Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-42972 (GCVE-0-2022-42972)
Vulnerability from cvelistv5 – Published: 2023-02-01 00:00 – Updated: 2025-02-05 20:06- CWE-732 - Incorrect Permission Assignment for Critical Resource
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | APC Easy UPS Online Monitoring Software |
Affected:
Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GA
(custom)
|
|
| Schneider Electric | APC Easy UPS Online Monitoring Software |
Affected:
(Windows 11, Windows Server 2019, 2022 , < V2.5-GA-01-22261
(custom)
|
|
| Schneider Electric | Schneider Electric Easy UPS Online Monitoring Software |
Affected:
Windows 7, 10, 11 Windows Server 2016, 2019, 2022 , < V2.5-GS
(custom)
|
|
| Schneider Electric | Schneider Electric Easy UPS Online Monitoring Software |
Affected:
Windows 11, Windows Server 2019, 2022 , < V2.5-GS-01-22261
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:05.534Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-42972",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:52:18.807602Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:37.394Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "APC Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GA-01-22261",
"status": "affected",
"version": "(Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS",
"status": "affected",
"version": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"versionType": "custom"
}
]
},
{
"product": "Schneider Electric Easy UPS Online Monitoring Software",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "V2.5-GS-01-22261",
"status": "affected",
"version": "Windows 11, Windows Server 2019, 2022",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-01T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-42972",
"datePublished": "2023-02-01T00:00:00.000Z",
"dateReserved": "2022-10-17T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:37.394Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-42972",
"date": "2026-06-07",
"epss": "0.00038",
"percentile": "0.11608"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-42972\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-02-01T04:15:09.023\",\"lastModified\":\"2024-11-21T07:25:42.930\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.5-ga-01-22320\",\"matchCriteriaId\":\"4B8FBFEF-F5DC-4F71-B990-B74C68733741\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.5-gs-01-22320\",\"matchCriteriaId\":\"C587FB36-A05E-4925-B643-D52EE7AEF952\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.5-ga\",\"matchCriteriaId\":\"F73E8580-C9EF-4F21-A5D0-468D85BDDEE1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"E31E09C7-9F07-4FAE-8C38-16E75BC8A576\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E33796DB-4523-4F04-B564-ADF030553D51\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.5-gs\",\"matchCriteriaId\":\"D2CC95E9-44AE-4809-83DE-4AFDA682305B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"E31E09C7-9F07-4FAE-8C38-16E75BC8A576\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*\",\"matchCriteriaId\":\"647F2145-B063-43EA-8045-32D3B4D893F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E33796DB-4523-4F04-B564-ADF030553D51\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T13:19:05.534Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-42972\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-05T19:52:18.807602Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-05T19:52:20.364Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"APC Easy UPS Online Monitoring Software\", \"versions\": [{\"status\": \"affected\", \"version\": \"Windows 7, 10, 11 Windows Server 2016, 2019, 2022\", \"lessThan\": \"V2.5-GA\", \"versionType\": \"custom\"}]}, {\"vendor\": \"Schneider Electric\", \"product\": \"APC Easy UPS Online Monitoring Software\", \"versions\": [{\"status\": \"affected\", \"version\": \"(Windows 11, Windows Server 2019, 2022\", \"lessThan\": \"V2.5-GA-01-22261\", \"versionType\": \"custom\"}]}, {\"vendor\": \"Schneider Electric\", \"product\": \"Schneider Electric Easy UPS Online Monitoring Software\", \"versions\": [{\"status\": \"affected\", \"version\": \"Windows 7, 10, 11 Windows Server 2016, 2019, 2022\", \"lessThan\": \"V2.5-GS\", \"versionType\": \"custom\"}]}, {\"vendor\": \"Schneider Electric\", \"product\": \"Schneider Electric Easy UPS Online Monitoring Software\", \"versions\": [{\"status\": \"affected\", \"version\": \"Windows 11, Windows Server 2019, 2022\", \"lessThan\": \"V2.5-GS-01-22261\", \"versionType\": \"custom\"}]}], \"datePublic\": \"2022-12-13T00:00:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-732\", \"description\": \"CWE-732 Incorrect Permission Assignment for Critical Resource\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2023-02-01T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-42972\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-05T20:06:37.394Z\", \"dateReserved\": \"2022-10-17T00:00:00.000Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2023-02-01T00:00:00.000Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
{
"CVSS 2.0": "AV:L/AC:L/Au:S/C:C/I:C/A:C",
"CVSS 3.0": "AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 2.5-GA-01-22320 (APC Easy UPS Online Monitoring Software), \u0434\u043e 2.5-GS-01-22320 (Easy UPS Online)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u041a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043c\u0435\u0440\u044b:\n- \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0435\u0442\u0438 \u0441 \u0446\u0435\u043b\u044c\u044e \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u043c\u0443 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e;\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432 \u043c\u0435\u0436\u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0432\u043e\u0437\u043c\u043e\u0436\u043d\u043e\u0441\u0442\u0438 \u0443\u0434\u0430\u043b\u0451\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430.\n\n\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439: \nhttps://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "13.12.2022",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "12.04.2023",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "11.03.2023",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2023-01158",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2022-42972",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "APC Easy UPS Online Monitoring Software, Easy UPS Online",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u043d\u043b\u0430\u0439\u043d-\u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 APC Easy UPS Online Monitoring Software, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u043c \u043f\u0440\u0438\u0441\u0432\u043e\u0435\u043d\u0438\u0435\u043c \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u043e\u0433\u043e \u0440\u0435\u0441\u0443\u0440\u0441\u0430, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0435\u0435 \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043f\u043e\u0432\u044b\u0441\u0438\u0442\u044c \u0441\u0432\u043e\u0438 \u043f\u0440\u0438\u0432\u0438\u043b\u0435\u0433\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0421\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0435 \u043f\u0440\u0438\u0441\u0432\u043e\u0435\u043d\u0438\u0435 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u043e\u0433\u043e \u0440\u0435\u0441\u0443\u0440\u0441\u0430 (CWE-732)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u043d\u043b\u0430\u0439\u043d-\u043c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433\u0430 APC Easy UPS Online Monitoring Software \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u043c \u043f\u0440\u0438\u0441\u0432\u043e\u0435\u043d\u0438\u0435\u043c \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u043e\u0433\u043e \u0440\u0435\u0441\u0443\u0440\u0441\u0430. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043f\u043e\u0432\u044b\u0441\u0438\u0442\u044c \u0441\u0432\u043e\u0438 \u043f\u0440\u0438\u0432\u0438\u043b\u0435\u0433\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u043c\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf\nhttps://www.cybersecurity-help.cz/vdb/SB2022121430\nhttps://safe-surf.ru/upload/VULN/VULN-20221228.10.pdf\nhttps://vuldb.com/ru/?id.215450\nhttps://www.cisa.gov/news-events/ics-advisories/icsa-22-347-02",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u0421\u0435\u0442\u0435\u0432\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e, \u0421\u0435\u0442\u0435\u0432\u043e\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e, \u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-732",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 6,8)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)"
}
CERTFR-2022-AVI-1093
Vulnerability from certfr_avis - Published: 2022-12-13 - Updated: 2022-12-13
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | Modicon M580 CPU Safety (BMEP58*S et BMEH58*S) toutes versions | ||
| N/A | N/A | APC Easy UPS Online Monitoring versions antérieures à 2.5-GA-01-22320 | ||
| N/A | N/A | EcoStruxure Power Commission versions antérieures à 2.26 | ||
| N/A | N/A | SAITEL DR RTU Baseline 11.06.x antérieures à 1.06.15 |
| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon M580 CPU Safety (BMEP58*S et BMEH58*S) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "APC Easy UPS Online Monitoring versions ant\u00e9rieures \u00e0 2.5-GA-01-22320",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power Commission versions ant\u00e9rieures \u00e0 2.26",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "SAITEL DR RTU Baseline 11.06.x ant\u00e9rieures \u00e0 1.06.15",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-6846",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6846"
},
{
"name": "CVE-2022-42971",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42971"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2021-22791",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22791"
},
{
"name": "CVE-2022-42973",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42973"
},
{
"name": "CVE-2019-6841",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6841"
},
{
"name": "CVE-2021-22779",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22779"
},
{
"name": "CVE-2021-22790",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22790"
},
{
"name": "CVE-2022-37301",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37301"
},
{
"name": "CVE-2018-7241",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7241"
},
{
"name": "CVE-2021-22786",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22786"
},
{
"name": "CVE-2018-7242",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7242"
},
{
"name": "CVE-2019-6844",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6844"
},
{
"name": "CVE-2019-6842",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6842"
},
{
"name": "CVE-2020-6996",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-6996"
},
{
"name": "CVE-2022-37300",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37300"
},
{
"name": "CVE-2021-22789",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22789"
},
{
"name": "CVE-2019-6847",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6847"
},
{
"name": "CVE-2021-22792",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22792"
},
{
"name": "CVE-2022-42970",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42970"
},
{
"name": "CVE-2019-6843",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6843"
},
{
"name": "CVE-2018-7240",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7240"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2022-4062",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4062"
},
{
"name": "CVE-2022-42972",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42972"
}
],
"initial_release_date": "2022-12-13T00:00:00",
"last_revision_date": "2022-12-13T00:00:00",
"links": [],
"reference": "CERTFR-2022-AVI-1093",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-12-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider du 13 d\u00e9cembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01-APC_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
]
}
FKIE_CVE-2022-42972
Vulnerability from fkie_nvd - Published: 2023-02-01 04:15 - Updated: 2024-11-21 07:257.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4B8FBFEF-F5DC-4F71-B990-B74C68733741",
"versionEndExcluding": "2.5-ga-01-22320",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C587FB36-A05E-4925-B643-D52EE7AEF952",
"versionEndExcluding": "2.5-gs-01-22320",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F73E8580-C9EF-4F21-A5D0-468D85BDDEE1",
"versionEndExcluding": "2.5-ga",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*",
"matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D2CC95E9-44AE-4809-83DE-4AFDA682305B",
"versionEndExcluding": "2.5-gs",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*",
"matchCriteriaId": "E31E09C7-9F07-4FAE-8C38-16E75BC8A576",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E33796DB-4523-4F04-B564-ADF030553D51",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
],
"id": "CVE-2022-42972",
"lastModified": "2024-11-21T07:25:42.930",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-02-01T04:15:09.023",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
GHSA-GCJP-7FH4-W3CP
Vulnerability from github – Published: 2023-02-01 06:30 – Updated: 2023-02-08 21:30A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
{
"affected": [],
"aliases": [
"CVE-2022-42972"
],
"database_specific": {
"cwe_ids": [
"CWE-732"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-02-01T04:15:00Z",
"severity": "HIGH"
},
"details": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)",
"id": "GHSA-gcjp-7fh4-w3cp",
"modified": "2023-02-08T21:30:21Z",
"published": "2023-02-01T06:30:30Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-42972"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2022-42972
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-42972",
"description": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)",
"id": "GSD-2022-42972"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-42972"
],
"details": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)",
"id": "GSD-2022-42972",
"modified": "2023-12-13T01:19:10.957746Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2022-12-13T08:00:00.000Z",
"ID": "CVE-2022-42972",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "APC Easy UPS Online Monitoring Software",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"version_value": "V2.5-GA"
}
]
}
},
{
"product_name": "APC Easy UPS Online Monitoring Software",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "(Windows 11, Windows Server 2019, 2022",
"version_value": "V2.5-GA-01-22261"
}
]
}
},
{
"product_name": "Schneider Electric Easy UPS Online Monitoring Software",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022",
"version_value": "V2.5-GS"
}
]
}
},
{
"product_name": "Schneider Electric Easy UPS Online Monitoring Software",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "Windows 11, Windows Server 2019, 2022",
"version_value": "V2.5-GS-01-22261"
}
]
}
}
]
},
"vendor_name": "Schneider Electric"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-732 Incorrect Permission Assignment for Critical Resource"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.5-ga-01-22320",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.5-gs-01-22320",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.5-ga",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.5-gs",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2022-42972"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf",
"refsource": "MISC",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-02-08T19:40Z",
"publishedDate": "2023-02-01T04:15Z"
}
}
}
ICSA-22-347-02
Vulnerability from csaf_cisa - Published: 2022-12-13 00:00 - Updated: 2022-12-13 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
APC Easy UPS Online: APC Easy UPS Online Version 2.5-GA and prior (Windows 7, 10, 11, Windows Server 2016, 2019, 2022)
Schneider Electric Software, LLC / APC Easy UPS Online
|
<= 2.5-GA (Windows 7, 10, 11, Windows Server 2016, 2019, 2022) |
Mitigation
fix
|
|
|
APC Easy UPS Online: APC Easy UPS Online Version 2.5-GA-01-22261 and prior (Windows 11, Windows Server 2019, 2022)
Schneider Electric Software, LLC / APC Easy UPS Online
|
<= 2.5-GA-01-22261 (Windows 11, Windows Server 2019, 2022) |
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
APC Easy UPS Online: APC Easy UPS Online Version 2.5-GA and prior (Windows 7, 10, 11, Windows Server 2016, 2019, 2022)
Schneider Electric Software, LLC / APC Easy UPS Online
|
<= 2.5-GA (Windows 7, 10, 11, Windows Server 2016, 2019, 2022) |
Mitigation
fix
|
|
|
APC Easy UPS Online: APC Easy UPS Online Version 2.5-GA-01-22261 and prior (Windows 11, Windows Server 2019, 2022)
Schneider Electric Software, LLC / APC Easy UPS Online
|
<= 2.5-GA-01-22261 (Windows 11, Windows Server 2019, 2022) |
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
APC Easy UPS Online: APC Easy UPS Online Version 2.5-GA and prior (Windows 7, 10, 11, Windows Server 2016, 2019, 2022)
Schneider Electric Software, LLC / APC Easy UPS Online
|
<= 2.5-GA (Windows 7, 10, 11, Windows Server 2016, 2019, 2022) |
Mitigation
fix
|
|
|
APC Easy UPS Online: APC Easy UPS Online Version 2.5-GA-01-22261 and prior (Windows 11, Windows Server 2019, 2022)
Schneider Electric Software, LLC / APC Easy UPS Online
|
<= 2.5-GA-01-22261 (Windows 11, Windows Server 2019, 2022) |
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
APC Easy UPS Online: APC Easy UPS Online Version 2.5-GA and prior (Windows 7, 10, 11, Windows Server 2016, 2019, 2022)
Schneider Electric Software, LLC / APC Easy UPS Online
|
<= 2.5-GA (Windows 7, 10, 11, Windows Server 2016, 2019, 2022) |
Mitigation
fix
|
|
|
APC Easy UPS Online: APC Easy UPS Online Version 2.5-GA-01-22261 and prior (Windows 11, Windows Server 2019, 2022)
Schneider Electric Software, LLC / APC Easy UPS Online
|
<= 2.5-GA-01-22261 (Windows 11, Windows Server 2019, 2022) |
Mitigation
fix
|
{
"document": {
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro Zero Day Initiative",
"summary": "reporting CVE-2022-42970, CVE-2022-42971, and CVE-2022-42973 to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could result in unauthenticated remote code execution, unauthenticated password changes, and escalation of privileges.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": " Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": " Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": " France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-22-347-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-347-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-347-02 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-347-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
}
],
"title": "Schneider Electric APC Easy UPS Online",
"tracking": {
"current_release_date": "2022-12-13T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-347-02",
"initial_release_date": "2022-12-13T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-12-13T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 2.5-GA (Windows 7, 10, 11, Windows Server 2016, 2019, 2022)",
"product": {
"name": "APC Easy UPS Online: APC Easy UPS Online Version 2.5-GA and prior (Windows 7, 10, 11, Windows Server 2016, 2019, 2022)",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "APC Easy UPS Online"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 2.5-GA-01-22261 (Windows 11, Windows Server 2019, 2022)",
"product": {
"name": "APC Easy UPS Online: APC Easy UPS Online Version 2.5-GA-01-22261 and prior (Windows 11, Windows Server 2019, 2022)",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "APC Easy UPS Online"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-42970",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "summary",
"text": "Schneider Electric APC Easy UPS Online versions 2.5-GA and prior are missing authentication for the updatePassword endpoint implemented in the LoginAction.updatePassword method. An unauthenticated user could exploit this vulnerability to modify administrator passwords.CVE-2022-42970 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-42970"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users to update the affected product to the latest version. See Schneider Electric\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01-APC_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2022-42971",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "summary",
"text": "Schneider Electric APC Easy UPS Online versions 2.5-GA and prior deploy the improperly secured UpLoadAction.execute method. An unauthenticated user could use this method to upload a maliciously crafted JSF file to the images directory, which is located in the application web root directory, to enable unauthenticated remote code execution.CVE-2022-42971 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-42971"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users to update the affected product to the latest version. See Schneider Electric\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01-APC_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2022-42972",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "Schneider Electric APC Easy UPS Online versions 2.5-GA and prior run the Tomcat instance with SYSTEM privileges. NT AUTHORITY\\Authenticated Users could create new files in the Tomcat web root directory and could create and execute a maliciously crafted JSP file to escalate privileges and execute commands with system privileges.CVE-2022-42972 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-42972"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users to update the affected product to the latest version. See Schneider Electric\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01-APC_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2022-42973",
"cwe": {
"id": "CWE-798",
"name": "Use of Hard-coded Credentials"
},
"notes": [
{
"category": "summary",
"text": "Schneider Electric APC Easy UPS Online versions 2.5-GA and prior use hard-coded MySQL database credentials. A local unauthorized user with access to the database could use the select into dumpfile operation to create arbitrary files, which could be used to execute commands with system privileges.CVE-2022-42973 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-42973"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users to update the affected product to the latest version. See Schneider Electric\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01-APC_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
SEVD-2022-347-01
Vulnerability from csaf_se - Published: 2022-12-13 06:09 - Updated: 2023-01-11 00:00A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022) <=2.5-GA
Schneider Electric / APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022)
|
<=2.5-GA |
Vendor Fix
fix
|
|
|
Schneider Electric APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022) <=2.5-GA-01-22261
Schneider Electric / APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022)
|
<=2.5-GA-01-22261 |
Vendor Fix
fix
|
|
|
Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022) <=2.5-GA
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022)
|
<=2.5-GA |
Vendor Fix
fix
|
|
|
Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022) <=2.5-GA-01-22261
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022)
|
<=2.5-GA-01-22261 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric APC Easy UPS Online Monitoring Software 2.5-GA-01-22320
Schneider Electric / APC Easy UPS Online Monitoring Software
|
2.5-GA-01-22320 | ||
|
Schneider Electric Easy UPS Online Monitoring Software 2.5-GA-01-22320
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software
|
2.5-GA-01-22320 |
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022) <=2.5-GA
Schneider Electric / APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022)
|
<=2.5-GA |
Vendor Fix
fix
|
|
|
Schneider Electric APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022) <=2.5-GA-01-22261
Schneider Electric / APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022)
|
<=2.5-GA-01-22261 |
Vendor Fix
fix
|
|
|
Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022) <=2.5-GA
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022)
|
<=2.5-GA |
Vendor Fix
fix
|
|
|
Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022) <=2.5-GA-01-22261
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022)
|
<=2.5-GA-01-22261 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric APC Easy UPS Online Monitoring Software 2.5-GA-01-22320
Schneider Electric / APC Easy UPS Online Monitoring Software
|
2.5-GA-01-22320 | ||
|
Schneider Electric Easy UPS Online Monitoring Software 2.5-GA-01-22320
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software
|
2.5-GA-01-22320 |
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022) <=2.5-GA
Schneider Electric / APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022)
|
<=2.5-GA |
Vendor Fix
fix
|
|
|
Schneider Electric APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022) <=2.5-GA-01-22261
Schneider Electric / APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022)
|
<=2.5-GA-01-22261 |
Vendor Fix
fix
|
|
|
Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022) <=2.5-GA
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022)
|
<=2.5-GA |
Vendor Fix
fix
|
|
|
Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022) <=2.5-GA-01-22261
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022)
|
<=2.5-GA-01-22261 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric APC Easy UPS Online Monitoring Software 2.5-GA-01-22320
Schneider Electric / APC Easy UPS Online Monitoring Software
|
2.5-GA-01-22320 | ||
|
Schneider Electric Easy UPS Online Monitoring Software 2.5-GA-01-22320
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software
|
2.5-GA-01-22320 |
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022) <=2.5-GA
Schneider Electric / APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022)
|
<=2.5-GA |
Vendor Fix
fix
|
|
|
Schneider Electric APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022) <=2.5-GA-01-22261
Schneider Electric / APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022)
|
<=2.5-GA-01-22261 |
Vendor Fix
fix
|
|
|
Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022) <=2.5-GA
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022)
|
<=2.5-GA |
Vendor Fix
fix
|
|
|
Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022) <=2.5-GA-01-22261
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022)
|
<=2.5-GA-01-22261 |
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric APC Easy UPS Online Monitoring Software 2.5-GA-01-22320
Schneider Electric / APC Easy UPS Online Monitoring Software
|
2.5-GA-01-22320 | ||
|
Schneider Electric Easy UPS Online Monitoring Software 2.5-GA-01-22320
Schneider Electric / Schneider Electric Easy UPS Online Monitoring Software
|
2.5-GA-01-22320 |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its APC Easy UPS Online Monitoring Software.\r\nThe APC Easy UPS Online Monitoring Software is used to configure and manage APC Easy UPS.\r\nFailure to apply the remediations provided below may risk remote code execution, escalation of privileges, or authentication bypass, which could result in execution of malicious web code or loss of device functionality.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "APC Easy UPS Online Monitoring Software - SEVD-2022-347-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf"
},
{
"category": "self",
"summary": "APC Easy UPS Online Monitoring Software - SEVD-2022-347-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2022-347-01.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "APC Easy UPS Online Monitoring Software",
"tracking": {
"current_release_date": "2023-01-11T00:00:00.000Z",
"generator": {
"date": "2023-01-11T00:00:00.000Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.1"
}
},
"id": "SEVD-2022-347-01",
"initial_release_date": "2022-12-13T06:09:04.000Z",
"revision_history": [
{
"date": "2022-12-13T06:09:04.000Z",
"number": "1",
"summary": "Original Release"
},
{
"date": "2023-01-11T00:00:00.000Z",
"number": "2",
"summary": "Schneider Electric Easy UPS Online Monitoring Software was added to the list of impacted products, and remediation links were updated."
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2.5-GA",
"product": {
"name": "Schneider Electric APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022) \u003c=2.5-GA",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2.5-GA-01-22261",
"product": {
"name": "Schneider Electric APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022) \u003c=2.5-GA-01-22261",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022)"
},
{
"branches": [
{
"category": "product_version",
"name": "2.5-GA-01-22320",
"product": {
"name": "Schneider Electric APC Easy UPS Online Monitoring Software 2.5-GA-01-22320",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "APC Easy UPS Online Monitoring Software"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2.5-GA",
"product": {
"name": "Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022) \u003c=2.5-GA",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 Windows Server 2016, 2019, 2022)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2.5-GA-01-22261",
"product": {
"name": "Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022) \u003c=2.5-GA-01-22261",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022)"
},
{
"branches": [
{
"category": "product_version",
"name": "2.5-GA-01-22320",
"product": {
"name": "Schneider Electric Easy UPS Online Monitoring Software 2.5-GA-01-22320",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Schneider Electric Easy UPS Online Monitoring Software "
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2022-42970",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"category": "description",
"text": "A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"6"
],
"known_affected": [
"1",
"2",
"4",
"5"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 2.5-GA-01-22320of APC Easy UPS Online Monitoring Software includes a fix for the vulnerabilities impacting Windows 7, 10, 11, and Windows Server 2016, 2019, and 2022 and is available for direct download here: https://download.schneider-electric.com/files?p_Doc_Ref=APC_install_APC_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installAPCUPS_windows-2.5-GA-01-22320.zip",
"product_ids": [
"1",
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=APC_install_APC_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installAPCUPS_windows-2.5-GA-01-22320.zip"
},
{
"category": "vendor_fix",
"details": "Version 2.5-GS-01-22320of Schneider Electric Easy UPS Online Monitoring Software includes a fix for the vulnerabilities impacting Windows 7, 10, 11, and Windows Server 2016, 2019, and 2022 and is available for direct download here: https://download.schneider-electric.com/files?p_Doc_Ref=Install_Schneider_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installSchneiderUPS_windows.zip",
"product_ids": [
"4",
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=Install_Schneider_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installSchneiderUPS_windows.zip"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"4",
"5"
]
}
],
"title": "CVE-2022-42970"
},
{
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2022-42971",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "description",
"text": "A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"6"
],
"known_affected": [
"1",
"2",
"4",
"5"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 2.5-GA-01-22320of APC Easy UPS Online Monitoring Software includes a fix for the vulnerabilities impacting Windows 7, 10, 11, and Windows Server 2016, 2019, and 2022 and is available for direct download here: https://download.schneider-electric.com/files?p_Doc_Ref=APC_install_APC_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installAPCUPS_windows-2.5-GA-01-22320.zip",
"product_ids": [
"1",
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=APC_install_APC_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installAPCUPS_windows-2.5-GA-01-22320.zip"
},
{
"category": "vendor_fix",
"details": "Version 2.5-GS-01-22320of Schneider Electric Easy UPS Online Monitoring Software includes a fix for the vulnerabilities impacting Windows 7, 10, 11, and Windows Server 2016, 2019, and 2022 and is available for direct download here: https://download.schneider-electric.com/files?p_Doc_Ref=Install_Schneider_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installSchneiderUPS_windows.zip",
"product_ids": [
"4",
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=Install_Schneider_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installSchneiderUPS_windows.zip"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"4",
"5"
]
}
],
"title": "CVE-2022-42971"
},
{
"acknowledgments": [
{
"names": [
"Piotr Bazydlo (@chudypb)"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2022-42972",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "description",
"text": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifies the webroot directory.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"6"
],
"known_affected": [
"1",
"2",
"4",
"5"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 2.5-GA-01-22320of APC Easy UPS Online Monitoring Software includes a fix for the vulnerabilities impacting Windows 7, 10, 11, and Windows Server 2016, 2019, and 2022 and is available for direct download here: https://download.schneider-electric.com/files?p_Doc_Ref=APC_install_APC_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installAPCUPS_windows-2.5-GA-01-22320.zip",
"product_ids": [
"1",
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=APC_install_APC_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installAPCUPS_windows-2.5-GA-01-22320.zip"
},
{
"category": "vendor_fix",
"details": "Version 2.5-GS-01-22320of Schneider Electric Easy UPS Online Monitoring Software includes a fix for the vulnerabilities impacting Windows 7, 10, 11, and Windows Server 2016, 2019, and 2022 and is available for direct download here: https://download.schneider-electric.com/files?p_Doc_Ref=Install_Schneider_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installSchneiderUPS_windows.zip",
"product_ids": [
"4",
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=Install_Schneider_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installSchneiderUPS_windows.zip"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"4",
"5"
]
}
],
"title": "CVE-2022-42972"
},
{
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2022-42973",
"cwe": {
"id": "CWE-798",
"name": "Use of Hard-coded Credentials"
},
"notes": [
{
"category": "description",
"text": "A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"3",
"6"
],
"known_affected": [
"1",
"2",
"4",
"5"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 2.5-GA-01-22320of APC Easy UPS Online Monitoring Software includes a fix for the vulnerabilities impacting Windows 7, 10, 11, and Windows Server 2016, 2019, and 2022 and is available for direct download here: https://download.schneider-electric.com/files?p_Doc_Ref=APC_install_APC_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installAPCUPS_windows-2.5-GA-01-22320.zip",
"product_ids": [
"1",
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=APC_install_APC_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installAPCUPS_windows-2.5-GA-01-22320.zip"
},
{
"category": "vendor_fix",
"details": "Version 2.5-GS-01-22320of Schneider Electric Easy UPS Online Monitoring Software includes a fix for the vulnerabilities impacting Windows 7, 10, 11, and Windows Server 2016, 2019, and 2022 and is available for direct download here: https://download.schneider-electric.com/files?p_Doc_Ref=Install_Schneider_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installSchneiderUPS_windows.zip",
"product_ids": [
"4",
"5"
],
"restart_required": {
"category": "none"
},
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=Install_Schneider_UPS_windows\u0026p_enDocType=Software+-+Release\u0026p_File_Name=installSchneiderUPS_windows.zip"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"4",
"5"
]
}
],
"title": "CVE-2022-42973"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.