CVE-2024-2816 (GCVE-0-2024-2816)

Vulnerability from cvelistv5 – Published: 2024-03-22 07:31 – Updated: 2024-08-21 15:06
VLAI
Title
Tenda AC15 SysToolReboot fromSysToolReboot cross-site request forgery
Summary
A vulnerability classified as problematic was found in Tenda AC15 15.03.05.18. Affected by this vulnerability is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-21 15:05 UTC
CWE
  • CWE-352 - Cross-Site Request Forgery
References
URL Tags
https://vuldb.com/?id.257671 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257671 signaturepermissions-required
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version CPE status
Tenda AC15 Affected: 15.03.05.18
guessed Create a notification for this product.
tenda ac15_firmware Affected: 15.03.05.18
    cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:41.890Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257671 | Tenda AC15 SysToolReboot fromSysToolReboot cross-site request forgery",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257671"
          },
          {
            "name": "VDB-257671 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257671"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.18"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2816",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-21T15:05:26.052141Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T15:06:37.954Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as problematic was found in Tenda AC15 15.03.05.18. Affected by this vulnerability is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC15 15.03.05.18 wurde eine problematische Schwachstelle entdeckt. Das betrifft die Funktion fromSysToolReboot der Datei /goform/SysToolReboot. Durch das Manipulieren mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352 Cross-Site Request Forgery",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-22T07:31:06.083Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257671 | Tenda AC15 SysToolReboot fromSysToolReboot cross-site request forgery",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257671"
        },
        {
          "name": "VDB-257671 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257671"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-21T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-21T22:40:21.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC15 SysToolReboot fromSysToolReboot cross-site request forgery"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2816",
    "datePublished": "2024-03-22T07:31:06.083Z",
    "dateReserved": "2024-03-21T21:35:18.285Z",
    "dateUpdated": "2024-08-21T15:06:37.954Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-2816",
      "date": "2026-10-01",
      "epss": "0.0036",
      "percentile": "0.27401"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "AC15",
                "vendor": "Tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.18"
                  }
                ]
              }
            ],
            "source": "cna@vuldb.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac15_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.18"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*",
                    "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability classified as problematic was found in Tenda AC15 15.03.05.18. Affected by this vulnerability is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad fue encontrada en Tenda AC15 15.03.05.18 y clasificada como problem\u00e1tica. La funci\u00f3n fromSysToolReboot del archivo /goform/SysToolReboot es afectada por esta vulnerabilidad. La manipulaci\u00f3n conduce a cross-site request forgery. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257671. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
          }
        ],
        "id": "CVE-2024-2816",
        "lastModified": "2026-06-17T07:25:36.597",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 1.4,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-2816",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-21T15:05:26.052141Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-03-22T08:15:10.010",
        "references": [
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required"
            ],
            "url": "https://vuldb.com/?ctiid.257671"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?id.257671"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Permissions Required"
            ],
            "url": "https://vuldb.com/?ctiid.257671"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?id.257671"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-352"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T19:25:41.890Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "VDB-257671 | Tenda AC15 SysToolReboot fromSysToolReboot cross-site request forgery",
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.257671"
              },
              {
                "name": "VDB-257671 | CTI Indicators (IOB, IOC, IOA)",
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.257671"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac15_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.18"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-2816",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-21T15:05:26.052141Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-21T15:06:29.957Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC15",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.05.18"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "yhryhryhr_tutu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability classified as problematic was found in Tenda AC15 15.03.05.18. Affected by this vulnerability is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda AC15 15.03.05.18 wurde eine problematische Schwachstelle entdeckt. Das betrifft die Funktion fromSysToolReboot der Datei /goform/SysToolReboot. Durch das Manipulieren mit unbekannten Daten kann eine cross-site request forgery-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "CWE-352 Cross-Site Request Forgery",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-22T07:31:06.083Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-257671 | Tenda AC15 SysToolReboot fromSysToolReboot cross-site request forgery",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.257671"
            },
            {
              "name": "VDB-257671 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.257671"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/fromSysToolReboot.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-03-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-03-21T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-03-21T22:40:21.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC15 SysToolReboot fromSysToolReboot cross-site request forgery"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-2816",
        "datePublished": "2024-03-22T07:31:06.083Z",
        "dateReserved": "2024-03-21T21:35:18.285Z",
        "dateUpdated": "2024-08-21T15:06:37.954Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…