CVE-2024-37999 (GCVE-0-2024-37999)

Vulnerability from cvelistv5 – Published: 2024-07-08 10:29 – Updated: 2024-08-02 04:04
VLAI
Summary
A vulnerability has been identified in Medicalis Workflow Orchestrator (All versions). The affected application executes as a trusted account with high privileges and network access. This could allow an authenticated local attacker to escalate privileges.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-08 13:00 UTC
CWE
  • CWE-282 - Improper Ownership Management
Assigner
siemens CNA under the icscert root
CNA scorecard C 65/100 over 99 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Siemens Medicalis Workflow Orchestrator Affected: 0 , < * (custom)
guessed Create a notification for this product.
siemens medicalis_workflow_orchestrator Affected: 0 , ≤ * (custom)
    cpe:2.3:a:siemens:medicalis_workflow_orchestrator:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:medicalis_workflow_orchestrator:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "medicalis_workflow_orchestrator",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37999",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-08T13:00:30.371968Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-08T13:00:33.067Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T04:04:24.507Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-501799"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Medicalis Workflow Orchestrator",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Medicalis Workflow Orchestrator (All versions). The affected application executes as a trusted account with high privileges and network access. This could allow an authenticated local attacker to escalate privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-282",
              "description": "CWE-282: Improper Ownership Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-08T10:29:56.906Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-501799"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-37999",
    "datePublished": "2024-07-08T10:29:56.906Z",
    "dateReserved": "2024-06-11T12:53:52.369Z",
    "dateUpdated": "2024-08-02T04:04:24.507Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-37999",
      "date": "2026-10-15",
      "epss": "0.00139",
      "percentile": "0.02889"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unknown",
                "product": "Medicalis Workflow Orchestrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "productcert@siemens.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:medicalis_workflow_orchestrator:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "medicalis_workflow_orchestrator",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:medicalis_workflow_orchestrator:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B41D288A-8939-4C75-94C9-F199CE866B20",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability has been identified in Medicalis Workflow Orchestrator (All versions). The affected application executes as a trusted account with high privileges and network access. This could allow an authenticated local attacker to escalate privileges."
          },
          {
            "lang": "es",
            "value": "Se ha identificado una vulnerabilidad en Medicalis Workflow Orchestrator (todas las versiones). La aplicaci\u00f3n afectada se ejecuta como una cuenta confiable con altos privilegios y acceso a la red. Esto podr\u00eda permitir que un atacante local autenticado escale privilegios."
          }
        ],
        "id": "CVE-2024-37999",
        "lastModified": "2026-06-17T07:39:12.003",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "productcert@siemens.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "productcert@siemens.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-37999",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-08T13:00:30.371968Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-07-08T11:15:10.487",
        "references": [
          {
            "source": "productcert@siemens.com",
            "tags": [
              "Broken Link"
            ],
            "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-501799"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Broken Link"
            ],
            "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-501799"
          }
        ],
        "sourceIdentifier": "productcert@siemens.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-282"
              }
            ],
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-noinfo"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T21:23:33+00:00",
      "cve": "CVE-2024-37999",
      "id": "CVE-2024-37999",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-37999",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-37999.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T04:04:24.507Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-501799"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:medicalis_workflow_orchestrator:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "medicalis_workflow_orchestrator",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-37999",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-08T13:00:30.371968Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-08T13:00:26.092Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Medicalis Workflow Orchestrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Medicalis Workflow Orchestrator (All versions). The affected application executes as a trusted account with high privileges and network access. This could allow an authenticated local attacker to escalate privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-282",
                  "description": "CWE-282: Improper Ownership Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-08T10:29:56.906Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://www.siemens-healthineers.com/en-us/support-documentation/cybersecurity/shsa-501799"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-37999",
        "datePublished": "2024-07-08T10:29:56.906Z",
        "dateReserved": "2024-06-11T12:53:52.369Z",
        "dateUpdated": "2024-08-02T04:04:24.507Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.