CVE-2020-14523 (GCVE-0-2020-14523)

Vulnerability from cvelistv5 – Published: 2022-02-11 17:40 – Updated: 2025-04-16 18:01
VLAI
Title
Mitsubishi Electric Factory Automation Products Path Traversal
Summary
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 17:31 UTC
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Impacted products
Vendor Product Version CPE status
Mitsubishi Electric CW Configurator Affected: unspecified , ≤ Version 1.010L (custom)
guessed Create a notification for this product.
Mitsubishi Electric FR Configurator2 Affected: unspecified , ≤ Version 1.22Y (custom)
guessed Create a notification for this product.
Mitsubishi Electric GX Works2 Affected: unspecified , ≤ Version 1.595V (custom)
guessed Create a notification for this product.
Mitsubishi Electric GX Works3 Affected: unspecified , ≤ Version 1.063R (custom)
guessed Create a notification for this product.
Mitsubishi Electric MELSOFT iQ AppPortal Affected: unspecified , ≤ Version 1.17T (custom)
guessed Create a notification for this product.
Mitsubishi Electric MELSOFT Navigator Affected: unspecified , ≤ Version2.70Y (custom)
guessed Create a notification for this product.
Mitsubishi Electric MI Configurator Affected: All Versions
guessed Create a notification for this product.
Mitsubishi Electric MR Configurator2 Affected: unspecified , ≤ Version 1.110Q (custom)
guessed Create a notification for this product.
Mitsubishi Electric MT Works2 Affected: unspecified , ≤ Versions 1.156N (custom)
guessed Create a notification for this product.
Mitsubishi Electric MX Component Affected: unspecified , ≤ Version 4.20W (custom)
guessed Create a notification for this product.
Mitsubishi Electric RT ToolBox3 Affected: unspecified , ≤ Versions 1.70Y (custom)
guessed Create a notification for this product.
Mitsubishi Electric MELSEC iQ-R Series Motion Module Affected: unspecified , ≤ Versions 10 (custom)
guessed Create a notification for this product.
Date Public
2020-07-30 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:46:34.640Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU90224831/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-14523",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:31:26.782063Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T18:01:22.616Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CW Configurator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.010L",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "FR Configurator2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.22Y",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.595V",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.063R",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MELSOFT iQ AppPortal",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.17T",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MELSOFT Navigator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version2.70Y",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MI Configurator",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        },
        {
          "product": "MR Configurator2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 1.110Q",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MT Works2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Versions 1.156N",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MX Component",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Version 4.20W",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "RT ToolBox3",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Versions 1.70Y",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "MELSEC iQ-R Series Motion Module",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "lessThanOrEqual": "Versions 10",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
        }
      ],
      "datePublic": "2020-07-30T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-18T23:17:23.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/vu/JVNVU90224831/"
        }
      ],
      "source": {
        "advisory": "ICSA-20-212-03",
        "discovery": "UNKNOWN"
      },
      "title": "Mitsubishi Electric Factory Automation Products Path Traversal",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2020-07-30T16:50:00.000Z",
          "ID": "CVE-2020-14523",
          "STATE": "PUBLIC",
          "TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CW Configurator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.010L"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "FR Configurator2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.22Y"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX Works2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.595V"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GX Works3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.063R"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT iQ AppPortal",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.17T"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSOFT Navigator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version2.70Y"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MI Configurator",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "All Versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MR Configurator2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 1.110Q"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MT Works2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Versions 1.156N"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MX Component",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Version 4.20W"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "RT ToolBox3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Versions 1.70Y"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MELSEC iQ-R Series Motion Module",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "Versions 10"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mitsubishi Electric"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
            },
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf",
              "refsource": "MISC",
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
            },
            {
              "name": "https://jvn.jp/vu/JVNVU90224831/",
              "refsource": "MISC",
              "url": "https://jvn.jp/vu/JVNVU90224831/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en"
          }
        ],
        "source": {
          "advisory": "ICSA-20-212-03",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-14523",
    "datePublished": "2022-02-11T17:40:29.187Z",
    "dateReserved": "2020-06-19T00:00:00.000Z",
    "dateUpdated": "2025-04-16T18:01:22.616Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-14523",
      "date": "2026-10-01",
      "epss": "0.02254",
      "percentile": "0.82313"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "892E3CDC-AFC4-4EF1-AF46-3F161603DDB1",
                    "versionEndIncluding": "1.010l",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "87549502-D224-408D-8C66-41F5E8F7743A",
                    "versionEndIncluding": "1.22y",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "015EB163-A5D6-4C55-8038-59823B7FF49F",
                    "versionEndIncluding": "1.595v",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AE537EF6-72AE-4091-AF6E-9959C3F45632",
                    "versionEndIncluding": "1.063r",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:iu_configuration_tool:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "83B09E17-9CFF-4231-AE28-FB9D99332BCB",
                    "versionEndIncluding": "1.04",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:iu_developer2:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D449D560-C64A-48B0-B1BB-31800FF3062E",
                    "versionEndIncluding": "1.08",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8F2EA556-367B-4F32-99D2-C685742CCAEE",
                    "versionEndIncluding": "1.17t",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FF88C6B0-5641-488E-9AE2-6AF479EB10BF",
                    "versionEndIncluding": "2.70y",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "50DAB8A0-E2F3-496A-B6B6-22E4243D104C",
                    "versionEndIncluding": "1.110q",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "04FF09A2-B1C0-4A65-A420-22A044B7F2CD",
                    "versionEndIncluding": "1.156n",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A0C9B5B3-D4F6-4E00-89B4-964516BB989B",
                    "versionEndIncluding": "4.20w",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "463E3740-A618-45A6-9C30-6FBC28077123",
                    "versionEndIncluding": "1.70y",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:rd78g4_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BEAB1838-A2E2-4D12-A216-68DD9E4624CF",
                    "versionEndIncluding": "10",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:rd78g4:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B9B1BA74-5B02-400C-AA98-AFB29E848299",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:rd78g8_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E213C893-9C88-42C1-BE32-634D7BB84AD6",
                    "versionEndIncluding": "10",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:rd78g8:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8467C47A-2798-43FA-B132-A774B1148FC0",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:rd78g16_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "389EBE60-F4CF-4E82-975D-44DCBAC74929",
                    "versionEndIncluding": "10",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:rd78g16:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5F671BBC-41EE-41FF-87B1-36DBFA7A4BAD",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:rd78g32_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2325BC60-32F9-46CA-8035-7E88360C15A1",
                    "versionEndIncluding": "10",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:rd78g32:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "81DD3BFA-9E3A-4FAB-AB7B-6CC365628877",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:rd78g64_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DC759E3E-6D0A-4BA5-AB2E-38947331C5B2",
                    "versionEndIncluding": "10",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:rd78g64:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F0A92E26-C302-4285-BED1-7B8637E252DA",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghv_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D70552B7-C943-43B0-B5BD-ED43A853657E",
                    "versionEndIncluding": "10",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghv:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "12E5533D-15A8-471B-899B-FE9F9655EE8F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghw_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BA2C0DCD-65E6-4B93-B92F-E4FE46CCA58C",
                    "versionEndIncluding": "10",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghw:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8B5C3119-7579-4623-8513-65A281BDF0D1",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
          },
          {
            "lang": "es",
            "value": "diversos productos de Mitsubishi Electric Factory Automation presentan una vulnerabilidad que permite a un atacante ejecutar c\u00f3digo arbitrario"
          }
        ],
        "id": "CVE-2020-14523",
        "lastModified": "2024-11-21T05:03:27.300",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.6,
              "impactScore": 6.0,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2022-02-11T18:15:08.577",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://jvn.jp/vu/JVNVU90224831/"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Patch",
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://jvn.jp/vu/JVNVU90224831/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-22"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-22"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T12:46:34.640Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/vu/JVNVU90224831/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-14523",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T17:31:26.782063Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T17:31:28.177Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CW Configurator",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.010L",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "FR Configurator2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.22Y",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "GX Works2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.595V",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "GX Works3",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.063R",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MELSOFT iQ AppPortal",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.17T",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MELSOFT Navigator",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version2.70Y",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MI Configurator",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions"
                }
              ]
            },
            {
              "product": "MR Configurator2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 1.110Q",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MT Works2",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Versions 1.156N",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MX Component",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Version 4.20W",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "RT ToolBox3",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Versions 1.70Y",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "MELSEC iQ-R Series Motion Module",
              "vendor": "Mitsubishi Electric",
              "versions": [
                {
                  "lessThanOrEqual": "Versions 10",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
            }
          ],
          "datePublic": "2020-07-30T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-18T23:17:23.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/vu/JVNVU90224831/"
            }
          ],
          "source": {
            "advisory": "ICSA-20-212-03",
            "discovery": "UNKNOWN"
          },
          "title": "Mitsubishi Electric Factory Automation Products Path Traversal",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2020-07-30T16:50:00.000Z",
              "ID": "CVE-2020-14523",
              "STATE": "PUBLIC",
              "TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CW Configurator",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.010L"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "FR Configurator2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.22Y"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "GX Works2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.595V"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "GX Works3",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.063R"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MELSOFT iQ AppPortal",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.17T"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MELSOFT Navigator",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version2.70Y"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MI Configurator",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "All Versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MR Configurator2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 1.110Q"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MT Works2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Versions 1.156N"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MX Component",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Version 4.20W"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "RT ToolBox3",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Versions 1.70Y"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MELSEC iQ-R Series Motion Module",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "Versions 10"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Mitsubishi Electric"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Mashav Sapir of Claroty reported this vulnerability to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03"
                },
                {
                  "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf"
                },
                {
                  "name": "https://jvn.jp/vu/JVNVU90224831/",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/vu/JVNVU90224831/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en"
              }
            ],
            "source": {
              "advisory": "ICSA-20-212-03",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2020-14523",
        "datePublished": "2022-02-11T17:40:29.187Z",
        "dateReserved": "2020-06-19T00:00:00.000Z",
        "dateUpdated": "2025-04-16T18:01:22.616Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…