CVE-2025-12772 (GCVE-0-2025-12772)

Vulnerability from cvelistv5 – Published: 2026-02-02 22:41 – Updated: 2026-02-04 16:53
VLAI?
Title
Plaintext Switch admin login password is seen in Brocade SANnav support save
Summary
Brocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs. When OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
Impacted products
Vendor Product Version
Brocade SANnav Affected: before 2.4.0b
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12772",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-04T15:46:39.820278Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-04T16:53:20.826Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": "before 2.4.0b"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eBrocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs.\u003c/span\u003e\u003c/p\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eWhen OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.\u003c/span\u003e\u003cspan style=\"background-color: transparent;\"\u003e\u0026nbsp;\u003c/span\u003e\u003c/p\u003e"
            }
          ],
          "value": "Brocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs.\n\nWhen OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-03T01:59:41.935Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/36846"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Plaintext Switch admin login password is seen in Brocade SANnav support save",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2025-12772",
    "datePublished": "2026-02-02T22:41:13.921Z",
    "dateReserved": "2025-11-05T20:05:22.781Z",
    "dateUpdated": "2026-02-04T16:53:20.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-12772\",\"sourceIdentifier\":\"sirt@brocade.com\",\"published\":\"2026-02-02T23:15:58.453\",\"lastModified\":\"2026-02-03T16:44:03.343\",\"vulnStatus\":\"Undergoing Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Brocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs.\\n\\nWhen OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"sirt@brocade.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"PASSIVE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"HIGH\",\"subIntegrityImpact\":\"HIGH\",\"subAvailabilityImpact\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"sirt@brocade.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"references\":[{\"url\":\"https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/36846\",\"source\":\"sirt@brocade.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-12772\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-02-04T15:46:39.820278Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-02-04T15:46:40.566Z\"}}], \"cna\": {\"title\": \"Plaintext Switch admin login password is seen in Brocade SANnav support save\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-37\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-37 Retrieve Embedded Sensitive Data\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.5, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"PASSIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Brocade\", \"product\": \"SANnav\", \"versions\": [{\"status\": \"affected\", \"version\": \"before 2.4.0b\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/36846\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.5.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Brocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs.\\n\\nWhen OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003e\u003cspan style=\\\"background-color: transparent;\\\"\u003eBrocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs.\u003c/span\u003e\u003c/p\u003e\u003cp\u003e\u003cspan style=\\\"background-color: transparent;\\\"\u003eWhen OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.\u003c/span\u003e\u003cspan style=\\\"background-color: transparent;\\\"\u003e\u0026nbsp;\u003c/span\u003e\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-312\", \"description\": \"CWE-312 Cleartext Storage of Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"87b297d7-335e-4844-9551-11b97995a791\", \"shortName\": \"brocade\", \"dateUpdated\": \"2026-02-03T01:59:41.935Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-12772\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-02-04T16:53:20.826Z\", \"dateReserved\": \"2025-11-05T20:05:22.781Z\", \"assignerOrgId\": \"87b297d7-335e-4844-9551-11b97995a791\", \"datePublished\": \"2026-02-02T22:41:13.921Z\", \"assignerShortName\": \"brocade\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…