CVE-2021-31892 (GCVE-0-2021-31892)
Vulnerability from cvelistv5 – Published: 2021-07-13 11:02 – Updated: 2024-08-03 23:10- CWE-295 - Improper Certificate Validation
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04 | x_refsource_MISC |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Siemens | SINUMERIK Analyse MyCondition |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Analyze MyPerformance |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Analyze MyPerformance /OEE-Monitor |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Analyze MyPerformance /OEE-Tuning |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Integrate Client 02 |
Affected:
All versions >= V02.00.12 < 02.00.18
|
guessed | |
| Siemens | SINUMERIK Integrate Client 03 |
Affected:
All versions >= V03.00.12 < 03.00.18
|
guessed | |
| Siemens | SINUMERIK Integrate Client 04 |
Affected:
V04.00.02 and all versions >= V04.00.15 < 04.00.18
|
guessed | |
| Siemens | SINUMERIK Integrate for Production 4.1 |
Affected:
All versions < V4.1 SP10 HF3
|
guessed | |
| Siemens | SINUMERIK Integrate for Production 5.1 |
Affected:
V5.1
|
guessed | |
| Siemens | SINUMERIK Manage MyMachines |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Manage MyMachines /Remote |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Manage MyMachines /Spindel Monitor |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Manage MyPrograms |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Manage MyResources /Programs |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Manage MyResources /Tools |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Manage MyTools |
Affected:
All versions
|
guessed | |
| Siemens | SINUMERIK Operate V4.8 |
Affected:
All versions < V4.8 SP8
|
guessed | |
| Siemens | SINUMERIK Operate V4.93 |
Affected:
All versions < V4.93 HF7
|
guessed | |
| Siemens | SINUMERIK Operate V4.94 |
Affected:
All versions < V4.94 HF5
|
guessed | |
| Siemens | SINUMERIK Optimize MyProgramming /NX-Cam Editor |
Affected:
All versions
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:10:30.735Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SINUMERIK Analyse MyCondition",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Analyze MyPerformance",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Analyze MyPerformance /OEE-Monitor",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Analyze MyPerformance /OEE-Tuning",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Integrate Client 02",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V02.00.12 \u003c 02.00.18"
}
]
},
{
"product": "SINUMERIK Integrate Client 03",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V03.00.12 \u003c 03.00.18"
}
]
},
{
"product": "SINUMERIK Integrate Client 04",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V04.00.02 and all versions \u003e= V04.00.15 \u003c 04.00.18"
}
]
},
{
"product": "SINUMERIK Integrate for Production 4.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1 SP10 HF3"
}
]
},
{
"product": "SINUMERIK Integrate for Production 5.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V5.1"
}
]
},
{
"product": "SINUMERIK Manage MyMachines",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Manage MyMachines /Remote",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Manage MyMachines /Spindel Monitor",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Manage MyPrograms",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Manage MyResources /Programs",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Manage MyResources /Tools",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Manage MyTools",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINUMERIK Operate V4.8",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP8"
}
]
},
{
"product": "SINUMERIK Operate V4.93",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.93 HF7"
}
]
},
{
"product": "SINUMERIK Operate V4.94",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.94 HF5"
}
]
},
{
"product": "SINUMERIK Optimize MyProgramming /NX-Cam Editor",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions \u003e= V02.00.12 \u003c 02.00.18), SINUMERIK Integrate Client 03 (All versions \u003e= V03.00.12 \u003c 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions \u003e= V04.00.15 \u003c 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions \u003c V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions \u003c V4.8 SP8), SINUMERIK Operate V4.93 (All versions \u003c V4.93 HF7), SINUMERIK Operate V4.94 (All versions \u003c V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295: Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-30T18:51:21.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-31892",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SINUMERIK Analyse MyCondition",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Analyze MyPerformance",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Analyze MyPerformance /OEE-Monitor",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Analyze MyPerformance /OEE-Tuning",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Integrate Client 02",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V02.00.12 \u003c 02.00.18"
}
]
}
},
{
"product_name": "SINUMERIK Integrate Client 03",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V03.00.12 \u003c 03.00.18"
}
]
}
},
{
"product_name": "SINUMERIK Integrate Client 04",
"version": {
"version_data": [
{
"version_value": "V04.00.02 and all versions \u003e= V04.00.15 \u003c 04.00.18"
}
]
}
},
{
"product_name": "SINUMERIK Integrate for Production 4.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1 SP10 HF3"
}
]
}
},
{
"product_name": "SINUMERIK Integrate for Production 5.1",
"version": {
"version_data": [
{
"version_value": "V5.1"
}
]
}
},
{
"product_name": "SINUMERIK Manage MyMachines",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Manage MyMachines /Remote",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Manage MyMachines /Spindel Monitor",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Manage MyPrograms",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Manage MyResources /Programs",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Manage MyResources /Tools",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Manage MyTools",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINUMERIK Operate V4.8",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.8 SP8"
}
]
}
},
{
"product_name": "SINUMERIK Operate V4.93",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.93 HF7"
}
]
}
},
{
"product_name": "SINUMERIK Operate V4.94",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.94 HF5"
}
]
}
},
{
"product_name": "SINUMERIK Optimize MyProgramming /NX-Cam Editor",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions \u003e= V02.00.12 \u003c 02.00.18), SINUMERIK Integrate Client 03 (All versions \u003e= V03.00.12 \u003c 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions \u003e= V04.00.15 \u003c 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions \u003c V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions \u003c V4.8 SP8), SINUMERIK Operate V4.93 (All versions \u003c V4.93 HF7), SINUMERIK Operate V4.94 (All versions \u003c V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-295: Improper Certificate Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-31892",
"datePublished": "2021-07-13T11:02:55.000Z",
"dateReserved": "2021-04-29T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:10:30.735Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-31892",
"date": "2026-11-17",
"epss": "0.00486",
"percentile": "0.42421"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinumerik_analyse_mycondition_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FA2214E8-9372-4709-BE00-8F7092AAADDD",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinumerik_analyse_mycondition:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A3B77B86-4A05-4341-B6D8-504470776A19",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinumerik_analyze_myperformance_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "71008661-4606-4CD9-8CD2-95A5FF43F911",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinumerik_analyze_myperformance:-:*:*:*:*:*:*:*",
"matchCriteriaId": "687D84BA-F629-4864-8CFC-FCBE5991F70E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinumerik_integrate_client_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "63B57057-5292-44D6-BC83-EA91B69F8748",
"versionEndExcluding": "2.00.18",
"versionStartIncluding": "2.00.12",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_integrate_client_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "42430844-AEA9-49A5-A91C-26994D01CEC4",
"versionEndExcluding": "3.00.18",
"versionStartIncluding": "3.00.12",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_integrate_client_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5BF11280-C660-48F2-806C-9521193CB7B6",
"versionEndExcluding": "4.00.18",
"versionStartIncluding": "4.00.15",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinumerik_integrate_client:-:*:*:*:*:*:*:*",
"matchCriteriaId": "60F7CAD2-5E95-4F98-BA6C-AB1BF8ECA8EF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinumerik_integrate_for_production_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "095D8D51-84B8-488D-8B1D-91E58B2FAEBB",
"versionEndIncluding": "4.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_integrate_for_production_firmware:5.1:*:*:*:*:*:*:*",
"matchCriteriaId": "05C78D0D-B572-4232-B64D-52FBF3308240",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinumerik_integrate_for_production:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B1DAE8F9-C0D4-45A8-A75A-F614439987F6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinumerik_manage_mymachines_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9AF20AC0-5E2D-4CC5-98EC-EDE0AAC52DD4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinumerik_manage_mymachines:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2DFAC74C-D52A-4460-BF2E-2B961830E32A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinumerik_manage_myprograms_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "28E2B9E8-78F1-4906-8165-0E32834E8123",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinumerik_manage_myprograms:-:*:*:*:*:*:*:*",
"matchCriteriaId": "41B51784-A56A-4E88-9D14-2A18FF3C839E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinumerik_manage_myresources_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E0B80A62-8568-4647-AFCA-E94769B314AE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinumerik_manage_myresources:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0682FAB1-35DC-477E-8A7B-FC749E3D08DF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinumerik_manage_mytools_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "10366A0A-CF45-409B-B3B4-4315613EBF62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinumerik_manage_mytools:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AEB2B1B8-FF09-438A-83CA-657E9FBAC5B4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D99EAD63-DFDC-4711-91A2-B5FCF578D76D",
"versionEndExcluding": "4.8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:-:*:*:*:*:*:*",
"matchCriteriaId": "FA7D3B00-F63E-4450-95A0-6B8E98B1BE07",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp1:*:*:*:*:*:*",
"matchCriteriaId": "56DDB3B0-66C6-44B1-8F49-B81817FCB7D9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp2:*:*:*:*:*:*",
"matchCriteriaId": "C27298EB-18D6-41B0-80E3-658CF5985669",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp3:*:*:*:*:*:*",
"matchCriteriaId": "E3AFA30D-7DBF-4828-AE94-9E19E073B158",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp4:*:*:*:*:*:*",
"matchCriteriaId": "6871C117-4D81-4BDA-98AC-48666B777686",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp5:*:*:*:*:*:*",
"matchCriteriaId": "AABA3AA8-E6BF-40A7-83FE-39DD8345C73D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp6:*:*:*:*:*:*",
"matchCriteriaId": "DF5E34D0-B29E-41EB-9256-3EDB6FE371F8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp7:*:*:*:*:*:*",
"matchCriteriaId": "E8AD951E-4CF5-4FE4-8254-D2FBFAF63342",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:-:*:*:*:*:*:*",
"matchCriteriaId": "B483C710-6220-41AB-85AD-FE1961F6FE01",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_1:*:*:*:*:*:*",
"matchCriteriaId": "9005DC09-271C-40BB-8084-8343388A0EE2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_2:*:*:*:*:*:*",
"matchCriteriaId": "2FF1AC69-917F-4A7D-A2DD-D226757786F1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_3:*:*:*:*:*:*",
"matchCriteriaId": "7CB684F1-DF4E-44D6-A340-2B020A814C8C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_4:*:*:*:*:*:*",
"matchCriteriaId": "55DA8893-DD8D-401A-A3C0-BD51C4C918DE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_5:*:*:*:*:*:*",
"matchCriteriaId": "3C447515-89F1-4BA8-BC92-2ABC4709FF09",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_6:*:*:*:*:*:*",
"matchCriteriaId": "810F9A19-0C8E-4954-BE00-6F9881206011",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:-:*:*:*:*:*:*",
"matchCriteriaId": "24DDF6F7-34CE-4CCA-8E46-3DB0A62D1205",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_1:*:*:*:*:*:*",
"matchCriteriaId": "5E99BB69-215E-498C-9B9C-F1298669D4E8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_2:*:*:*:*:*:*",
"matchCriteriaId": "F5206317-8F28-4230-AD8B-926C65EA7284",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_3:*:*:*:*:*:*",
"matchCriteriaId": "43E9CFDE-E7E5-4EAA-B023-FEBDE4E399FE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_4:*:*:*:*:*:*",
"matchCriteriaId": "E757E7DB-5358-456B-A897-B53C8615D489",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinumerik_operate:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C25600BA-6BD3-4E07-AFEF-AE5EF877CC25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sinumerik_optimize_myprogramming_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C4EAC9D5-32C9-418B-B993-A882F931CF90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sinumerik_optimize_myprogramming:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EC21335C-3D0B-4FFB-ADE9-6041835CA04E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions \u003e= V02.00.12 \u003c 02.00.18), SINUMERIK Integrate Client 03 (All versions \u003e= V03.00.12 \u003c 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions \u003e= V04.00.15 \u003c 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions \u003c V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions \u003c V4.8 SP8), SINUMERIK Operate V4.93 (All versions \u003c V4.93 HF7), SINUMERIK Operate V4.94 (All versions \u003c V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SINUMERIK Analyse MyCondition (Todas las versiones), SINUMERIK Analyze MyPerformance (Todas las versiones), SINUMERIK Analyze MyPerformance /OEE-Monitor (Todas las versiones), SINUMERIK Analyze MyPerformance /OEE-Tuning (Todas las versiones), SINUMERIK Integrate Client 02 (Todas las versiones posteriores a V02. 00.12 incluy\u00e9ndola, anteriores a 02.00.18), SINUMERIK Integrate Client 03 (Todas las versiones posteriores a V03.00.12 incluy\u00e9ndola, anteriores a 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 y todas las versiones posteriores a V04.00.15 incluy\u00e9ndola, anteriores a 04.00.18), SINUMERIK Integrate for Production 4.1 (Todas las versiones anteriores a V4.1 SP10 HF3), SINUMERIK Integrate for Production 5. 1 (V5. 1), SINUMERIK Manage MyMachines (Todas las versiones), SINUMERIK Manage MyMachines /Remote (Todas las versiones), SINUMERIK Manage MyMachines /Spindel Monitor (Todas las versiones), SINUMERIK Manage MyPrograms (Todas las versiones), SINUMERIK Manage MyResources /Programs (Todas las versiones), SINUMERIK Manage MyResources /Tools (Todas las versiones), SINUMERIK Manage MyTools (Todas las versiones), SINUMERIK Operate V4. 8 (Todas las versiones anteriores a V4.8 SP8), SINUMERIK Operate V4.93 (Todas las versiones anteriores a V4.93 HF7), SINUMERIK Operate V4.94 (Todas las versiones anteriores a V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (Todas las versiones). Debido a un error en una dependencia de terceros, los flags ssl usados para establecer una conexi\u00f3n TLS con un servidor se sobreescriben con una configuraci\u00f3n incorrecta. Esto resulta en una falta de comprobaci\u00f3n del certificado del servidor y, por tanto, a un posible escenario de TLS MITM"
}
],
"id": "CVE-2021-31892",
"lastModified": "2024-11-21T06:06:26.830",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-07-13T11:15:09.453",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-295"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T14:05:55+00:00",
"cve": "CVE-2021-31892",
"id": "CVE-2021-31892",
"initial_release_date": "2021-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2021-31892",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-31892.json",
"version": "3"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour