.com/NN-2026:20-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade Guardian/CMC to v26.3.0 or later. Upgrade Arc to v2.7.0 or later.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade Guardian/CMC to v26.3.0 or later. Upgrade Arc to v2.7.0 or later."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Disabled and non-configurable certificate/host key validation in Smart Polling in Guardian/CMC before 26.3.0 and Arc before v2.7.0",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2026-33389",
    "datePublished": "2026-09-08T13:55:16.115Z",
    "dateReserved": "2026-03-19T11:28:43.172Z",
    "dateUpdated": "2026-10-15T01:18:22.831Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-33389",
      "date": "2026-11-13",
      "epss": "0.00167",
      "percentile": "0.06071"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Guardian",
                "vendor": "Nozomi Networks",
                "versions": [
                  {
                    "lessThan": "26.3.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "CMC",
                "vendor": "Nozomi Networks",
                "versions": [
                  {
                    "lessThan": "26.3.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Arc",
                "vendor": "Nozomi Networks",
                "versions": [
                  {
                    "lessThan": "2.7.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "source": "prodsec@nozominetworks.com"
          },
          {
            "affectedData": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host\u0027s identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device\u0027s data and to disrupt its operations."
          }
        ],
        "id": "CVE-2026-33389",
        "lastModified": "2026-10-15T02:19:21.373",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 1.6,
              "impactScore": 5.3,
              "source": "prodsec@nozominetworks.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:N/VA:N/SC:H/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "prodsec@nozominetworks.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-33389",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-08T14:19:40.637992Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-09-08T14:17:22.390",
        "references": [
          {
            "source": "prodsec@nozominetworks.com",
            "url": "https://security.nozominetworks.com/NN-2026:20-01"
          },
          {
            "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-911336.html"
          }
        ],
        "sourceIdentifier": "prodsec@nozominetworks.com",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-671"
              }
            ],
            "source": "prodsec@nozominetworks.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-33389",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-08T14:19:40.637992Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T14:19:44.295Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Guardian",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CMC",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "26.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Arc",
              "vendor": "Nozomi Networks",
              "versions": [
                {
                  "lessThan": "2.7.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:guardian:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.3.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:cmc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "26.3.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                },
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:nozomi_networks:arc:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "2.7.0",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This issue was found by Stefano Balzarotti of Nozomi Networks and Andrea Palanca of Nozomi Networks Product Security team during an internal investigation."
            }
          ],
          "datePublic": "2026-09-08T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host\u0027s identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device\u0027s data and to disrupt its operations."
                }
              ],
              "value": "An improper certificate/host key validation vulnerability was discovered in the Smart Polling functionality, which established encrypted connections to target devices without validating the remote host\u0027s identity, and no option was provided to enable it. A man-in-the-middle attacker positioned between a sensor and a polled device can, during a polling session, impersonate the device and intercept the communication, including the credentials used to access it. The captured credentials can then be replayed to authenticate against the device itself or against other devices sharing the same credentials, allowing the attacker to access and tamper with the device\u0027s data and to disrupt its operations."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-94",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-94 Adversary in the Middle (AiTM)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "LOW",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "LOW",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:N/VA:N/SC:H/SI:L/SA:L",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-671",
                  "description": "CWE-671 Lack of Administrator Control over Security",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-08T13:55:16.115Z",
            "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
            "shortName": "Nozomi"
          },
          "references": [
            {
              "url": "https://security.nozominetworks.com/NN-2026:20-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade Guardian/CMC to v26.3.0 or later. Upgrade Arc to v2.7.0 or later.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade Guardian/CMC to v26.3.0 or later. Upgrade Arc to v2.7.0 or later."
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Disabled and non-configurable certificate/host key validation in Smart Polling in Guardian/CMC before 26.3.0 and Arc before v2.7.0",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "assignerShortName": "Nozomi",
        "cveId": "CVE-2026-33389",
        "datePublished": "2026-09-08T13:55:16.115Z",
        "dateReserved": "2026-03-19T11:28:43.172Z",
        "dateUpdated": "2026-09-08T14:19:48.707Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.