CVE-2025-15111 (GCVE-0-2025-15111)
Vulnerability from cvelistv5 – Published: 2025-12-30 22:41 – Updated: 2026-03-11 19:30 Unsupported When Assigned
VLAI
Title
Ksenia Security lares Home Automation 1.6 Default Credentials Vulnerability
Summary
Ksenia Security lares (legacy model) version 1.6 contains a default credentials vulnerability that allows unauthorized attackers to gain administrative access. Attackers can exploit the weak default administrative credentials to obtain full control of the home automation system.
Severity
9.8 (Critical)
CWE
- CWE-259 - Use of hard-coded password
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://www.zeroscience.mk/en/vulnerabilities/ZSL… | third-party-advisory |
| https://packetstorm.news/files/id/190180/ | exploit |
| https://www.kseniasecurity.com/ | product |
| https://www.vulncheck.com/advisories/ksenia-secur… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Ksenia Security S.p.A. | lares |
Affected:
1.6
Affected: 1.0.0.15 |
Date Public
2025-03-31 00:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-15111",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-02T14:24:12.604643Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-02T14:38:46.666Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5927.php"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "lares",
"vendor": "Ksenia Security S.p.A.",
"versions": [
{
"status": "affected",
"version": "1.6"
},
{
"status": "affected",
"version": "1.0.0.15"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Mencha Isajlovska of Zero Science Lab"
}
],
"datePublic": "2025-03-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cspan\u003eKsenia Security lares (legacy model)\u003c/span\u003e\u0026nbsp;version 1.6 contains a default credentials vulnerability that allows unauthorized attackers to gain administrative access. Attackers can exploit the weak default administrative credentials to obtain full control of the home automation system.\u003c/p\u003e"
}
],
"value": "Ksenia Security lares (legacy model)\u00a0version 1.6 contains a default credentials vulnerability that allows unauthorized attackers to gain administrative access. Attackers can exploit the weak default administrative credentials to obtain full control of the home automation system."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259 Use of hard-coded password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-11T19:30:33.994Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Zero Science Lab Disclosure (ZSL-2025-5927)",
"tags": [
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5927.php"
},
{
"name": "Packet Storm Security Exploit Entry",
"tags": [
"exploit"
],
"url": "https://packetstorm.news/files/id/190180/"
},
{
"name": "Ksenia Security Vendor Homepage",
"tags": [
"product"
],
"url": "https://www.kseniasecurity.com/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/ksenia-security-lares-home-automation-default-credentials-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"unsupported-when-assigned"
],
"title": "Ksenia Security lares Home Automation 1.6 Default Credentials Vulnerability",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-15111",
"datePublished": "2025-12-30T22:41:45.831Z",
"dateReserved": "2025-12-27T01:44:38.682Z",
"dateUpdated": "2026-03-11T19:30:33.994Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-15111",
"date": "2026-05-27",
"epss": "0.00034",
"percentile": "0.10415"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2025-15111\",\"sourceIdentifier\":\"disclosure@vulncheck.com\",\"published\":\"2025-12-30T23:15:49.557\",\"lastModified\":\"2026-03-11T20:16:12.513\",\"vulnStatus\":\"Modified\",\"cveTags\":[{\"sourceIdentifier\":\"disclosure@vulncheck.com\",\"tags\":[\"unsupported-when-assigned\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Ksenia Security lares (legacy model)\u00a0version 1.6 contains a default credentials vulnerability that allows unauthorized attackers to gain administrative access. Attackers can exploit the weak default administrative credentials to obtain full control of the home automation system.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":9.3,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-259\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:kseniasecurity:lares_firmware:1.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF94F084-2F13-427A-9CB5-9E3E95621C8B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:kseniasecurity:lares:4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DDE71F37-880F-4534-80FF-A2BE3D8E2AD4\"}]}]}],\"references\":[{\"url\":\"https://packetstorm.news/files/id/190180/\",\"source\":\"disclosure@vulncheck.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.kseniasecurity.com/\",\"source\":\"disclosure@vulncheck.com\",\"tags\":[\"Product\"]},{\"url\":\"https://www.vulncheck.com/advisories/ksenia-security-lares-home-automation-default-credentials-vulnerability\",\"source\":\"disclosure@vulncheck.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5927.php\",\"source\":\"disclosure@vulncheck.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5927.php\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-15111\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-01-02T14:24:12.604643Z\"}}}], \"references\": [{\"url\": \"https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5927.php\", \"tags\": [\"exploit\"]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-01-02T14:24:17.669Z\"}}], \"cna\": {\"tags\": [\"unsupported-when-assigned\"], \"title\": \"Ksenia Security lares Home Automation 1.6 Default Credentials Vulnerability\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Mencha Isajlovska of Zero Science Lab\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Ksenia Security S.p.A.\", \"product\": \"lares\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.6\"}, {\"status\": \"affected\", \"version\": \"1.0.0.15\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-03-31T00:00:00.000Z\", \"references\": [{\"url\": \"https://www.zeroscience.mk/en/vulnerabilities/ZSL-2025-5927.php\", \"name\": \"Zero Science Lab Disclosure (ZSL-2025-5927)\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://packetstorm.news/files/id/190180/\", \"name\": \"Packet Storm Security Exploit Entry\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.kseniasecurity.com/\", \"name\": \"Ksenia Security Vendor Homepage\", \"tags\": [\"product\"]}, {\"url\": \"https://www.vulncheck.com/advisories/ksenia-security-lares-home-automation-default-credentials-vulnerability\", \"tags\": [\"third-party-advisory\"]}], \"x_generator\": {\"engine\": \"vulncheck\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Ksenia Security lares (legacy model)\\u00a0version 1.6 contains a default credentials vulnerability that allows unauthorized attackers to gain administrative access. Attackers can exploit the weak default administrative credentials to obtain full control of the home automation system.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003e\u003cspan style=\\\"background-color: rgb(252, 252, 252);\\\"\u003eKsenia Security lares (legacy model)\u003c/span\u003e\u0026nbsp;version 1.6 contains a default credentials vulnerability that allows unauthorized attackers to gain administrative access. Attackers can exploit the weak default administrative credentials to obtain full control of the home automation system.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"description\": \"Use of Hard-coded Credentials\"}]}], \"providerMetadata\": {\"orgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"shortName\": \"VulnCheck\", \"dateUpdated\": \"2026-03-05T16:37:27.304Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-15111\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-03-05T16:37:27.304Z\", \"dateReserved\": \"2025-12-27T01:44:38.682Z\", \"assignerOrgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"datePublished\": \"2025-12-30T22:41:45.831Z\", \"assignerShortName\": \"VulnCheck\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…