CVE-2023-46143 (GCVE-0-2023-46143)
Vulnerability from cvelistv5 – Published: 2023-12-14 14:06 – Updated: 2025-05-22 17:39- CWE-494 - Download of Code Without Integrity Check
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| PHOENIX CONTACT | Automation Worx Software Suite |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | AXC 1050 |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | AXC 1050 XC |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | AXC 3050 |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | Config+ |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | FC 350 PCI ETH |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | ILC1x0 |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | ILC1x1 |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | ILC 3xx |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | PC Worx |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | PC Worx Express |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | PC WORX RT BASIC |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | PC WORX SRT |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | RFC 430 ETH-IB |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | RFC 450 ETH-IB |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | RFC 460R PN 3TX |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | RFC 470S PN 3TX |
Affected:
all
|
guessed | |
| PHOENIX CONTACT | RFC 480S PN 4TX |
Affected:
all
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.880Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-057/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-46143",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-22T17:39:21.470279Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-22T17:39:45.716Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automation Worx Software Suite",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC 1050",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC 1050 XC",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC 3050",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Config+",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FC 350 PCI ETH",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC1x0",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC1x1",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC 3xx",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC Worx",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC Worx Express",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC WORX RT BASIC",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC WORX SRT",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 430 ETH-IB",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 450 ETH-IB",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 460R PN 3TX",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 470S PN 3TX",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 480S PN 4TX",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC."
}
],
"value": "Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T14:07:36.807Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-057/"
}
],
"source": {
"advisory": "VDE-2023-057",
"defect": [
"CERT@VDE#64610"
],
"discovery": "EXTERNAL"
},
"title": "Phoenix Contact: Classic line industrial controllers prone to inadequate integrity check of PLC",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46143",
"datePublished": "2023-12-14T14:06:06.479Z",
"dateReserved": "2023-10-17T07:04:03.576Z",
"dateUpdated": "2025-05-22T17:39:45.716Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-46143",
"date": "2026-11-25",
"epss": "0.00393",
"percentile": "0.25135"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Automation Worx Software Suite",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC 1050",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC 1050 XC",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC 3050",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Config+",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FC 350 PCI ETH",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC1x0",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC1x1",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC 3xx",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC Worx",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC Worx Express",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC WORX RT BASIC",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC WORX SRT",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 430 ETH-IB",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 450 ETH-IB",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 460R PN 3TX",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 470S PN 3TX",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 480S PN 4TX",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenixcontact:automationworx_software_suite:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9797B615-825F-4CAA-B36E-5161E37FAF9A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:axc_1050_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F0D586DC-2274-4A32-AE98-7BE174C230CC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:axc_1050:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5F55C821-DAA6-4098-BB54-80F6D9ED0CD6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:axc_1050_xc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "332A6164-CDC1-4DBF-9B62-946EC7D7C4B3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:axc_1050_xc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E03B5234-36FA-4BCE-964D-F55FFFD5CAAC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:axc_3050_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "84066F7B-8306-4743-9F12-75B8F880AD93",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:axc_3050:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CB9699A2-782D-40F3-B8D6-3C315104BA60",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenixcontact:config\\+:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A6D8FDB6-6181-49EB-BE6D-236D39A478A1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:fc_350_pci_eth_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DEB7CA5B-7EEF-4E0E-9A53-83FE28730852",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:fc_350_pci_eth:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F4BB6654-41BB-488E-AC8C-E74C05CA198F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:ilc1x0_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5AC07A81-D5D6-449C-93F8-93D6E87487DD",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:ilc1x0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE45F6AF-7286-48F7-B4BE-AFC948884C7C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:ilc1x1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8E168AB1-1B81-4990-95E4-56C36275609B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:ilc1x1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9E318A8B-D1D1-4DD5-AF71-DCBFEFCF2C5E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:ilc_3xx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "65E1A201-E7B1-452B-8BC6-A355A3BF9460",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:ilc_3xx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF1C58A6-5220-4509-B426-D1ED5ECFAD05",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenixcontact:pc_worx:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B975C4E4-83B5-4C98-811B-E6D13687AB85",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenixcontact:pc_worx_express:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CE663FFA-4B82-4477-A424-4C9CC83C131E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:pc_worx_rt_basic_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8693B231-3A5C-47B7-BEA5-53D430BBACF4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:pc_worx_rt_basic:-:*:*:*:*:*:*:*",
"matchCriteriaId": "08B214FC-776F-454B-8DC4-E7F2E6EFB013",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenixcontact:pc_worx_srt:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A2A6F462-A12F-4E08-9AA6-1C1AF743A645",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:rfc_430_eth-ib_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "643E47A5-E7AA-4321-99A1-05EEBD9A2B56",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:rfc_430_eth-ib:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1F32F262-519C-41BB-BF31-ECBCAC1ABEA9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:rfc_450_eth-ib_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A91E019B-F0C5-4DF0-AE4C-E60F3D598F0C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:rfc_450_eth-ib:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C3C2EDF4-2982-4858-A960-7E7564E5B20A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:rfc_460r_pn_3tx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "302995A9-E9CC-4477-B374-CE10F16A5E10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:rfc_460r_pn_3tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F7544E2C-2E63-4C36-AB64-764B4393E377",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:rfc_470s_pn_3tx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CCAB2CA6-EEC4-4E0D-B962-FC2C4EF06013",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:rfc_470s_pn_3tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD94CBFF-CC25-4122-96FE-2308A4D1659D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:phoenixcontact:rfc_480s_pn_4tx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3B383246-EF0A-466F-89EA-F61AFC447509",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:phoenixcontact:rfc_480s_pn_4tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6B043176-58CC-438C-92D9-99F479BB1C58",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC."
},
{
"lang": "es",
"value": "La vulnerabilidad de descarga de c\u00f3digo sin verificaci\u00f3n de integridad en los PLC de la l\u00ednea cl\u00e1sica de PHOENIX CONTACT permite que un atacante remoto no autenticado modifique algunas o todas las aplicaciones en un PLC."
}
],
"id": "CVE-2023-46143",
"lastModified": "2026-06-17T06:30:14.540",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-46143",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-22T17:39:21.470279Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-12-14T14:15:43.207",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-057/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-057/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-494"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-29T00:10:34+00:00",
"cve": "CVE-2023-46143",
"id": "CVE-2023-46143",
"initial_release_date": "2023-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Phoenix Contact: Classic line industrial controllers prone to inadequate integrity check of PLC",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-46143.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.880Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-057/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-46143",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-22T17:39:21.470279Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-22T17:39:38.669Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automation Worx Software Suite",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC 1050",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC 1050 XC",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC 3050",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Config+",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FC 350 PCI ETH",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC1x0",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC1x1",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ILC 3xx",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC Worx",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC Worx Express",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC WORX RT BASIC",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC WORX SRT",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 430 ETH-IB",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 450 ETH-IB",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 460R PN 3TX",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 470S PN 3TX",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 480S PN 4TX",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC."
}
],
"value": "Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T14:07:36.807Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-057/"
}
],
"source": {
"advisory": "VDE-2023-057",
"defect": [
"CERT@VDE#64610"
],
"discovery": "EXTERNAL"
},
"title": "Phoenix Contact: Classic line industrial controllers prone to inadequate integrity check of PLC",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46143",
"datePublished": "2023-12-14T14:06:06.479Z",
"dateReserved": "2023-10-17T07:04:03.576Z",
"dateUpdated": "2025-05-22T17:39:45.716Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour