CVE-2025-48467 (GCVE-0-2025-48467)

Vulnerability from cvelistv5 – Published: 2025-06-24 02:14 – Updated: 2025-06-25 13:21
VLAI
Title
Denial of Service via Malformed Modbus Packets
Summary
Successful exploitation of the vulnerability could allow an attacker to cause repeated reboots, potentially leading to remote denial-of-service and system unavailability.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-06-24 15:24 UTC
CWE
  • CWE-770 - Allocation of Resources Without Limits or Throttling
Impacted products
Date Public
2025-06-24 02:00
Credits
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-48467",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-24T15:24:29.015334Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-770",
                "description": "CWE-770 Allocation of Resources Without Limits or Throttling",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-25T13:21:55.559Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Advantech Wireless Sensing and Equipment (WISE)",
          "vendor": "Advantech",
          "versions": [
            {
              "status": "affected",
              "version": "A2.01 B00"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Marc Heuse"
        }
      ],
      "datePublic": "2025-06-24T02:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Successful exploitation of the vulnerability could allow an attacker to cause repeated reboots, potentially leading to remote denial-of-service and system unavailability."
            }
          ],
          "value": "Successful exploitation of the vulnerability could allow an attacker to cause repeated reboots, potentially leading to remote denial-of-service and system unavailability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-24T02:40:53.208Z",
        "orgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
        "shortName": "CSA"
      },
      "references": [
        {
          "url": "https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2025-061"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Users and administrators of affected products are advised to update to firmware version A2.02 B00 and disable Modbus TCP if it is not required in their deployment.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Users and administrators of affected products are advised to update to firmware version A2.02 B00 and disable Modbus TCP if it is not required in their deployment."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Denial of Service via Malformed Modbus Packets",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
    "assignerShortName": "CSA",
    "cveId": "CVE-2025-48467",
    "datePublished": "2025-06-24T02:14:44.681Z",
    "dateReserved": "2025-05-22T09:41:25.402Z",
    "dateUpdated": "2025-06-25T13:21:55.559Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-48467",
      "date": "2026-10-03",
      "epss": "0.00244",
      "percentile": "0.14176"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unknown",
                "product": "Advantech Wireless Sensing and Equipment (WISE)",
                "vendor": "Advantech",
                "versions": [
                  {
                    "status": "affected",
                    "version": "A2.01 B00"
                  }
                ]
              }
            ],
            "source": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:advantech:wise-4010lan_firmware:2.02b00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "329D6F6B-850F-408B-8335-820C61C1085D",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:advantech:wise-4010lan:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9241107A-6586-475F-AE13-C541F9AE8AE6",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:advantech:wise-4050lan_firmware:2.02b00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "108653D3-5184-44B1-B2BE-F8D7E8011058",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:advantech:wise-4050lan:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "72DFF800-1684-4038-BB79-C679DCAF4105",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:advantech:wise-4060lan_firmware:2.02b00:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F6FD59CB-F033-4D1B-A24C-32C361ACCD5B",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:advantech:wise-4060lan:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E7DCE031-021A-47BC-B81C-1B0DCB9EB8F1",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Successful exploitation of the vulnerability could allow an attacker to cause repeated reboots, potentially leading to remote denial-of-service and system unavailability."
          },
          {
            "lang": "es",
            "value": "La explotaci\u00f3n exitosa de esta vulnerabilidad podr\u00eda permitir a un atacante provocar reinicios repetidos, lo que podr\u00eda derivar en una denegaci\u00f3n de servicio remota y en la indisponibilidad del sistema."
          }
        ],
        "id": "CVE-2025-48467",
        "lastModified": "2026-06-17T09:29:39.973",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 3.6,
              "source": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-48467",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-24T15:24:29.015334Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2025-06-24T03:15:34.140",
        "references": [
          {
            "source": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2025-061"
          }
        ],
        "sourceIdentifier": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-770"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-06-26T03:12:29+00:00",
      "cve": "CVE-2025-48467",
      "id": "CVE-2025-48467",
      "initial_release_date": "2025-06-24T02:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Denial of Service via Malformed Modbus Packets",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-48467.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-48467",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-24T15:24:29.015334Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-770",
                    "description": "CWE-770 Allocation of Resources Without Limits or Throttling",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-24T15:24:34.381Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Advantech Wireless Sensing and Equipment (WISE)",
              "vendor": "Advantech",
              "versions": [
                {
                  "status": "affected",
                  "version": "A2.01 B00"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Marc Heuse"
            }
          ],
          "datePublic": "2025-06-24T02:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Successful exploitation of the vulnerability could allow an attacker to cause repeated reboots, potentially leading to remote denial-of-service and system unavailability."
                }
              ],
              "value": "Successful exploitation of the vulnerability could allow an attacker to cause repeated reboots, potentially leading to remote denial-of-service and system unavailability."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-24T02:40:53.208Z",
            "orgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
            "shortName": "CSA"
          },
          "references": [
            {
              "url": "https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2025-061"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users and administrators of affected products are advised to update to firmware version A2.02 B00 and disable Modbus TCP if it is not required in their deployment.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Users and administrators of affected products are advised to update to firmware version A2.02 B00 and disable Modbus TCP if it is not required in their deployment."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Denial of Service via Malformed Modbus Packets",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
        "assignerShortName": "CSA",
        "cveId": "CVE-2025-48467",
        "datePublished": "2025-06-24T02:14:44.681Z",
        "dateReserved": "2025-05-22T09:41:25.402Z",
        "dateUpdated": "2025-06-25T13:21:55.559Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…