CVE-2021-22714 (GCVE-0-2021-22714)
Vulnerability from cvelistv5 – Published: 2021-03-11 20:13 – Updated: 2024-08-03 18:51- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0) |
Affected:
PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:06.841Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-11T20:13:56.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22714",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)",
"version": {
"version_data": [
{
"version_value": "PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22714",
"datePublished": "2021-03-11T20:13:56.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:06.841Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-22714",
"date": "2026-04-23",
"epss": "0.02269",
"percentile": "0.84691"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-22714\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-03-11T21:15:12.497\",\"lastModified\":\"2024-11-21T05:50:31.077\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.\"},{\"lang\":\"es\",\"value\":\"A CWE-119: se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de Operaciones dentro de los L\u00edmites de un B\u00fafer de la Memoria en PowerLogic ION7400, PM8000 e ION9000 (todas las versiones anteriores a V3.0.0), lo que podr\u00eda causar al medidor reiniciarse o permitir una ejecuci\u00f3n de c\u00f3digo remota\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0.0\",\"matchCriteriaId\":\"DCE7015C-02DD-44A1-ADEE-5E71CE312266\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0.0\",\"matchCriteriaId\":\"E5A75862-E1AC-4C6E-83AD-DE5FCD8BA50D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.0.0\",\"matchCriteriaId\":\"32067EA8-5153-4A00-9DE8-C4BEC42C00A6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6718EAAA-074D-4807-AC2D-DD0A06D397FB\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2021-068-02\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2021-068-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
CNVD-2021-31176
Vulnerability from cnvd - Published: 2021-04-26用户可参考如下厂商提供的安全补丁以修复该漏洞: https://www.se.com/ww/en/download/document/SEVD-2021-068-02
| Name | ['Schneider Electric PowerLogic ION9000 <V3.0.0', 'Schneider Electric PowerLogic PM8000 <V3.0.0', 'Schneider Electric PowerLogic ION7400 <V3.0.0'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2021-22714",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2021-22714"
}
},
"description": "Schneider Electric PowerLogic\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u4e2a\u5de5\u63a7\u8bbe\u5907\u3002\u63d0\u4f9b\u63d0\u9ad8\u529f\u7387\u56e0\u6570\u6765\u63d0\u9ad8\u7535\u6e90\u8d28\u91cf\uff0c\u6392\u9664\u7535\u6e90\u6545\u969c\uff0c\u4ece\u800c\u4fdd\u62a4\u7f51\u7edc\u3001\u88c5\u7f6e\u548c\u64cd\u4f5c\u5458\u3002\n\nPowerLogic ION7400\u3001PM8000\u548cION9000\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5bf9\u5185\u5b58\u7f13\u51b2\u533a\u5185\u64cd\u4f5c\u4e0d\u5f53\u9650\u5236\u3002\u653b\u51fb\u8005\u53ef\u901a\u8fc7\u53d1\u9001\u7279\u5236\u7684TCP\u6570\u636e\u5305\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u4eea\u8868\u91cd\u542f\u6216\u8fdc\u7a0b\u4ee3\u7801\u6267\u884c\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u5382\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u8865\u4e01\u4ee5\u4fee\u590d\u8be5\u6f0f\u6d1e\uff1a\r\nhttps://www.se.com/ww/en/download/document/SEVD-2021-068-02",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-31176",
"openTime": "2021-04-26",
"patchDescription": "Schneider Electric PowerLogic\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u4e2a\u5de5\u63a7\u8bbe\u5907\u3002\u63d0\u4f9b\u63d0\u9ad8\u529f\u7387\u56e0\u6570\u6765\u63d0\u9ad8\u7535\u6e90\u8d28\u91cf\uff0c\u6392\u9664\u7535\u6e90\u6545\u969c\uff0c\u4ece\u800c\u4fdd\u62a4\u7f51\u7edc\u3001\u88c5\u7f6e\u548c\u64cd\u4f5c\u5458\u3002\r\n\r\nPowerLogic ION7400\u3001PM8000\u548cION9000\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5bf9\u5185\u5b58\u7f13\u51b2\u533a\u5185\u64cd\u4f5c\u4e0d\u5f53\u9650\u5236\u3002\u653b\u51fb\u8005\u53ef\u901a\u8fc7\u53d1\u9001\u7279\u5236\u7684TCP\u6570\u636e\u5305\u5229\u7528\u8be5\u6f0f\u6d1e\u5bfc\u81f4\u4eea\u8868\u91cd\u542f\u6216\u8fdc\u7a0b\u4ee3\u7801\u6267\u884c\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric PowerLogic\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Schneider Electric PowerLogic ION9000 \u003cV3.0.0",
"Schneider Electric PowerLogic PM8000 \u003cV3.0.0",
"Schneider Electric PowerLogic ION7400 \u003cV3.0.0"
]
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2021-22714",
"serverity": "\u9ad8",
"submitTime": "2021-03-15",
"title": "Schneider Electric PowerLogic\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e"
}
SEVD-2021-068-02
Vulnerability from csaf_se - Published: 2021-03-09 00:00 - Updated: 2021-03-09 00:00CWE-119: Improper restriction of operations within the bounds of a memory buffer vulnerability exists that could cause the meter to reboot or allow for remote code execution.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its PowerLogic ION7400, PM8000 and ION9000\r\nproducts. \r\nThe PowerLogic metering products are revenue and power quality meters for utility and\r\nindustrial electrical network monitoring. \r\nFailure to apply the mitigations/remediations provided below may risk meter reboot or remote \r\ncode execution, which could result in unintended device behavior.",
"title": "Overview"
},
{
"category": "summary",
"text": "Customers should use appropriate methodologies when applying these upgrades to their devices. We strongly recommend evaluating the impact of these updates in a test and development environment prior to deployment. Contact Schneider Electric\u0027s Customer Care Center if you need assistance reverting to an older version of firmware. For alternative mitigations, customers should follow the General Security Recommendations provided below to reduce the risk of exploit.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "PowerLogic ION7400 / PM8000 / ION9000 Power Meters - SEVD-2021-068-02 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-068-02_PowerLogic_ION7400_PM8000_ION9000_Power_Meters_Security_Notification.pdf"
},
{
"category": "self",
"summary": "PowerLogic ION7400 / PM8000 / ION9000 Power Meters - SEVD-2021-068-02 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2021-068-02.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "PowerLogic ION7400 / PM8000 / ION9000 Power Meters",
"tracking": {
"current_release_date": "2021-03-09T00:00:00.000Z",
"generator": {
"date": "2021-03-09T00:00:00Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2021-068-02",
"initial_release_date": "2021-03-09T00:00:00.000Z",
"revision_history": [
{
"date": "2021-03-09T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.0.0",
"product": {
"name": "Schneider Electric ION7400 All versions prior to V3.0.0",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "ION7400"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.0.0",
"product": {
"name": "Schneider Electric ION9000 All versions prior to V3.0.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "ION9000"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c3.0.0",
"product": {
"name": "Schneider Electric PM8000 All versions prior to V3.0.0",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "PM8000"
},
{
"branches": [
{
"category": "product_version",
"name": "3.0.0",
"product": {
"name": "Schneider Electric PowerLogic ION7400 V3.0.0",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "PowerLogic ION7400"
},
{
"branches": [
{
"category": "product_version",
"name": "3.0.0",
"product": {
"name": "Schneider Electric ION9000 V3.0.0",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "ION9000"
},
{
"branches": [
{
"category": "product_version",
"name": "3.0.0",
"product": {
"name": "Schneider Electric PowerLogic PM8000 V3.0.0",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "PowerLogic PM8000"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Tal Keren",
"Rei Henigman"
],
"organization": "Claroty"
}
],
"cve": "CVE-2021-22714",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "description",
"text": "CWE-119: Improper restriction of operations within the bounds of a memory buffer\r\nvulnerability exists that could cause the meter to reboot or allow for remote code execution.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"4",
"5",
"6"
],
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "V3.0.0 (released 30 July 2020) of the PowerLogic ION7400 firmware \r\nincludes a fix for this vulnerability. The version update files are available \r\nfor download here: https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.000.000/ . Note: There may be newer versions of the firmware available for download, please check the ION7400: https://www.se.com/us/en/product-range-download/63502-powerlogic-ion7400-series/#/software-firmware-tab product page on before upgrading.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.000.000/"
},
{
"category": "vendor_fix",
"details": "V3.0.0 (released 30 July 2020) of the ION9000 firmware includes a fix \r\nfor this vulnerability. The version update files are available for download \r\nhere: available for download here: https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.000.000/ . There may be newer versions of the firmware available for download, please check the ION9000: https://www.se.com/us/en/product-range-download/64241-powerlogic-ion9000-series/#/software-firmware-tab product page before upgrading. ",
"product_ids": [
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.000.000/"
},
{
"category": "vendor_fix",
"details": "V3.0.0 (released 30 July 2020) of the PowerLogic PM8000 firmware \r\nincludes a fix for this vulnerability. The version update files are available \r\nfor download here: https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.000.000/ . There may be newer versions of the firmware available for download, please check the ION8000:https://www.se.com/us/en/product-range-download/62252-powerlogic-pm8000-series/#/software-firmware-tab product page before upgrading.",
"product_ids": [
"3"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.000.000/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2021-22714"
}
]
}
GSD-2021-22714
Vulnerability from gsd - Updated: 2023-12-13 01:23{
"GSD": {
"alias": "CVE-2021-22714",
"description": "A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.",
"id": "GSD-2021-22714"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-22714"
],
"details": "A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.",
"id": "GSD-2021-22714",
"modified": "2023-12-13T01:23:24.118070Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22714",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)",
"version": {
"version_data": [
{
"version_value": "PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22714"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-02-03T16:21Z",
"publishedDate": "2021-03-11T21:15Z"
}
}
}
BDU:2021-04271
Vulnerability from fstec - Published: 09.03.2021{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 3.0.0 (PowerLogic ION7400), \u0434\u043e 3.0.0 (PowerLogic ION9000), \u0434\u043e 3.0.0 (PowerLogic PM8000)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2021-068-02_PowerLogic_ION7400_PM8000_ION9000_Power_Meters_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2021-068-02",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "09.03.2021",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "30.08.2021",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "30.08.2021",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2021-04271",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2021-22714",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "PowerLogic ION7400, PowerLogic ION9000, PowerLogic PM8000",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0438\u0437\u043c\u0435\u0440\u0438\u0442\u0435\u043b\u0435\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0438 \u0441\u0447\u0435\u0442\u0447\u0438\u043a\u043e\u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438 PowerLogic ION7400, PM8000, ION9000, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u0432\u044b\u0445\u043e\u0434\u043e\u043c \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438 \u0437\u0430 \u0433\u0440\u0430\u043d\u0438\u0446\u044b \u0431\u0443\u0444\u0435\u0440\u0430 \u0432 \u043f\u0430\u043c\u044f\u0442\u0438, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043f\u0435\u0440\u0435\u0437\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0438\u043b\u0438 \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u0412\u044b\u0445\u043e\u0434 \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438 \u0437\u0430 \u0433\u0440\u0430\u043d\u0438\u0446\u044b \u0431\u0443\u0444\u0435\u0440\u0430 \u0432 \u043f\u0430\u043c\u044f\u0442\u0438 (CWE-119)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0438\u0437\u043c\u0435\u0440\u0438\u0442\u0435\u043b\u0435\u0439 \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u0438 \u0438 \u0441\u0447\u0435\u0442\u0447\u0438\u043a\u043e\u0432 \u044d\u043b\u0435\u043a\u0442\u0440\u043e\u044d\u043d\u0435\u0440\u0433\u0438\u0438 PowerLogic ION7400, PM8000, ION9000 \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u0432\u044b\u0445\u043e\u0434\u043e\u043c \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u0438 \u0437\u0430 \u0433\u0440\u0430\u043d\u0438\u0446\u044b \u0431\u0443\u0444\u0435\u0440\u0430 \u0432 \u043f\u0430\u043c\u044f\u0442\u0438. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043f\u0435\u0440\u0435\u0437\u0430\u0433\u0440\u0443\u0437\u043a\u0443 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432\u0430 \u0438\u043b\u0438 \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430\u043c\u0438 \u0434\u0430\u043d\u043d\u044b\u0445",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2021-068-02_PowerLogic_ION7400_PM8000_ION9000_Power_Meters_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2021-068-02",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u0421\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-119",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 10)\n\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 9,8)"
}
GHSA-R3VQ-3892-G6RC
Vulnerability from github – Published: 2022-05-24 17:44 – Updated: 2022-05-24 17:44A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.
{
"affected": [],
"aliases": [
"CVE-2021-22714"
],
"database_specific": {
"cwe_ids": [
"CWE-119"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-03-11T21:15:00Z",
"severity": "CRITICAL"
},
"details": "A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.",
"id": "GHSA-r3vq-3892-g6rc",
"modified": "2022-05-24T17:44:16Z",
"published": "2022-05-24T17:44:16Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-22714"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02"
}
],
"schema_version": "1.4.0",
"severity": []
}
VAR-202103-0445
Vulnerability from variot - Updated: 2024-11-23 22:51A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution. plural Schneider Electric The product contains a buffer error vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Schneider Electric PowerLogic is an industrial control equipment of French Schneider Electric (Schneider Electric) company. Provide improved power factor to improve power quality, eliminate power failures, thereby protecting the network, devices and operators.
PowerLogic ION7400, PM8000 and ION9000 have a buffer overflow vulnerability, which stems from improper restrictions on operations in the memory buffer
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202103-0445",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "powerlogic ion9000",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.0.0"
},
{
"model": "powerlogic pm8000",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.0.0"
},
{
"model": "powerlogic ion7400",
"scope": "lt",
"trust": 1.0,
"vendor": "schneider electric",
"version": "3.0.0"
},
{
"model": "powerlogic ion7400",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "powerlogic pm8000",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "powerlogic ion9000",
"scope": null,
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "electric powerlogic ion9000",
"scope": "lt",
"trust": 0.6,
"vendor": "schneider",
"version": "v3.0.0"
},
{
"model": "electric powerlogic pm8000",
"scope": "lt",
"trust": 0.6,
"vendor": "schneider",
"version": "v3.0.0"
},
{
"model": "electric powerlogic ion7400",
"scope": "lt",
"trust": 0.6,
"vendor": "schneider",
"version": "v3.0.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31176"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004653"
},
{
"db": "NVD",
"id": "CVE-2021-22714"
}
]
},
"cve": "CVE-2021-22714",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2021-22714",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-31176",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2021-22714",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-22714",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-22714",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2021-22714",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2021-31176",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202103-827",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31176"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004653"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-827"
},
{
"db": "NVD",
"id": "CVE-2021-22714"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution. plural Schneider Electric The product contains a buffer error vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Schneider Electric PowerLogic is an industrial control equipment of French Schneider Electric (Schneider Electric) company. Provide improved power factor to improve power quality, eliminate power failures, thereby protecting the network, devices and operators. \n\r\n\r\nPowerLogic ION7400, PM8000 and ION9000 have a buffer overflow vulnerability, which stems from improper restrictions on operations in the memory buffer",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22714"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004653"
},
{
"db": "CNVD",
"id": "CNVD-2021-31176"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-22714",
"trust": 3.0
},
{
"db": "SCHNEIDER",
"id": "SEVD-2021-068-02",
"trust": 1.6
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004653",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-31176",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202103-827",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31176"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004653"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-827"
},
{
"db": "NVD",
"id": "CVE-2021-22714"
}
]
},
"id": "VAR-202103-0445",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31176"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31176"
}
]
},
"last_update_date": "2024-11-23T22:51:06.810000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SEVD-2021-068-02",
"trust": 0.8,
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02"
},
{
"title": "Patch for Schneider Electric PowerLogic buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/261431"
},
{
"title": "Schneider Electric PowerLogic Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=144835"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31176"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004653"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-827"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ Other ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004653"
},
{
"db": "NVD",
"id": "CVE-2021-22714"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-22714"
},
{
"trust": 1.6,
"url": "https://www.se.com/ww/en/download/document/sevd-2021-068-02"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31176"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004653"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-827"
},
{
"db": "NVD",
"id": "CVE-2021-22714"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-31176"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004653"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-827"
},
{
"db": "NVD",
"id": "CVE-2021-22714"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-31176"
},
{
"date": "2021-11-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-004653"
},
{
"date": "2021-03-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-827"
},
{
"date": "2021-03-11T21:15:12.497000",
"db": "NVD",
"id": "CVE-2021-22714"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-31176"
},
{
"date": "2021-11-25T08:23:00",
"db": "JVNDB",
"id": "JVNDB-2021-004653"
},
{
"date": "2022-03-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-827"
},
{
"date": "2024-11-21T05:50:31.077000",
"db": "NVD",
"id": "CVE-2021-22714"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-827"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Schneider\u00a0Electric\u00a0 Buffer error vulnerability in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004653"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-827"
}
],
"trust": 0.6
}
}
CERTFR-2021-AVI-175
Vulnerability from certfr_avis - Published: 2021-03-10 - Updated: 2021-03-10
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | IGSS Definition (Def.exe) version antérieures à 15.0.0.21042 | ||
| N/A | N/A | ION7400 versions antérieures à 3.0.0 | ||
| N/A | N/A | ION8650 versions antérieures à 4.40.1 | ||
| N/A | N/A | ION8800 versions antérieures à 372 | ||
| N/A | N/A | ION7650 (Hardware rev. 5*) versions antérieures à 416 | ||
| N/A | N/A | PM8000 versions antérieures à 3.0.0 | ||
| N/A | N/A | ION7700/73xx toutes versions | ||
| N/A | N/A | ION83xx/84xx/85xx/8600 toutes versions | ||
| N/A | N/A | ION7650 (Hardware rev. 4 or earlier*) versions antérieures à 376 | ||
| N/A | N/A | ION9000 versions antérieures à 3.0.0 |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "IGSS Definition (Def.exe) version ant\u00e9rieures \u00e0 15.0.0.21042",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7400 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION8650 versions ant\u00e9rieures \u00e0 4.40.1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION8800 versions ant\u00e9rieures \u00e0 372",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7650 (Hardware rev. 5*) versions ant\u00e9rieures \u00e0 416",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PM8000 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7700/73xx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION83xx/84xx/85xx/8600 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION7650 (Hardware rev. 4 or earlier*) versions ant\u00e9rieures \u00e0 376",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ION9000 versions ant\u00e9rieures \u00e0 3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-22712",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22712"
},
{
"name": "CVE-2021-22709",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22709"
},
{
"name": "CVE-2021-22713",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22713"
},
{
"name": "CVE-2021-22710",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22710"
},
{
"name": "CVE-2021-22714",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22714"
},
{
"name": "CVE-2021-22711",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22711"
}
],
"initial_release_date": "2021-03-10T00:00:00",
"last_revision_date": "2021-03-10T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-175",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-03-10T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-068-02 du 09 mars 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-068-01 du 09 mars 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-068-03 du 09 mars 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-068-03"
}
]
}
FKIE_CVE-2021-22714
Vulnerability from fkie_nvd - Published: 2021-03-11 21:15 - Updated: 2024-11-21 05:50{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DCE7015C-02DD-44A1-ADEE-5E71CE312266",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E5A75862-E1AC-4C6E-83AD-DE5FCD8BA50D",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "32067EA8-5153-4A00-9DE8-C4BEC42C00A6",
"versionEndExcluding": "3.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6718EAAA-074D-4807-AC2D-DD0A06D397FB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution."
},
{
"lang": "es",
"value": "A CWE-119: se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de Operaciones dentro de los L\u00edmites de un B\u00fafer de la Memoria en PowerLogic ION7400, PM8000 e ION9000 (todas las versiones anteriores a V3.0.0), lo que podr\u00eda causar al medidor reiniciarse o permitir una ejecuci\u00f3n de c\u00f3digo remota"
}
],
"id": "CVE-2021-22714",
"lastModified": "2024-11-21T05:50:31.077",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-03-11T21:15:12.497",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-02"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.