GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-50572 (GCVE-0-2024-50572)

Vulnerability from cvelistv5 – Published: 2024-11-12 12:50 – Updated: 2025-02-11 10:28
VLAI
Summary
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-20 16:51 UTC
CWE
  • CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Impacted products
Vendor Product Version CPE status
Siemens RUGGEDCOM RM1224 LTE(4G) EU Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens RUGGEDCOM RM1224 LTE(4G) NAM Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M804PB Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M812-1 ADSL-Router Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M816-1 ADSL-Router Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M826-2 SHDSL-Router Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M874-2 Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M874-3 Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M874-3 3G-Router (CN) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M876-3 Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M876-3 (ROK) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M876-4 Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M876-4 (EU) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE M876-4 (NAM) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE MUM853-1 (A1) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE MUM853-1 (B1) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE MUM853-1 (EU) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE MUM856-1 (A1) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE MUM856-1 (B1) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE MUM856-1 (CN) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE MUM856-1 (EU) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE MUM856-1 (RoW) Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE S615 EEC LAN-Router Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE S615 LAN-Router Affected: 0 , < V8.2 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WAB762-1 Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WAM763-1 Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WAM763-1 (ME) Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WAM763-1 (US) Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WAM766-1 Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WAM766-1 (ME) Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WAM766-1 (US) Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WAM766-1 EEC Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WAM766-1 EEC (ME) Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WAM766-1 EEC (US) Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WUB762-1 Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WUB762-1 iFeatures Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WUM763-1 Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WUM763-1 (US) Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WUM766-1 Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WUM766-1 (ME) Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
Siemens SCALANCE WUM766-1 (USA) Affected: 0 , < V3.0.0 (custom)
guessed Create a notification for this product.
siemens scalance_m874-3_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_m874-3_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_m816-1_\(annex_b\)_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_m816-1_\(annex_a\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m816-1_\(annex_b\)_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_s615_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_s615_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_s615_eec_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_s615_eec_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_mum856-1_\(row\)_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_mum856-1_\(row\)_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_mum856-1_\(eu\)_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_mum856-1_\(eu\)_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_mum856-1_\(cn\)_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_mum856-1_\(cn\)_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_mum856-1_\(b1\)_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_mum856-1_\(b1\)_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_mum856-1_\(a1\)_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_mum856-1_\(a1\)_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_mum853-1_\(a1\)_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_mum853-1_\(a1\)_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_mum853-1_\(b1\)_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_mum853-1_\(b1\)_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_mum853-1_\(eu\)_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_mum853-1_\(eu\)_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_m876-4_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_m876-4_\(eu\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m876-4_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_m876-3_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_m876-3_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_m812-1_\(annex_b\)_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_m812-1_\(annex_a\)_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:scalance_m812-1_\(annex_b\)_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens scalance_m804pb_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:scalance_m804pb_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens ruggedcom_rm1224_lte\(4g\)_nam_firmware Affected: 0 , < 8.2 (custom)
    cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_eu_firmware:-:*:*:*:*:*:*:*
    cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_nam_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_m874-3_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m874-3_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_m816-1_\\(annex_a\\)_firmware:-:*:*:*:*:*:*:*",
              "cpe:2.3:o:siemens:scalance_m816-1_\\(annex_b\\)_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m816-1_\\(annex_b\\)_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_s615_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_s615_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_s615_eec_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_s615_eec_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_mum856-1_\\(row\\)_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_mum856-1_\\(row\\)_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_mum856-1_\\(eu\\)_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_mum856-1_\\(eu\\)_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_mum856-1_\\(cn\\)_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_mum856-1_\\(cn\\)_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_mum856-1_\\(b1\\)_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_mum856-1_\\(b1\\)_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_mum856-1_\\(a1\\)_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_mum856-1_\\(a1\\)_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_mum853-1_\\(a1\\)_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_mum853-1_\\(a1\\)_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_mum853-1_\\(b1\\)_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_mum853-1_\\(b1\\)_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_mum853-1_\\(eu\\)_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_mum853-1_\\(eu\\)_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_m876-4_\\(eu\\)_firmware:-:*:*:*:*:*:*:*",
              "cpe:2.3:o:siemens:scalance_m876-4_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876-4_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_m876-3_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876-3_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_m812-1_\\(annex_a\\)_firmware:-:*:*:*:*:*:*:*",
              "cpe:2.3:o:siemens:scalance_m812-1_\\(annex_b\\)_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_\\(annex_b\\)_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:scalance_m804pb_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m804pb_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_eu_firmware:-:*:*:*:*:*:*:*",
              "cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\(4g\\)_nam_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_rm1224_lte\\(4g\\)_nam_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "8.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-50572",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-20T16:51:10.879106Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-20T16:51:19.040Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) EU",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3 3G-Router (CN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (A1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (B1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM853-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (A1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (B1)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (CN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE MUM856-1 (RoW)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 EEC LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUB762-1 iFeatures",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (ME)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions \u003c V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions \u003c V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions \u003c V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions \u003c V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions \u003c V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V3.0.0). Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-11T10:28:50.351Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-354112.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-769027.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-50572",
    "datePublished": "2024-11-12T12:50:08.911Z",
    "dateReserved": "2024-10-24T13:47:50.881Z",
    "dateUpdated": "2025-02-11T10:28:50.351Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-50572",
      "date": "2026-09-17",
      "epss": "0.00672",
      "percentile": "0.50432"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-50572\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-11-12T13:15:13.503\",\"lastModified\":\"2026-06-17T08:04:43.650\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions \u003c V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions \u003c V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions \u003c V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions \u003c V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions \u003c V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V3.0.0). Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (Todas las versiones \u0026lt; V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (Todas las versiones \u0026lt; V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (Todas las versiones \u0026lt; V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (Todas las versiones \u0026lt; V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (Todas las versiones \u0026lt; V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (Todas las versiones \u0026lt; V8.2), Enrutador ADSL SCALANCE M816-1 (6GK5816-1BA00-2AA2) (Todas las versiones \u0026lt; V8.2), Enrutador SHDSL SCALANCE M826-2 (6GK5826-2AB00-2AB2) (Todas las versiones \u0026lt; V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (Todas las versiones \u0026lt; V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (Todas las versiones \u0026lt; V8.2), Enrutador 3G SCALANCE M874-3 (CN) (6GK5874-3AA00-2FA2) (Todas las versiones \u0026lt; V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (Todas las versiones \u0026lt; V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (Todas las versiones \u0026lt; V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (Todas las versiones \u0026lt; V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (Todas las versiones \u0026lt; V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (Todas las versiones \u0026lt; V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (Todas las versiones \u0026lt; V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (Todas las versiones \u0026lt; V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (Todas las versiones \u0026lt; V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (Todas las versiones \u0026lt; V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (Todas las versiones \u0026lt; V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (Todas las versiones \u0026lt; V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (Todas las versiones \u0026lt; V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (Todas las versiones \u0026lt; V8.2), SCALANCE Enrutador LAN S615 EEC (6GK5615-0AA01-2AA2) (todas las versiones anteriores a la V8.2), enrutador LAN SCALANCE S615 (6GK5615-0AA00-2AA2) (todas las versiones anteriores a la V8.2). Los dispositivos afectados no desinfectan correctamente un campo de entrada. Esto podr\u00eda permitir que un atacante remoto autenticado con privilegios administrativos inyecte c\u00f3digo o genere un shell ra\u00edz del sistema.\"}],\"affected\":[{\"source\":\"productcert@siemens.com\",\"affectedData\":[{\"vendor\":\"Siemens\",\"product\":\"RUGGEDCOM RM1224 LTE(4G) EU\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"RUGGEDCOM RM1224 LTE(4G) NAM\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M804PB\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M812-1 ADSL-Router\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M812-1 ADSL-Router\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M816-1 ADSL-Router\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M816-1 ADSL-Router\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M826-2 SHDSL-Router\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M874-2\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M874-3\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M874-3 3G-Router (CN)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M876-3\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M876-3 (ROK)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M876-4\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M876-4 (EU)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE M876-4 (NAM)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE MUM853-1 (A1)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE MUM853-1 (B1)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE MUM853-1 (EU)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE MUM856-1 (A1)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE MUM856-1 (B1)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE MUM856-1 (CN)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE MUM856-1 (EU)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE MUM856-1 (RoW)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE S615 EEC LAN-Router\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE S615 LAN-Router\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAB762-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM763-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM763-1 (ME)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM763-1 (US)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM766-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM766-1 (ME)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM766-1 (US)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM766-1 EEC\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM766-1 EEC (ME)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WAM766-1 EEC (US)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUB762-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUB762-1 iFeatures\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM763-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM763-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM763-1 (US)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM763-1 (US)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM766-1\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM766-1 (ME)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SCALANCE WUM766-1 (USA)\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V3.0.0\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"affectedData\":[{\"vendor\":\"siemens\",\"product\":\"scalance_m874-3_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_m874-3_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_m816-1_\\\\(annex_b\\\\)_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_m816-1_\\\\(annex_a\\\\)_firmware:-:*:*:*:*:*:*:*\",\"cpe:2.3:o:siemens:scalance_m816-1_\\\\(annex_b\\\\)_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_s615_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_s615_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_s615_eec_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_s615_eec_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_mum856-1_\\\\(row\\\\)_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(row\\\\)_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_mum856-1_\\\\(eu\\\\)_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(eu\\\\)_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_mum856-1_\\\\(cn\\\\)_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(cn\\\\)_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_mum856-1_\\\\(b1\\\\)_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(b1\\\\)_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_mum856-1_\\\\(a1\\\\)_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(a1\\\\)_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_mum853-1_\\\\(a1\\\\)_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_mum853-1_\\\\(a1\\\\)_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_mum853-1_\\\\(b1\\\\)_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_mum853-1_\\\\(b1\\\\)_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_mum853-1_\\\\(eu\\\\)_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_mum853-1_\\\\(eu\\\\)_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_m876-4_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_m876-4_\\\\(eu\\\\)_firmware:-:*:*:*:*:*:*:*\",\"cpe:2.3:o:siemens:scalance_m876-4_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_m876-3_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_m876-3_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_m812-1_\\\\(annex_b\\\\)_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_m812-1_\\\\(annex_a\\\\)_firmware:-:*:*:*:*:*:*:*\",\"cpe:2.3:o:siemens:scalance_m812-1_\\\\(annex_b\\\\)_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"scalance_m804pb_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:scalance_m804pb_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"siemens\",\"product\":\"ruggedcom_rm1224_lte\\\\(4g\\\\)_nam_firmware\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\\\(4g\\\\)_eu_firmware:-:*:*:*:*:*:*:*\",\"cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\\\(4g\\\\)_nam_firmware:-:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThan\":\"8.2\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2024-11-20T16:51:10.879106Z\",\"id\":\"CVE-2024-50572\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-74\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\\\(4g\\\\)_eu_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"4F7981A8-C60A-45EE-92E5-8149A3F7760F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:ruggedcom_rm1224_lte\\\\(4g\\\\)_eu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"03D8CF59-D9D4-4C50-A6E6-D6B5BDB31AEC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\\\(4g\\\\)_nam_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"6BF2D6E7-45CD-4303-B9A9-A576BC2F1B6F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:ruggedcom_rm1224_lte\\\\(4g\\\\)_nam:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"400ACE99-AF15-4C20-9A6D-F8584DA5C7CE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m804pb_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"077F8316-E68A-4787-88EF-8016D8F06F00\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C6EBA42A-93FF-4883-8626-EF78D38374D3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m812-1_\\\\(annex_a\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"780808FF-1144-4AEE-9E72-DE5B19870E2F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m812-1_\\\\(annex_a\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B680E815-D9EF-41BC-A198-85332738B1B9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m812-1_\\\\(annex_b\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"C3148BA6-091B-4203-B12E-2FFCEA1DB22D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m812-1_\\\\(annex_b\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0895418F-A4C6-40D3-8544-5AF3F5B54709\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m816-1_\\\\(annex_a\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"0BCD7E43-4CF9-4937-8A62-4B42FE03584F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m816-1_\\\\(annex_a\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7A1636E7-BF41-4BF6-8609-9675956FB947\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m816-1_\\\\(annex_b\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"A2594F8F-9DEF-4FC4-9068-B5A29C4DBA92\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m816-1_\\\\(annex_b\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"06E70F60-33E2-472F-9B25-FE19B964220B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m826-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"EDF99EF5-12B4-45EE-9BC3-59E9F744376B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m826-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"60458734-FF87-48E9-9B63-5AB9EA5ED0E5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m874-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"1DD142E4-6F7F-4751-93B6-C3508A0828DA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m874-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C933ED27-2206-4734-8EB8-6A6431D1FBF1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m874-3_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"1B7D6063-EB3D-4150-9B89-D62C38E65787\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m874-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D3258DC7-0461-4C65-8292-85C9965EA83D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m874-3_\\\\(cn\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"F8D5BDB5-AE39-472C-9A76-243DC01C97F8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m874-3_\\\\(cn\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"71B11BE1-57EB-43AB-8F7A-AFE5BA28D34A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m876-3_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"BFE41F12-80FC-46CE-BBFA-E11695C56E30\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m876-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD221BA9-3448-49E4-B3A3-D88B939785AC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m876-3_\\\\(rok\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"D5A8F79E-C849-4D3B-9103-8068DD84DAEC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m876-3_\\\\(rok\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A3FA80AA-4869-46BF-8A1B-17C54219338C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m876-4_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"FA02FE0C-5813-4994-9887-BE0AB1344FEB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m876-4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"94E4CCE9-71F7-4960-B7DE-5298EFB7C619\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m876-4_\\\\(eu\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"B43540C5-9208-42C9-BDB6-2D6C0EB665C7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m876-4_\\\\(eu\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3886E130-C39C-43D2-8B1F-F773874F8002\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_m876-4_\\\\(nam\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"EC56B2F3-EEF5-4891-92EE-917F6EA685E7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_m876-4_\\\\(nam\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CDBED616-1074-44CE-98C8-48A5387A5DAF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_mum853-1_\\\\(a1\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"BD477A4C-4C41-4068-872C-2D633E2DB5C9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_mum853-1_\\\\(a1\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DC884995-EA34-4EFA-8B3A-5C7B9BC71C32\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_mum853-1_\\\\(b1\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"01EEE560-AC67-47FE-8B30-F699CAF951FF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_mum853-1_\\\\(b1\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A94E232B-12ED-4E9D-A6D7-C66391C48F06\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_mum853-1_\\\\(eu\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"5C0D7706-40DC-4598-B24C-9BD7B20B31F4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_mum853-1_\\\\(eu\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"94AF78F7-3DF5-40FA-A496-4523183DB792\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(a1\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"6D13A44E-DE1F-4BE3-AD0B-FCF4E8DAA9E7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_mum856-1_\\\\(a1\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FF849848-87EA-41D5-8E19-871A306D332A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(b1\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"C56063A9-5A2A-4F19-AAAC-A40A01D0D69F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_mum856-1_\\\\(b1\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"77E5245F-8AA7-4132-AA7F-1FE4F86B703E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(cn\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"27486547-EDF2-45C2-84FF-7B74D75304F6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_mum856-1_\\\\(cn\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2B05B62B-1B41-4A3D-8591-57B4D0EF476F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(eu\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"124DE318-3EFE-4FDA-8306-462BB936F892\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_mum856-1_\\\\(eu\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A219D2B9-1D71-4831-BD0B-790B7057344C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(row\\\\)_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"973C1E5B-8A98-4345-8BE3-A4B7B39EEF4F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_mum856-1_\\\\(row\\\\):-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8D6FED00-E40C-458A-8D5C-9B1826DBAE24\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_s615_eec_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"7246F2E8-0A0E-4020-B806-421DB0B91C0B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_s615_eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA5D94EA-C407-446F-B98F-F647ACBBA010\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2\",\"matchCriteriaId\":\"F16CD316-4D89-45B7-83C1-138236898C0A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E917CBBB-EF41-4113-B0CA-EB91889235E7\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-354112.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-769027.html\",\"source\":\"productcert@siemens.com\"}]}}",
    "redhat_vex": {
      "current_release_date": "2025-05-28T22:19:04+00:00",
      "cve": "CVE-2024-50572",
      "id": "CVE-2024-50572",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-50572",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-50572.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-50572\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-20T16:51:10.879106Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:siemens:scalance_m874-3_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_m874-3_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_m816-1_\\\\(annex_a\\\\)_firmware:-:*:*:*:*:*:*:*\", \"cpe:2.3:o:siemens:scalance_m816-1_\\\\(annex_b\\\\)_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_m816-1_\\\\(annex_b\\\\)_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_s615_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_s615_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_s615_eec_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_s615_eec_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(row\\\\)_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_mum856-1_\\\\(row\\\\)_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(eu\\\\)_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_mum856-1_\\\\(eu\\\\)_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(cn\\\\)_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_mum856-1_\\\\(cn\\\\)_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(b1\\\\)_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_mum856-1_\\\\(b1\\\\)_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_mum856-1_\\\\(a1\\\\)_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_mum856-1_\\\\(a1\\\\)_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_mum853-1_\\\\(a1\\\\)_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_mum853-1_\\\\(a1\\\\)_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_mum853-1_\\\\(b1\\\\)_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_mum853-1_\\\\(b1\\\\)_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_mum853-1_\\\\(eu\\\\)_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_mum853-1_\\\\(eu\\\\)_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_m876-4_\\\\(eu\\\\)_firmware:-:*:*:*:*:*:*:*\", \"cpe:2.3:o:siemens:scalance_m876-4_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_m876-4_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_m876-3_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_m876-3_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_m812-1_\\\\(annex_a\\\\)_firmware:-:*:*:*:*:*:*:*\", \"cpe:2.3:o:siemens:scalance_m812-1_\\\\(annex_b\\\\)_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_m812-1_\\\\(annex_b\\\\)_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:scalance_m804pb_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"scalance_m804pb_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\\\(4g\\\\)_eu_firmware:-:*:*:*:*:*:*:*\", \"cpe:2.3:o:siemens:ruggedcom_rm1224_lte\\\\(4g\\\\)_nam_firmware:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"ruggedcom_rm1224_lte\\\\(4g\\\\)_nam_firmware\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-20T16:50:59.794Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.6, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RM1224 LTE(4G) EU\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM RM1224 LTE(4G) NAM\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M804PB\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M812-1 ADSL-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M812-1 ADSL-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M816-1 ADSL-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M816-1 ADSL-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M826-2 SHDSL-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M874-2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M874-3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M874-3 3G-Router (CN)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M876-3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M876-3 (ROK)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M876-4\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M876-4 (EU)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE M876-4 (NAM)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM853-1 (A1)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM853-1 (B1)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM853-1 (EU)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM856-1 (A1)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM856-1 (B1)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM856-1 (CN)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM856-1 (EU)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE MUM856-1 (RoW)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE S615 EEC LAN-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE S615 LAN-Router\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V8.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAB762-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM763-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM763-1 (ME)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM763-1 (US)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 (ME)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 (US)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 EEC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 EEC (ME)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WAM766-1 EEC (US)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUB762-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUB762-1 iFeatures\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM763-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM763-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM763-1 (US)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM763-1 (US)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM766-1\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM766-1 (ME)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SCALANCE WUM766-1 (USA)\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-354112.html\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-769027.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions \u003c V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions \u003c V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions \u003c V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions \u003c V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions \u003c V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions \u003c V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions \u003c V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions \u003c V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions \u003c V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions \u003c V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions \u003c V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions \u003c V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions \u003c V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions \u003c V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions \u003c V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions \u003c V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions \u003c V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions \u003c V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions \u003c V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions \u003c V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions \u003c V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions \u003c V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions \u003c V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions \u003c V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions \u003c V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions \u003c V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions \u003c V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V3.0.0). Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-74\", \"description\": \"CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2025-02-11T10:28:50.351Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-50572\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-11T10:28:50.351Z\", \"dateReserved\": \"2024-10-24T13:47:50.881Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2024-11-12T12:50:08.911Z\", \"assignerShortName\": \"siemens\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…