CVE-2020-15782 (GCVE-0-2020-15782)
Vulnerability from cvelistv5 – Published: 2021-05-28 16:10 – Updated: 2026-06-02 18:50- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Siemens | SIMATIC Drive Controller family |
Affected:
All versions < V2.9.2
|
guessed | |
| Siemens | SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) |
Affected:
All versions
|
guessed | |
| Siemens | SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) |
Affected:
All versions < V21.9
|
guessed | |
| Siemens | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) |
Affected:
All versions < V4.5.0
|
guessed | |
| Siemens | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) |
Affected:
All versions < V2.9.2
|
guessed | |
| Siemens | SIMATIC S7-1500 Software Controller |
Affected:
All versions < V21.9
|
guessed | |
| Siemens | SIMATIC S7-PLCSIM Advanced |
Affected:
All versions < V4.0
|
guessed | |
| Siemens | SINAMICS PERFECT HARMONY GH180 Drives |
Affected:
Drives manufactured before 2021-08-13
|
guessed | |
| Siemens | SINUMERIK MC |
Affected:
All versions < V6.15
|
guessed | |
| Siemens | SINUMERIK ONE |
Affected:
All versions < V6.15
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:22:30.758Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-15782",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T18:50:27.467629Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T18:50:38.536Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.2"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9"
}
]
},
{
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5.0"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.2"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9"
}
]
},
{
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.0"
}
]
},
{
"product": "SINAMICS PERFECT HARMONY GH180 Drives",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "Drives manufactured before 2021-08-13"
}
]
},
{
"product": "SINUMERIK MC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.15"
}
]
},
{
"product": "SINUMERIK ONE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.15"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions \u003c V6.15), SINUMERIK ONE (All versions \u003c V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-14T10:47:06.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-15782",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC Drive Controller family",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.9.2"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V21.9"
}
]
}
},
{
"product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.5.0"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.9.2"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V21.9"
}
]
}
},
{
"product_name": "SIMATIC S7-PLCSIM Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.0"
}
]
}
},
{
"product_name": "SINAMICS PERFECT HARMONY GH180 Drives",
"version": {
"version_data": [
{
"version_value": "Drives manufactured before 2021-08-13"
}
]
}
},
{
"product_name": "SINUMERIK MC",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V6.15"
}
]
}
},
{
"product_name": "SINUMERIK ONE",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V6.15"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions \u003c V6.15), SINUMERIK ONE (All versions \u003c V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-15782",
"datePublished": "2021-05-28T16:10:10.000Z",
"dateReserved": "2020-07-15T00:00:00.000Z",
"dateUpdated": "2026-06-02T18:50:38.536Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-15782",
"date": "2026-11-15",
"epss": "0.05184",
"percentile": "0.92592"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_driver_controller_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A7B8C5FB-3BF8-4A74-AB58-474D754CFBBA",
"versionEndExcluding": "2.9.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cpu_1504d_tf:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6150A06A-0EB8-46CC-A118-2E70BF183CFE",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:cpu_1507d_tf:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1F33CBC2-330D-4791-9BAB-ECEF3720BBC0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:s7-1200_cpu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6852AC11-6388-4D26-923E-DB8933F05EDC",
"versionEndExcluding": "4.5.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cpu_1211c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "172D341B-D863-4C24-9B6E-633EBE87C8C9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:cpu_1212c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1B475E4F-EE4F-4435-9F0B-8E4FA35377BE",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:cpu_1212fc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1402D624-5AF3-4E25-A2B0-9D9F214EE8FE",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:cpu_1214c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1F714315-8BEB-4BD3-BE59-C6649A0A105E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:cpu_1214fc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2A988C9F-60DF-4BC5-A890-F03F445DD9BD",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:cpu_1215c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C90820D3-3F3E-4DC4-9DCE-A498CC26268D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:cpu_1215fc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BAF22AB6-6DAA-4983-99DB-4F2A2E76856F",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:cpu_1217c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4C95F12D-563A-4915-9F26-A461EB4F8FA1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:s7-1500_cpu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7D8BEAD8-461A-4832-8BF7-9F2CE8ADB6BC",
"versionEndExcluding": "2.9.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6es7510-1dj01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0645616B-B515-49BE-9C9A-33A0E9E7C108",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7510-1sj01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8D11FF81-01F3-4B07-B57C-8B43DAD3640A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7511-1ak01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B9FFB12A-E3B7-4273-AAAF-0AECB9BB69C0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7511-1ak02-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "25A19AB0-CCC8-4513-8182-68CE66F136F1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7511-1ck00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DED5460A-76CF-4830-AAFB-A10CE7EFD129",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7511-1ck01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "207FD076-F2B7-4DE5-8390-E135A09DBD26",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7511-1fk01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF0FB5A5-A930-4635-B483-991611967E1E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7511-1fk02-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7F039613-55B4-45E9-9E12-9603DF424A6A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7511-1tk01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BA18592B-0624-4C06-AC5E-1336E9E02C11",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7511-1uk01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F3C00821-4873-4B80-ADC5-FED9FFD810DC",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7512-1ck00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4E4D7484-F6E9-4A5C-9695-691FC48D602C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7512-1ck01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE762064-FE24-4A1D-94DA-7411CC701B8A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7512-1dk01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2A1B45F7-14BA-45B5-AE0F-25F4E77CB40E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7512-1sk01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC5C0BB0-A443-4764-9A9F-828882556665",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7513-1al01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7CC9DB1B-DDAC-4FD2-BB9E-F64941C14E58",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7513-1al02-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1C01A87E-E18E-4E83-BCC5-AAE48E177B96",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7513-1fl01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5426F764-765B-4E80-86D5-A86EF95A53F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7513-1fl02-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F16BF979-9B89-42C9-8B5D-2A9F5E76F10E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7513-1rl00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D7FC9267-B12D-4E13-BEB5-7D61989C1047",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7513-2gl00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "91E3A8F5-7BC8-43C5-84D9-00DCEB4D4E05",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7513-2pl00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CAA520E3-A01E-441C-95B3-B3481C4405C4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7515-2am01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DBFB9E73-59C8-4E05-ABDD-335315EE37CD",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7515-2am02-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "225036D8-E501-4069-9D30-C243AE79CA2B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7515-2fm01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "69F4097E-27F4-43EB-81E7-BD497477396F",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7515-2fm02-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CF247FF5-E912-44E1-8D0A-781912797783",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7515-2rm00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B707B729-AEF1-446D-9E85-5504BF098635",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7515-2tm01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6DD88AAE-1926-47AA-9071-E657053D9A91",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7515-2um01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C71F8606-63FC-4BC6-830C-1FF19B30110A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7516-2gn00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DEA0DD75-F6B4-41A7-A9AA-03FAFAA38B16",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7516-2pn00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1CBB9517-4F18-4CB9-B7F3-4D30D6E9DCE2",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7516-3an01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "56C07F7B-5042-44BA-B5F3-438A60A776D7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7516-3an02-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9D2412B1-8ADC-48AC-85CF-BAE6E3674B29",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7516-3fn01-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B6F8F1FC-3F9A-48B0-A6EE-9AB66AB4A1E5",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7516-3fn02-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BC0DCCCE-1348-48FC-BD48-0D23F4A8A69D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7516-3tn00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E728548F-2F18-4BF4-8A32-83CBAE2D5A12",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7516-3un00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BE4AEE6E-03BA-4302-9D77-FC3102A216E9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7517-3ap00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C49DB60C-69FB-4251-9185-02CABCB66E86",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7517-3fp00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5628EB18-2D21-40F2-ACCC-65EF5D9A5BB3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7517-3hp00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2E341A3B-D0F6-49EC-AE13-CC2D0DA6AF15",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7517-3tp00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BD084757-FD90-45BA-96D2-F885741EE205",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7517-3up00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1A49F3BE-3391-423F-9EBC-5DAEB1A33C06",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7518-4ap00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A40D89C7-A781-407A-B675-507E3211EB38",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7518-4ap00-3ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "91BAF17B-E442-48E2-8484-547CB4375213",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7518-4fp00-0ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F17DE4F0-A475-4F08-99A5-36744978FEB2",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:6es7518-4fp00-3ab0:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BC059287-41DD-4926-A17A-ED256541AD28",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-1500__software_controller:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6745F8B-D98C-4410-AB01-CE6EE3DDCB4A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E58BF80D-955E-44DE-B376-FC632C197390",
"versionEndExcluding": "4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:et_200sp_open_controller_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1EA915A3-BC37-4907-8207-AD3B2E4C488F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:cpu_1515sp_pc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2F01ED37-3930-48BD-B911-388775A1715A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:siemens:cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "02DE6F0F-C1FD-4007-AFA4-12F79C8DF1EC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions \u003c V6.15), SINUMERIK ONE (All versions \u003c V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en la familia SIMATIC Drive Controller (Todas las versiones anteriores a la versi\u00f3n V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incluyendo las variantes SIPLUS) (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V21.9), familia SIMATIC S7-1200 CPU (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V4.5.0), familia SIMATIC S7-1500 CPU (incluyendo CPU ET200 relacionadas y variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V2.9.2), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versi\u00f3n V21.9), SIMATIC S7-PLCSIM Advanced (Todas las versiones anteriores a la versi\u00f3n V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Unidades fabricadas antes de 2021-08-13), SINUMERIK MC (Todas las versiones anteriores a la versi\u00f3n V6.15), SINUMERIK ONE (Todas las versiones anteriores a la versi\u00f3n V6.15). Los dispositivos afectados son vulnerables a una omisi\u00f3n de protecci\u00f3n de la memoria mediante una operaci\u00f3n espec\u00edfica. Un atacante remoto no autenticado con acceso de red al puerto 102/tcp podr\u00eda potencialmente escribir datos y c\u00f3digo arbitrario en \u00e1reas de memoria protegidas o leer datos confidenciales para iniciar m\u00e1s ataques"
}
],
"id": "CVE-2020-15782",
"lastModified": "2026-06-02T20:16:24.350",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2021-05-28T16:15:07.790",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:22:30.758Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2020-15782",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T18:50:27.467629Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T18:47:15.637Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC Drive Controller family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.2"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9"
}
]
},
{
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5.0"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.9.2"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V21.9"
}
]
},
{
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.0"
}
]
},
{
"product": "SINAMICS PERFECT HARMONY GH180 Drives",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "Drives manufactured before 2021-08-13"
}
]
},
{
"product": "SINUMERIK MC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.15"
}
]
},
{
"product": "SINUMERIK ONE",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.15"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions \u003c V6.15), SINUMERIK ONE (All versions \u003c V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-14T10:47:06.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-15782",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC Drive Controller family",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.9.2"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V21.9"
}
]
}
},
{
"product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.5.0"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.9.2"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V21.9"
}
]
}
},
{
"product_name": "SIMATIC S7-PLCSIM Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.0"
}
]
}
},
{
"product_name": "SINAMICS PERFECT HARMONY GH180 Drives",
"version": {
"version_data": [
{
"version_value": "Drives manufactured before 2021-08-13"
}
]
}
},
{
"product_name": "SINUMERIK MC",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V6.15"
}
]
}
},
{
"product_name": "SINUMERIK ONE",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V6.15"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SINAMICS PERFECT HARMONY GH180 Drives (Drives manufactured before 2021-08-13), SINUMERIK MC (All versions \u003c V6.15), SINUMERIK ONE (All versions \u003c V6.15). Affected devices are vulnerable to a memory protection bypass through a specific operation. A remote unauthenticated attacker with network access to port 102/tcp could potentially write arbitrary data and code to protected memory areas or read sensitive data to launch further attacks."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434534.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-15782",
"datePublished": "2021-05-28T16:10:10.000Z",
"dateReserved": "2020-07-15T00:00:00.000Z",
"dateUpdated": "2026-06-02T18:50:38.536Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.