CVE-2025-27769 (GCVE-0-2025-27769)

Vulnerability from cvelistv5 – Published: 2026-03-10 16:07 – Updated: 2026-03-10 16:41
VLAI
Summary
A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-03-10 16:33 UTC
CWE
  • CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
Assigner
siemens CNA under the icscert root
CNA scorecard C 65/100 over 100 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Siemens Heliox Flex 180 kW EV Charging Station Affected: 0 , < F4.11.1 (custom)
guessed Create a notification for this product.
Siemens Heliox Mobile DC 40 kW EV Charging Station Affected: 0 , < L4.10.1 (custom)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27769",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T16:33:20.023387Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-10T16:41:10.032Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Heliox Flex 180 kW EV Charging Station",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "F4.11.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Heliox Mobile DC 40 kW EV Charging Station",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "L4.10.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions \u003c F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions \u003c L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 2.6,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 2.4,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-923",
              "description": "CWE-923: Improper Restriction of Communication Channel to Intended Endpoints",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-10T16:07:43.641Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-126399.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-27769",
    "datePublished": "2026-03-10T16:07:43.641Z",
    "dateReserved": "2025-03-06T16:53:49.577Z",
    "dateUpdated": "2026-03-10T16:41:10.032Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-27769",
      "date": "2026-10-28",
      "epss": "0.0015",
      "percentile": "0.04116"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex 180 kW EV Charging Station",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "F4.11.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Mobile DC 40 kW EV Charging Station",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "L4.10.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "productcert@siemens.com"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions \u003c F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions \u003c L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable."
          },
          {
            "lang": "es",
            "value": "Se ha identificado una vulnerabilidad en la estaci\u00f3n de carga de veh\u00edculos el\u00e9ctricos Heliox Flex 180 kW (todas las versiones \u0026lt; F4.11.1), la estaci\u00f3n de carga de veh\u00edculos el\u00e9ctricos Heliox Mobile DC 40 kW (todas las versiones \u0026lt; L4.10.1). Los dispositivos afectados contienen un control de acceso inadecuado que podr\u00eda permitir a un atacante acceder a servicios no autorizados a trav\u00e9s del cable de carga."
          }
        ],
        "id": "CVE-2025-27769",
        "lastModified": "2026-06-17T09:04:11.843",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "NONE",
                "baseScore": 2.6,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 0.9,
              "impactScore": 1.4,
              "source": "productcert@siemens.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "PHYSICAL",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 2.4,
                "baseSeverity": "LOW",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "productcert@siemens.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-27769",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-10T16:33:20.023387Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-03-10T18:17:52.873",
        "references": [
          {
            "source": "productcert@siemens.com",
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-126399.html"
          }
        ],
        "sourceIdentifier": "productcert@siemens.com",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-923"
              }
            ],
            "source": "productcert@siemens.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T08:47:23+00:00",
      "cve": "CVE-2025-27769",
      "id": "CVE-2025-27769",
      "initial_release_date": "2025-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2025-27769",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-27769.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27769",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-10T16:33:20.023387Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-10T16:38:11.992Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Heliox Flex 180 kW EV Charging Station",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "F4.11.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Heliox Mobile DC 40 kW EV Charging Station",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "L4.10.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions \u003c F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions \u003c L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 2.6,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 2.4,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-923",
                  "description": "CWE-923: Improper Restriction of Communication Channel to Intended Endpoints",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-10T16:07:43.641Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-126399.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-27769",
        "datePublished": "2026-03-10T16:07:43.641Z",
        "dateReserved": "2025-03-06T16:53:49.577Z",
        "dateUpdated": "2026-03-10T16:41:10.032Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.