Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2019-10929 (GCVE-0-2019-10929)
Vulnerability from cvelistv5 – Published: 2019-08-13 18:55 – Updated: 2024-08-04 22:40- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://www.us-cert.gov/ics/advisories/icsa-19-344-04 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.230Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V20.8"
}
]
},
{
"product": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.8.1"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V20.8"
}
]
},
{
"product": "SIMATIC S7-PLCSIM Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"product": "SIMATIC STEP 7 (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC OA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.16 P013"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16"
}
]
},
{
"product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:07.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC CP 1626",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1 Update 14"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V15",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.4.0"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.8.1"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC S7-PLCSIM Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC OA",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.16 P013"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10929",
"datePublished": "2019-08-13T18:55:57.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2019-10929",
"date": "2026-05-29",
"epss": "0.00139",
"percentile": "0.33683"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-10929\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-08-13T19:15:14.860\",\"lastModified\":\"2024-11-21T04:20:10.487\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC CP 1626 (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS) (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) (Todas las versiones anteriores a V20. 8), SIMATIC HMI Panel (incl. variantes SIPLUS) (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones anteriores a V4.4.0), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones anteriores a V2.8.1), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a V20.8), SIMATIC S7-PLCSIM Advanced (Todas las versiones anteriores a V3.0), SIMATIC STEP 7 (TIA Portal) (Todas las versiones anteriores a V16), SIMATIC WinCC (TIA Portal) (Todas las versiones anteriores a V16), SIMATIC WinCC OA (Todas las versiones anteriores a V3. 16 P013), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a V16), SIMATIC WinCC Runtime Professional (Todas las versiones anteriores a V16), TIM 1531 IRC (incl. variantes de SIPLUS NET) (Todas las versiones anteriores a V2.1). Los dispositivos afectados contienen una vulnerabilidad de elusi\u00f3n de la protecci\u00f3n de mensajes debido a ciertas propiedades en el c\u00e1lculo utilizado para la protecci\u00f3n de la integridad. Esto podr\u00eda permitir a un atacante en posici\u00f3n de Man-in-the-Middle modificar el tr\u00e1fico de red enviado por el puerto 102/tcp a los dispositivos afectados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-327\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FFA8109D-F938-4FE3-9885-831D2D0FE058\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8AED132-C4CF-4C2E-B826-DFAE745256FD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C59DF55E-2F4F-4BF1-B02F-05916BC863D4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"30E3491F-8F4A-4C7D-960D-073AA41DB4D6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"621AC3EC-6DA3-4AA6-9100-0407EC8370E6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3871C0C9-C65E-4E0B-9CA8-75E60066297F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"9F22D58C-444F-4179-B84F-24D57F4971EB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07849777-92E7-41D2-9128-F8D20DE15391\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"985A67F3-9799-4D30-B049-619456280DA4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FE17584A-BF7A-48B8-A9CB-477663766C63\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"6A5E0374-939D-4C5E-B721-5AD8A3329387\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC4698CF-F935-4707-BA91-7E3650C7956C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0\",\"matchCriteriaId\":\"FF7EA085-2297-4BA0-96AB-2A2EBE0BEFAF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"232279DE-CF1C-4A3C-886D-B4CE3F104F09\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF4F6EA7-68BD-4A9D-8DDC-1D802EA7905B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BE0BA68C-EB57-49CE-94A8-E7905AB79824\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33F882B8-EEDF-489E-9933-37EFC0AAC356\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"822894D4-96D5-4BDC-A698-D31262BCF422\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C9E8D52B-CDB3-4E26-A0C4-592CCBFBB827\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2E24A4C-AC13-4382-BDF6-E13878FED4DC\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"744B5953-511F-42CA-80A0-DBE36A6AA144\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_s7-1500:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA1684C0-4B7C-44A0-9F16-5F8121654397\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2C9A3749-B092-4F92-8140-55F10A03A5DB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"E6D968D9-2A64-4E1C-824F-6508AEC6789D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16\",\"matchCriteriaId\":\"F96AD4B7-105A-4D60-9026-E5C6389F3C73\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_open_architecture:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.15\",\"matchCriteriaId\":\"4C3580BA-45F0-4A01-925F-D56B0BA058F7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"84D652E6-23F7-4EB6-AE66-69662E191559\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:patch_12:*:*:*:*:*:*\",\"matchCriteriaId\":\"1F0B76B7-FCB4-4831-BD00-AF29FD4606B2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*\",\"matchCriteriaId\":\"29B1F502-8A3A-4C07-90D2-CE5EB06CB573\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*\",\"matchCriteriaId\":\"0384FFF2-F577-4FFC-8A84-5682771D1BC1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2DA2E87-7B96-4B6B-90F9-C22B138B441B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"581EA284-EDD6-4EA5-96B2-67904D1D9DC7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_tim_1531_irc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.1\",\"matchCriteriaId\":\"95DEFB00-96A2-460F-8B59-A288FD154FDC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_tim_1531_irc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AEFDF765-44F4-45CB-8A28-FD7D355310DA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_panel_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE91BB69-3E42-4110-B49B-D53DB894E140\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_panel:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"35CA808F-891D-4E10-A87A-68440D0BE0CB\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-344-04\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-344-04\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
CERTFR-2019-AVI-385
Vulnerability from certfr_avis - Published: 2019-08-13 - Updated: 2019-08-13
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SCALANCE X-200 | ||
| Siemens | N/A | SINAMICS GL150 versions V4.7 et V4.8 antérieures à V4.8 SP2 HF9 | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller | ||
| Siemens | N/A | SIMATIC S7-1500 CPU family | ||
| Siemens | N/A | SINAMICS GM150 versions V4.7 et V4.8 antérieures à V4.8 SP2 HF9 | ||
| Siemens | N/A | SINAMICS SL150 V4.8 | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU1515SP PC | ||
| Siemens | N/A | SCALANCE X-200IRT | ||
| Siemens | N/A | SINAMICS GH150 versions V4.7 et V4.8 antérieures à V4.8 SP2 HF9 | ||
| Siemens | N/A | SINAMICS SM150 V4.8 | ||
| Siemens | N/A | SINAMICS SL150 V4.7 | ||
| Siemens | N/A | SCALANCE SC-600 versions antérieures à V2.0.1 | ||
| Siemens | N/A | SIMATIC S7-PLCSIM Advanced | ||
| Siemens | N/A | SINAMICS SM120 V4.8 | ||
| Siemens | N/A | SCALANCE XB-200, XC-200, XF-200BA, XP-200 et XR-300WG version V4.1 | ||
| Siemens | N/A | SCALANCE X-200RNA | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU1515SP PC2 | ||
| Siemens | N/A | SIMATIC S7-1200 CPU family versions supérieures à V4.0 | ||
| Siemens | N/A | SINAMICS SM120 V4.7 |
| Title | Publication Time | Tags | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SCALANCE X-200",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS GL150 versions V4.7 et V4.8 ant\u00e9rieures \u00e0 V4.8 SP2 HF9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU family",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS GM150 versions V4.7 et V4.8 ant\u00e9rieures \u00e0 V4.8 SP2 HF9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS SL150 V4.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU1515SP PC",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200IRT",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS GH150 versions V4.7 et V4.8 ant\u00e9rieures \u00e0 V4.8 SP2 HF9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS SM150 V4.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS SL150 V4.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC-600 versions ant\u00e9rieures \u00e0 V2.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-PLCSIM Advanced",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS SM120 V4.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB-200, XC-200, XF-200BA, XP-200 et XR-300WG version V4.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200RNA",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU1515SP PC2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1200 CPU family versions sup\u00e9rieures \u00e0 V4.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS SM120 V4.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-10927",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10927"
},
{
"name": "CVE-2019-6568",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6568"
},
{
"name": "CVE-2019-10943",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10943"
},
{
"name": "CVE-2019-10929",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10929"
},
{
"name": "CVE-2019-10942",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10942"
},
{
"name": "CVE-2019-10928",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10928"
}
],
"initial_release_date": "2019-08-13T00:00:00",
"last_revision_date": "2019-08-13T00:00:00",
"links": [],
"reference": "CERTFR-2019-AVI-385",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-08-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-671286 du 13 ao\u00fbt 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-671286.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-100232 du 13 ao\u00fbt 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-100232.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-232418 du 13 ao\u00fbt 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-530931 du 13 ao\u00fbt 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
}
]
}
CERTFR-2019-AVI-615
Vulnerability from certfr_avis - Published: 2019-12-10 - Updated: 2019-12-10
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SPPA-T3000 MS3000 Migration Server | ||
| Siemens | N/A | SiNVR 3 Central Control Server (CCS) | ||
| Siemens | N/A | SIMATIC S7-1200 CPU | ||
| Siemens | N/A | RUGGEDCOM ROS RSG9xx R/C | ||
| Siemens | N/A | RUGGEDCOM ROS RMC8388 | ||
| Siemens | N/A | EN100 Ethernet module Modbus TCP | ||
| Siemens | N/A | SIMATIC WinCC OA | ||
| Siemens | N/A | SIMATIC CP 1626 | ||
| Siemens | N/A | SCALANCE W700 versions antérieures à V6.4 | ||
| Siemens | N/A | SIMATIC NET PC | ||
| Siemens | N/A | SIMATIC WinCC Runtime Professional | ||
| Siemens | N/A | EN100 Ethernet module IEC 61850 versions antérieures à V4.37 | ||
| Siemens | N/A | SPPA-T3000 Application Server versions antérieures à Service Pack R8.2 SP1 | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced | ||
| Siemens | N/A | RUGGEDCOM ROS RSL910 | ||
| Siemens | N/A | SIMATIC WinCC (TIA Portal) versions antérieures à V16 | ||
| Siemens | N/A | Famille de commutateurs SCALANCE X-200IRT et les variantes SIPLUSNET versions antérieures à V5.4.2 | ||
| Siemens | N/A | SIMATIC S7-200 SMART CPU | ||
| Siemens | N/A | SIMATIC WinCC OA versions antérieures à 3.16 patch version 13 | ||
| Siemens | N/A | SiNVR 3 Video Server | ||
| Siemens | N/A | EN100 Ethernet module DNP3 | ||
| Siemens | N/A | SCALANCE W1700 versions antérieures à V1.1 | ||
| Siemens | N/A | RUGGEDCOM ROS RSG2488 | ||
| Siemens | N/A | EN100 Ethernet module PROFINET IO | ||
| Siemens | N/A | EN100 Ethernet module IEC104 | ||
| Siemens | N/A | RUGGEDCOM ROS RSG920P | ||
| Siemens | N/A | TIM 1531 IRC | ||
| Siemens | N/A | XHQ versions antérieures à V6.0.0.2 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) versions antérieures à V16 | ||
| Siemens | N/A | RUGGEDCOM ROS RST2228 | ||
| Siemens | N/A | SIMATIC HMI Panel | ||
| Siemens | N/A | Famille de commutateurs SCALANCE X-200 et les variantes SIPLUSNET versions antérieures à V5.2.4 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SPPA-T3000 MS3000 Migration Server",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiNVR 3 Central Control Server (CCS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1200 CPU",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RSG9xx R/C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RMC8388",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module Modbus TCP",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1626",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W700 versions ant\u00e9rieures \u00e0 V6.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Professional",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module IEC 61850 versions ant\u00e9rieures \u00e0 V4.37",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SPPA-T3000 Application Server versions ant\u00e9rieures \u00e0 Service Pack R8.2 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RSL910",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC (TIA Portal) versions ant\u00e9rieures \u00e0 V16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Famille de commutateurs SCALANCE X-200IRT et les variantes SIPLUSNET versions ant\u00e9rieures \u00e0 V5.4.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-200 SMART CPU",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA versions ant\u00e9rieures \u00e0 3.16 patch version 13",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiNVR 3 Video Server",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module DNP3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1700 versions ant\u00e9rieures \u00e0 V1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RSG2488",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module PROFINET IO",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module IEC104",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RSG920P",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 1531 IRC",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "XHQ versions ant\u00e9rieures \u00e0 V6.0.0.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) versions ant\u00e9rieures \u00e0 V16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS RST2228",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Panel",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Famille de commutateurs SCALANCE X-200 et les variantes SIPLUSNET versions ant\u00e9rieures \u00e0 V5.2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-13944",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13944"
},
{
"name": "CVE-2019-18339",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18339"
},
{
"name": "CVE-2019-18341",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18341"
},
{
"name": "CVE-2019-18332",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18332"
},
{
"name": "CVE-2019-18335",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18335"
},
{
"name": "CVE-2019-18338",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18338"
},
{
"name": "CVE-2018-14526",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-14526"
},
{
"name": "CVE-2019-18319",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18319"
},
{
"name": "CVE-2019-18331",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18331"
},
{
"name": "CVE-2019-18312",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18312"
},
{
"name": "CVE-2019-18320",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18320"
},
{
"name": "CVE-2019-18322",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18322"
},
{
"name": "CVE-2019-18283",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18283"
},
{
"name": "CVE-2019-18303",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18303"
},
{
"name": "CVE-2019-18302",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18302"
},
{
"name": "CVE-2019-18311",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18311"
},
{
"name": "CVE-2019-18290",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18290"
},
{
"name": "CVE-2019-18292",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18292"
},
{
"name": "CVE-2019-18309",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18309"
},
{
"name": "CVE-2019-18291",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18291"
},
{
"name": "CVE-2019-18304",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18304"
},
{
"name": "CVE-2019-18326",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18326"
},
{
"name": "CVE-2019-18305",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18305"
},
{
"name": "CVE-2019-18318",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18318"
},
{
"name": "CVE-2013-3634",
"url": "https://www.cve.org/CVERecord?id=CVE-2013-3634"
},
{
"name": "CVE-2019-18334",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18334"
},
{
"name": "CVE-2019-18299",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18299"
},
{
"name": "CVE-2019-13932",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13932"
},
{
"name": "CVE-2019-18316",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18316"
},
{
"name": "CVE-2019-18329",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18329"
},
{
"name": "CVE-2019-10929",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10929"
},
{
"name": "CVE-2019-13931",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13931"
},
{
"name": "CVE-2019-18333",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18333"
},
{
"name": "CVE-2019-18300",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18300"
},
{
"name": "CVE-2019-18301",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18301"
},
{
"name": "CVE-2019-18328",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18328"
},
{
"name": "CVE-2019-18321",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18321"
},
{
"name": "CVE-2019-13947",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13947"
},
{
"name": "CVE-2019-18317",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18317"
},
{
"name": "CVE-2019-18294",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18294"
},
{
"name": "CVE-2019-13943",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13943"
},
{
"name": "CVE-2019-18330",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18330"
},
{
"name": "CVE-2019-18314",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18314"
},
{
"name": "CVE-2019-18307",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18307"
},
{
"name": "CVE-2019-13945",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13945"
},
{
"name": "CVE-2019-18308",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18308"
},
{
"name": "CVE-2013-3633",
"url": "https://www.cve.org/CVERecord?id=CVE-2013-3633"
},
{
"name": "CVE-2019-18306",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18306"
},
{
"name": "CVE-2019-18340",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18340"
},
{
"name": "CVE-2019-18342",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18342"
},
{
"name": "CVE-2019-18325",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18325"
},
{
"name": "CVE-2018-4832",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-4832"
},
{
"name": "CVE-2019-18310",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18310"
},
{
"name": "CVE-2019-13103",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13103"
},
{
"name": "CVE-2019-13930",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13930"
},
{
"name": "CVE-2019-18337",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18337"
},
{
"name": "CVE-2019-18323",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18323"
},
{
"name": "CVE-2019-18327",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18327"
},
{
"name": "CVE-2018-18440",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-18440"
},
{
"name": "CVE-2019-18315",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18315"
},
{
"name": "CVE-2019-18298",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18298"
},
{
"name": "CVE-2019-13942",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13942"
},
{
"name": "CVE-2019-18313",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18313"
},
{
"name": "CVE-2019-18324",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18324"
}
],
"initial_release_date": "2019-12-10T00:00:00",
"last_revision_date": "2019-12-10T00:00:00",
"links": [],
"reference": "CERTFR-2019-AVI-615",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-12-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-451445 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-418979 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-170686 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170686.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-344983 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344983.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-761617 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-618620 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-618620.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-525454 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-525454.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-686531 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-273799 du 10 d\u00e9cembre 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
}
]
}
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf
| Name | ['Siemens SIMATIC S7-1500 Software Controller', 'Siemens SIMATIC S7-1500 CPU family', 'Siemens SIMATIC S7-PLCSIM Advanced', 'SIEMENS SIMATIC S7-1200 CPU family >=V4.0', 'SIEMENS SIMATIC ET 200SP Open Controller CPU1515SP PC', 'SIEMENS SIMATIC ET 200SP Open Controller CPU1515SP PC2'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2019-10929"
}
},
"description": "Simatic S7-1200 CPU\u548cSimatic S7-1500 CPU\u7cfb\u5217\u7684\u4ea7\u54c1\u662f\u5de5\u4e1a\u73af\u5883\uff08\u5982\u5236\u9020\u4e1a\u3001\u98df\u54c1\u548c\u996e\u6599\u4e1a\u4ee5\u53ca\u5316\u5de5\u884c\u4e1a\uff09\u4e2d\u8fdb\u884c\u79bb\u6563\u548c\u8fde\u7eed\u63a7\u5236\u3002\n\nSIMATICS7-1200 and SIMATICS7-1500CPU families\u5b58\u5728\u4e2d\u95f4\u4eba\u653b\u51fb\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u4fee\u6539\u5728\u7aef\u53e3102/TCP\u4e0a\u4ea4\u6362\u7684\u7f51\u7edc\u6d41\u91cf\uff0c\u6267\u884c\u4e2d\u95f4\u4f4d\u7f6e\u7684\u4eba\u653b\u51fb\u3002",
"discovererName": "Eli Biham, Sara Bitan, Aviad Carmel, and Alon Dankner from Faculty of Computer Science, TechnionHaifa",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2019-27647",
"openTime": "2019-08-14",
"patchDescription": "Simatic S7-1200 CPU\u548cSimatic S7-1500 CPU\u7cfb\u5217\u7684\u4ea7\u54c1\u662f\u5de5\u4e1a\u73af\u5883\uff08\u5982\u5236\u9020\u4e1a\u3001\u98df\u54c1\u548c\u996e\u6599\u4e1a\u4ee5\u53ca\u5316\u5de5\u884c\u4e1a\uff09\u4e2d\u8fdb\u884c\u79bb\u6563\u548c\u8fde\u7eed\u63a7\u5236\u3002\r\n\r\nSIMATICS7-1200 and SIMATICS7-1500CPU families\u5b58\u5728\u4e2d\u95f4\u4eba\u653b\u51fb\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u4fee\u6539\u5728\u7aef\u53e3102/TCP\u4e0a\u4ea4\u6362\u7684\u7f51\u7edc\u6d41\u91cf\uff0c\u6267\u884c\u4e2d\u95f4\u4f4d\u7f6e\u7684\u4eba\u653b\u51fb\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "SIMATICS7-1200 and SIMATICS7-1500CPU families\u4e2d\u95f4\u4eba\u653b\u51fb\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens SIMATIC S7-1500 Software Controller",
"Siemens SIMATIC S7-1500 CPU family",
"Siemens SIMATIC S7-PLCSIM Advanced",
"SIEMENS SIMATIC S7-1200 CPU family \u003e=V4.0",
"SIEMENS SIMATIC ET 200SP Open Controller CPU1515SP PC",
"SIEMENS SIMATIC ET 200SP Open Controller CPU1515SP PC2"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
"serverity": "\u4f4e",
"submitTime": "2019-08-14",
"title": "SIMATICS7-1200 and SIMATICS7-1500CPU families\u4e2d\u95f4\u4eba\u653b\u51fb\u6f0f\u6d1e"
}
FKIE_CVE-2019-10929
Vulnerability from fkie_nvd - Published: 2019-08-13 19:15 - Updated: 2024-11-21 04:20| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf | Vendor Advisory | |
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf | Vendor Advisory | |
| productcert@siemens.com | https://www.us-cert.gov/ics/advisories/icsa-19-344-04 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-344-04 | Third Party Advisory, US Government Resource |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FFA8109D-F938-4FE3-9885-831D2D0FE058",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E8AED132-C4CF-4C2E-B826-DFAE745256FD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C59DF55E-2F4F-4BF1-B02F-05916BC863D4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "621AC3EC-6DA3-4AA6-9100-0407EC8370E6",
"versionEndIncluding": "4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9F22D58C-444F-4179-B84F-24D57F4971EB",
"versionEndIncluding": "4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "985A67F3-9799-4D30-B049-619456280DA4",
"versionEndIncluding": "4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6A5E0374-939D-4C5E-B721-5AD8A3329387",
"versionEndIncluding": "4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FF7EA085-2297-4BA0-96AB-2A2EBE0BEFAF",
"versionEndIncluding": "4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DF4F6EA7-68BD-4A9D-8DDC-1D802EA7905B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "33F882B8-EEDF-489E-9933-37EFC0AAC356",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C9E8D52B-CDB3-4E26-A0C4-592CCBFBB827",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "744B5953-511F-42CA-80A0-DBE36A6AA144",
"versionEndExcluding": "16",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-1500:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FA1684C0-4B7C-44A0-9F16-5F8121654397",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C9A3749-B092-4F92-8140-55F10A03A5DB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E6D968D9-2A64-4E1C-824F-6508AEC6789D",
"versionEndExcluding": "16",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F96AD4B7-105A-4D60-9026-E5C6389F3C73",
"versionEndExcluding": "16",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4C3580BA-45F0-4A01-925F-D56B0BA058F7",
"versionEndIncluding": "3.15",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:-:*:*:*:*:*:*",
"matchCriteriaId": "84D652E6-23F7-4EB6-AE66-69662E191559",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:patch_12:*:*:*:*:*:*",
"matchCriteriaId": "1F0B76B7-FCB4-4831-BD00-AF29FD4606B2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*",
"matchCriteriaId": "29B1F502-8A3A-4C07-90D2-CE5EB06CB573",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*",
"matchCriteriaId": "0384FFF2-F577-4FFC-8A84-5682771D1BC1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D2DA2E87-7B96-4B6B-90F9-C22B138B441B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*",
"matchCriteriaId": "581EA284-EDD6-4EA5-96B2-67904D1D9DC7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "95DEFB00-96A2-460F-8B59-A288FD154FDC",
"versionEndExcluding": "2.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_tim_1531_irc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AEFDF765-44F4-45CB-8A28-FD7D355310DA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_panel_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EE91BB69-3E42-4110-B49B-D53DB894E140",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_panel:-:*:*:*:*:*:*:*",
"matchCriteriaId": "35CA808F-891D-4E10-A87A-68440D0BE0CB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC CP 1626 (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS) (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) (Todas las versiones anteriores a V20. 8), SIMATIC HMI Panel (incl. variantes SIPLUS) (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones anteriores a V4.4.0), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones anteriores a V2.8.1), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a V20.8), SIMATIC S7-PLCSIM Advanced (Todas las versiones anteriores a V3.0), SIMATIC STEP 7 (TIA Portal) (Todas las versiones anteriores a V16), SIMATIC WinCC (TIA Portal) (Todas las versiones anteriores a V16), SIMATIC WinCC OA (Todas las versiones anteriores a V3. 16 P013), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a V16), SIMATIC WinCC Runtime Professional (Todas las versiones anteriores a V16), TIM 1531 IRC (incl. variantes de SIPLUS NET) (Todas las versiones anteriores a V2.1). Los dispositivos afectados contienen una vulnerabilidad de elusi\u00f3n de la protecci\u00f3n de mensajes debido a ciertas propiedades en el c\u00e1lculo utilizado para la protecci\u00f3n de la integridad. Esto podr\u00eda permitir a un atacante en posici\u00f3n de Man-in-the-Middle modificar el tr\u00e1fico de red enviado por el puerto 102/tcp a los dispositivos afectados"
}
],
"id": "CVE-2019-10929",
"lastModified": "2024-11-21T04:20:10.487",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-08-13T19:15:14.860",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-327"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
GHSA-77J2-3682-MQMJ
Vulnerability from github – Published: 2022-05-24 16:53 – Updated: 2022-05-24 16:53A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (All versions), SIMATIC S7-1200 CPU family (All versions >= V4.0), SIMATIC S7-1500 CPU family (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-PLCSIM Advanced (All versions). An attacker in a Man-in-the-Middle position could potentially modify network traffic exchanged on port 102/tcp, due to certain properties in the calculation used for integrity protection. In order to exploit the vulnerability, an attacker must be able to perform a Man-in-the-Middle attack. The vulnerability could impact the integrity of the communication. No public exploitation of the vulnerability was known at the time of advisory publication.
{
"affected": [],
"aliases": [
"CVE-2019-10929"
],
"database_specific": {
"cwe_ids": [
"CWE-327"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2019-08-13T19:15:00Z",
"severity": "MODERATE"
},
"details": "A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (All versions), SIMATIC S7-1200 CPU family (All versions \u003e= V4.0), SIMATIC S7-1500 CPU family (All versions), SIMATIC S7-1500 Software Controller (All versions), SIMATIC S7-PLCSIM Advanced (All versions). An attacker in a Man-in-the-Middle position could potentially modify network traffic exchanged on port 102/tcp, due to certain properties in the calculation used for integrity protection. In order to exploit the vulnerability, an attacker must be able to perform a Man-in-the-Middle attack. The vulnerability could impact the integrity of the communication. No public exploitation of the vulnerability was known at the time of advisory publication.",
"id": "GHSA-77j2-3682-mqmj",
"modified": "2022-05-24T16:53:14Z",
"published": "2022-05-24T16:53:14Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-10929"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"type": "WEB",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"type": "CVSS_V3"
}
]
}
GSD-2019-10929
Vulnerability from gsd - Updated: 2023-12-13 01:23{
"GSD": {
"alias": "CVE-2019-10929",
"description": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c= 20.8), SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC (All versions), SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC2 (All versions), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software (All versions), SIMATIC S7 PLCSIM Advanced (All versions \u003c= V3.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c= V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), excluding CPU 1518 MFP (and related SIPLUS variant) (All versions \u003c= V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), excluding CPU 1518-4 PN/DP and CPU 1518 MFP (and related SIPLUS variant) (All versions \u003c= V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c= V20.8), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c= 3.15), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional (All versions), TIM 1531 IRC (incl. SIPLUS variant) (All versions). An attacker in a Man-in-the-Middle position could potentially modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families, due to certain properties in the calculation used for integrity protection. In order to exploit the vulnerability, an attacker must be able to perform a Man-in-the-Middle attack. The vulnerability could impact the integrity of the communication. No public exploitation of the vulnerability was known at the time of advisory publication.",
"id": "GSD-2019-10929"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2019-10929"
],
"details": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.",
"id": "GSD-2019-10929",
"modified": "2023-12-13T01:23:59.945508Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC CP 1626",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1 Update 14"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V15",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.4.0"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.8.1"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V20.8"
}
]
}
},
{
"product_name": "SIMATIC S7-PLCSIM Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.0"
}
]
}
},
{
"product_name": "SIMATIC STEP 7 (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC OA",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.16 P013"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16"
}
]
}
},
{
"product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_s7-1500:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "16",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "16",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:patch_12:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "16",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.15",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_tim_1531_irc:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_panel_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_panel:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10929"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-327"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 3.6
}
},
"lastModifiedDate": "2022-08-10T20:15Z",
"publishedDate": "2019-08-13T19:15Z"
}
}
}
ICSA-19-344-04
Vulnerability from csaf_cisa - Published: 2019-12-10 00:00 - Updated: 2025-05-06 06:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC CP 1626
Siemens / SIMATIC CP 1626
|
6GK1162-6AA01
|
vers:all/* |
No Fix Planned
|
|
SIMATIC HMI Panel (incl. SIPLUS variants)
Siemens / SIMATIC HMI Panel (incl. SIPLUS variants)
|
vers:all/* |
No Fix Planned
|
|
|
SIMATIC NET PC Software V14
Siemens / SIMATIC NET PC Software V14
|
<V14_SP1_Update_14 |
Vendor Fix
fix
|
|
|
SIMATIC NET PC Software V15
Siemens / SIMATIC NET PC Software V15
|
vers:all/* |
No Fix Planned
|
|
|
SIMATIC STEP 7 (TIA Portal)
Siemens / SIMATIC STEP 7 (TIA Portal)
|
<V16 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC (TIA Portal)
Siemens / SIMATIC WinCC (TIA Portal)
|
<V16 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC OA
Siemens / SIMATIC WinCC OA
|
<V3.16_P013 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
<V16 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC Runtime Professional
Siemens / SIMATIC WinCC Runtime Professional
|
<V16 |
Vendor Fix
fix
|
|
|
TIM 1531 IRC (incl. SIPLUS NET variants)
Siemens / TIM 1531 IRC (incl. SIPLUS NET variants)
|
<V2.1 |
Vendor Fix
fix
|
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
},
{
"names": [
"Eli Biham",
"Sara Bitan",
"Aviad Carmel",
"Alon Dankner"
],
"organization": "Faculty of Computer Science, Technion Haifa",
"summary": "reporting the vulnerabilities"
},
{
"names": [
"Avishai Wool",
"Uriel Malin"
],
"organization": "School of Electrical Engineering, Tel-Aviv University",
"summary": "reporting the vulnerabilities"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "A message integrity protection bypass vulnerability has been identified in several SIMATIC products. The vulnerability could allow an attacker in a Man-in-the-Middle position to modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families.\n\nSiemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-273799.json"
},
{
"category": "self",
"summary": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-273799.txt"
},
{
"category": "self",
"summary": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-344-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-344-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-344-04 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-344-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC Products (Update C)",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-344-04",
"initial_release_date": "2019-12-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-12-10T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2020-02-11T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added solution for TIM 1531 IRC and SIMATIC NET PC Software"
},
{
"date": "2020-03-10T00:00:00.000000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added links for WinCC Runtime"
},
{
"date": "2022-04-12T00:00:00.000000Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added solution for SIMATIC NET PC Software V14 and clarified affected versions; Clarified no remediation planned"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "5",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "5"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC CP 1626",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"6GK1162-6AA01"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1626"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI Panel (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV14_SP1_Update_14",
"product": {
"name": "SIMATIC NET PC Software V14",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SIMATIC NET PC Software V14"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC NET PC Software V15",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "SIMATIC NET PC Software V15"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16",
"product": {
"name": "SIMATIC STEP 7 (TIA Portal)",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "SIMATIC STEP 7 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16",
"product": {
"name": "SIMATIC WinCC (TIA Portal)",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.16_P013",
"product": {
"name": "SIMATIC WinCC OA",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC OA"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16",
"product": {
"name": "SIMATIC WinCC Runtime Advanced",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Advanced"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16",
"product": {
"name": "SIMATIC WinCC Runtime Professional",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV2.1",
"product": {
"name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"product_id": "CSAFPID-0010"
}
}
],
"category": "product_name",
"name": "TIM 1531 IRC (incl. SIPLUS NET variants)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-10929",
"cwe": {
"id": "CWE-327",
"name": "Use of a Broken or Risky Cryptographic Algorithm"
},
"notes": [
{
"category": "summary",
"text": "Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection.\n\nThis could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010"
]
},
"references": [
{
"summary": "CVE-2019-10929 - SIMATIC NET PC Software V14",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109807351/"
},
{
"summary": "CVE-2019-10929 - SIMATIC STEP 7 (TIA Portal)",
"url": "https://support.industry.siemens.com/cs/document/109772803/"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC (TIA Portal)",
"url": "https://support.industry.siemens.com/cs/document/109772803/"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC OA",
"url": "https://www.winccoa.com/downloads/category/versions-patches.html"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/document/109771219/"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC Runtime Professional",
"url": "https://support.industry.siemens.com/cs/document/109771219/"
},
{
"summary": "CVE-2019-10929 - TIM 1531 IRC (incl. SIPLUS NET variants)",
"url": "https://support.industry.siemens.com/cs/document/109774204/"
},
{
"summary": "CVE-2019-10929 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-10929.json"
}
],
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0004"
]
},
{
"category": "vendor_fix",
"details": "Update to V14 SP1 Update 14 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109807351/"
},
{
"category": "vendor_fix",
"details": "Update to version V16",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-0006"
],
"url": "https://support.industry.siemens.com/cs/document/109772803/"
},
{
"category": "vendor_fix",
"details": "Update to V3.16 P013 or later version",
"product_ids": [
"CSAFPID-0007"
],
"url": "https://www.winccoa.com/downloads/category/versions-patches.html"
},
{
"category": "vendor_fix",
"details": "Update to version V16",
"product_ids": [
"CSAFPID-0008",
"CSAFPID-0009"
],
"url": "https://support.industry.siemens.com/cs/document/109771219/"
},
{
"category": "vendor_fix",
"details": "Update to V2.1",
"product_ids": [
"CSAFPID-0010"
],
"url": "https://support.industry.siemens.com/cs/document/109774204/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-0010"
]
}
],
"title": "CVE-2019-10929"
}
]
}
ICSA-19-344-06
Vulnerability from csaf_cisa - Published: 2019-12-10 00:00 - Updated: 2020-03-10 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC Drive Controller family: All versions (only affected by CVE-2019-10943)
Siemens / SIMATIC Drive Controller family
|
* (only affected by CVE-2019-10943) |
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): All versions prior to V2.8.1
Siemens / SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
|
< 2.8.1 |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-PLCSIM Advanced: All versions prior to V3.0
Siemens / SIMATIC S7-PLCSIM Advanced
|
< 3.0 |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1500 Software Controller: All versions prior to V20.8
Siemens / SIMATIC S7-1500 Software Controller
|
< 20.8 |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1200 CPU family (incl. SIPLUS variants): All versions prior to V4.4.0
Siemens / SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
|
< 4.4.0 |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC: All versions
Siemens / SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC
|
vers:all/* |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): Versions 2.8.1 and later (only affected by CVE-2019-10943)
Siemens / SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
|
>= 2.8.1 (only affected by CVE-2019-10943) |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): Versions 20.8 and later (only affected by CVE-2019-10943)
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
|
>= 20.8 (only affected by CVE-2019-10943) |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants): All versions
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)
|
vers:all/* |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-PLCSIM Advanced: Versions 3.0 and later (only affected by CVE-2019-10943)
Siemens / SIMATIC S7-PLCSIM Advanced
|
>= 3.0 (only affected by CVE-2019-10943) |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1200 CPU family (incl. SIPLUS variants): Versions 4.4.0 and later (only affected by CVE-2019-10943)
Siemens / SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
|
>= 4.4.0 (only affected by CVE-2019-10943) |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): All versions prior to V20.8
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
|
< 20.8 |
Vendor Fix
fix
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1500 Software Controller: Versions 20.8 and later (only affected by CVE-2019-10943)
Siemens / SIMATIC S7-1500 Software Controller
|
>= 20.8 (only affected by CVE-2019-10943) |
Vendor Fix
fix
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC Drive Controller family: All versions (only affected by CVE-2019-10943)
Siemens / SIMATIC Drive Controller family
|
* (only affected by CVE-2019-10943) |
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): All versions prior to V2.8.1
Siemens / SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
|
< 2.8.1 |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-PLCSIM Advanced: All versions prior to V3.0
Siemens / SIMATIC S7-PLCSIM Advanced
|
< 3.0 |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1500 Software Controller: All versions prior to V20.8
Siemens / SIMATIC S7-1500 Software Controller
|
< 20.8 |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1200 CPU family (incl. SIPLUS variants): All versions prior to V4.4.0
Siemens / SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
|
< 4.4.0 |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC: All versions
Siemens / SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC
|
vers:all/* |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): Versions 2.8.1 and later (only affected by CVE-2019-10943)
Siemens / SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
|
>= 2.8.1 (only affected by CVE-2019-10943) |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): Versions 20.8 and later (only affected by CVE-2019-10943)
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
|
>= 20.8 (only affected by CVE-2019-10943) |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants): All versions
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)
|
vers:all/* |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-PLCSIM Advanced: Versions 3.0 and later (only affected by CVE-2019-10943)
Siemens / SIMATIC S7-PLCSIM Advanced
|
>= 3.0 (only affected by CVE-2019-10943) |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1200 CPU family (incl. SIPLUS variants): Versions 4.4.0 and later (only affected by CVE-2019-10943)
Siemens / SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
|
>= 4.4.0 (only affected by CVE-2019-10943) |
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): All versions prior to V20.8
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
|
< 20.8 |
Vendor Fix
fix
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
|
|
SIMATIC S7-1500 Software Controller: Versions 20.8 and later (only affected by CVE-2019-10943)
Siemens / SIMATIC S7-1500 Software Controller
|
>= 20.8 (only affected by CVE-2019-10943) |
Vendor Fix
fix
Vendor Fix
fix
Mitigation
Mitigation
fix
Mitigation
Mitigation
Mitigation
fix
|
{
"document": {
"acknowledgments": [
{
"names": [
"Eli Biham",
"Sara Bitan",
"Aviad Carmel",
"Alon Dankner"
],
"organization": "Faculty of Computer Science, Technion Haifa",
"summary": "reporting these vulnerabilities to Siemens"
},
{
"names": [
"Uriel Malin",
"Avishai Wool"
],
"organization": "School of Electrical Engineering, Tel-Aviv University",
"summary": "reporting these vulnerabilities to Siemens"
},
{
"names": [
"Artem Zinenko"
],
"organization": "Kaspersky",
"summary": "reporting these vulnerabilities to Siemens"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities may allow an attacker to modify network traffic or impact the perceived integrity of the user program stored on the CPU.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-19-344-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-344-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-344-06 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-344-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update B)",
"tracking": {
"current_release_date": "2020-03-10T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-344-06",
"initial_release_date": "2019-12-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-12-10T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-19-344-06 Siemens SIMATIC S7-1200 and SIMATIC S7-1500 CPU Families"
},
{
"date": "2020-03-10T00:00:00.000000Z",
"legacy_version": "A",
"number": "2",
"summary": "ICSA-19-344-06 Siemens SIMATIC S7-1200 and S7-1500 CPU families (Update A)"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "* (only affected by CVE-2019-10943)",
"product": {
"name": "SIMATIC Drive Controller family: All versions (only affected by CVE-2019-10943)",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC Drive Controller family"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 2.8.1",
"product": {
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): All versions prior to V2.8.1",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 3.0",
"product": {
"name": "SIMATIC S7-PLCSIM Advanced: All versions prior to V3.0",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-PLCSIM Advanced"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 20.8",
"product": {
"name": "SIMATIC S7-1500 Software Controller: All versions prior to V20.8",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 Software Controller"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 4.4.0",
"product": {
"name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants): All versions prior to V4.4.0",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version",
"name": "vers:all/*",
"product": {
"name": "SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC: All versions",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "SIMATIC ET200SP (incl. SIPLUS variants) Open Controller CPU 1515SP PC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= 2.8.1 (only affected by CVE-2019-10943)",
"product": {
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants): Versions 2.8.1 and later (only affected by CVE-2019-10943)",
"product_id": "CSAFPID-0007"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= 20.8 (only affected by CVE-2019-10943)",
"product": {
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): Versions 20.8 and later (only affected by CVE-2019-10943)",
"product_id": "CSAFPID-0008"
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version",
"name": "vers:all/*",
"product": {
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants): All versions",
"product_id": "CSAFPID-0009"
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= 3.0 (only affected by CVE-2019-10943)",
"product": {
"name": "SIMATIC S7-PLCSIM Advanced: Versions 3.0 and later (only affected by CVE-2019-10943)",
"product_id": "CSAFPID-00010"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-PLCSIM Advanced"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= 4.4.0 (only affected by CVE-2019-10943)",
"product": {
"name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants): Versions 4.4.0 and later (only affected by CVE-2019-10943)",
"product_id": "CSAFPID-00011"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 20.8",
"product": {
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants): All versions prior to V20.8",
"product_id": "CSAFPID-00012"
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= 20.8 (only affected by CVE-2019-10943)",
"product": {
"name": "SIMATIC S7-1500 Software Controller: Versions 20.8 and later (only affected by CVE-2019-10943)",
"product_id": "CSAFPID-00013"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 Software Controller"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-10929",
"cwe": {
"id": "CWE-327",
"name": "Use of a Broken or Risky Cryptographic Algorithm"
},
"notes": [
{
"category": "summary",
"text": "An attacker in a man-in-the-middle position could modify network traffic exchanged on Port 102/TCP, due to certain properties in the calculation used for integrity protection. CVE-2019-10929 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10929"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "SIMATIC S7 PLCSIM Advanced: Update to v3.0",
"product_ids": [
"CSAFPID-0003",
"CSAFPID-00010"
],
"url": "https://support.industry.siemens.com/cs/document/109772889/"
},
{
"category": "vendor_fix",
"details": "SIMATIC S7-1200 CPU family: Update to v4.4.0",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109793280/"
},
{
"category": "vendor_fix",
"details": "SIMATIC S7-1500 CPU family: Update to v2.8.1",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0007"
],
"url": "https://support.industry.siemens.com/cs/document/109478459/"
},
{
"category": "vendor_fix",
"details": "SIMATIC S7-1500 Software Controller: Update to v20.8",
"product_ids": [
"CSAFPID-0004",
"CSAFPID-00013"
],
"url": "https://support.industry.siemens.com/cs/document/109772864/"
},
{
"category": "vendor_fix",
"details": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2: Update to v20.8",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/document/109759122/"
},
{
"category": "mitigation",
"details": "All affected devices contain a feature called \u201cAccess Protection\u201d that prohibits unauthorized modifications of user code. Siemens recommends using access protection to protect affected devices from unauthorized modifications.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "mitigation",
"details": "Locate control system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends users protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to Siemens \u0027 operational guidelines for industrial security, and follow the recommendations in the product manuals. Additional information on industrial security by Siemens can be found at: https://www.siemens.com/industrialsecurity.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.siemens.com/industrialsecurity"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
}
]
},
{
"cve": "CVE-2019-10943",
"cwe": {
"id": "CWE-353",
"name": "Missing Support for Integrity Check"
},
"notes": [
{
"category": "summary",
"text": "An attacker with network access to Port 102/TCP could modify the user program on the PLC in a way that the running code is different from the source code stored on the device. CVE-2019-10943 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-10943"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "SIMATIC S7 PLCSIM Advanced: Update to v3.0",
"product_ids": [
"CSAFPID-0003",
"CSAFPID-00010"
],
"url": "https://support.industry.siemens.com/cs/document/109772889/"
},
{
"category": "vendor_fix",
"details": "SIMATIC S7-1200 CPU family: Update to v4.4.0",
"product_ids": [
"CSAFPID-0005",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109793280/"
},
{
"category": "vendor_fix",
"details": "SIMATIC S7-1500 CPU family: Update to v2.8.1",
"product_ids": [
"CSAFPID-0002",
"CSAFPID-0007"
],
"url": "https://support.industry.siemens.com/cs/document/109478459/"
},
{
"category": "vendor_fix",
"details": "SIMATIC S7-1500 Software Controller: Update to v20.8",
"product_ids": [
"CSAFPID-0004",
"CSAFPID-00013"
],
"url": "https://support.industry.siemens.com/cs/document/109772864/"
},
{
"category": "vendor_fix",
"details": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2: Update to v20.8",
"product_ids": [
"CSAFPID-0006",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00012"
],
"url": "https://support.industry.siemens.com/cs/document/109759122/"
},
{
"category": "mitigation",
"details": "All affected devices contain a feature called \u201cAccess Protection\u201d that prohibits unauthorized modifications of user code. Siemens recommends using access protection to protect affected devices from unauthorized modifications.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "mitigation",
"details": "Locate control system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends users protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends users configure the environment according to Siemens \u0027 operational guidelines for industrial security, and follow the recommendations in the product manuals. Additional information on industrial security by Siemens can be found at: https://www.siemens.com/industrialsecurity.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
],
"url": "https://www.siemens.com/industrialsecurity"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0007",
"CSAFPID-0008",
"CSAFPID-0009",
"CSAFPID-00010",
"CSAFPID-00011",
"CSAFPID-00012",
"CSAFPID-00013"
]
}
]
}
]
}
SSA-232418
Vulnerability from csaf_siemens - Published: 2019-08-13 00:00 - Updated: 2022-08-09 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
|
< V20.8 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
Siemens / SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
|
< V4.4.0 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
Siemens / SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
|
< V2.8.1 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-1500 Software Controller
Siemens / SIMATIC S7-1500 Software Controller
|
< V20.8 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-PLCSIM Advanced
Siemens / SIMATIC S7-PLCSIM Advanced
|
< V3.0 |
Mitigation
Vendor Fix
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC Drive Controller family
Siemens / SIMATIC Drive Controller family
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
|
< V20.8 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
Siemens / SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
|
>= V20.8 |
Mitigation
No Fix Planned
|
|
|
SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
Siemens / SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
|
< V4.4.0 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
Siemens / SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
|
>= V4.4.0 |
Mitigation
No Fix Planned
|
|
|
SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
Siemens / SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
|
< V2.8.1 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
Siemens / SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
|
>= V2.8.1 |
Mitigation
No Fix Planned
|
|
|
SIMATIC S7-1500 Software Controller
Siemens / SIMATIC S7-1500 Software Controller
|
< V20.8 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-1500 Software Controller
Siemens / SIMATIC S7-1500 Software Controller
|
>= V20.8 |
Mitigation
No Fix Planned
|
|
|
SIMATIC S7-PLCSIM Advanced
Siemens / SIMATIC S7-PLCSIM Advanced
|
< V3.0 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-PLCSIM Advanced
Siemens / SIMATIC S7-PLCSIM Advanced
|
>= V3.0 |
Mitigation
No Fix Planned
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Two vulnerabilities have been identified in the SIMATIC\nS7-1200/S7-1500 CPU families and related products. One vulnerability\n(CVE-2019-10943) could allow an attacker with network access to\naffected devices to modify the user program stored on these devices\nsuch that the source code differs from the actual running code. The\nother vulnerability (CVE-2019-10929) could allow an attacker in a Man-\nin-the-Middle position to modify network traffic exchanged on port\n102/tcp. Siemens has released updates for several affected\nproducts to fix CVE-2019-10929 and recommends to update to the latest\nversions. Regarding CVE-2019-10943, Siemens recommends specific\ncountermeasures for products where updates are not, or not yet\navailable.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-232418: Vulnerabilities in SIMATIC S7-1200 and SIMATIC S7-1500 CPU Families - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
},
{
"category": "self",
"summary": "SSA-232418: Vulnerabilities in SIMATIC S7-1200 and SIMATIC S7-1500 CPU Families - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-232418.txt"
},
{
"category": "self",
"summary": "SSA-232418: Vulnerabilities in SIMATIC S7-1200 and SIMATIC S7-1500 CPU Families - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-232418.json"
}
],
"title": "SSA-232418: Vulnerabilities in SIMATIC S7-1200 and SIMATIC S7-1500 CPU Families",
"tracking": {
"current_release_date": "2022-08-09T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-232418",
"initial_release_date": "2019-08-13T00:00:00Z",
"revision_history": [
{
"date": "2019-08-13T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2019-12-10T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added solution for CVE-2019-10929 for S7-1200 and S7-1500. SIPLUS devices now explicitly mentioned in the list of affected products"
},
{
"date": "2020-03-10T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Removed exclusion of SIMATIC S7-1500 CPU 1518-4 PN/DP. Added solution for CVE-2019-10929 for ET200SP CPU 1515SP PC2 and SIMATIC S7-1500 Software Controller"
},
{
"date": "2020-03-12T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Fix information about affected versions in product list."
},
{
"date": "2022-08-09T00:00:00Z",
"legacy_version": "1.4",
"number": "5",
"summary": "Added SIMATIC Drive Controller and SIMATIC ET 200SP Open Controller CPU 1515SP PC as affected products; separate fix information for the different CVE IDs; updated fix release URL for SIMATIC S7-1200; reviewed mitigation measure"
}
],
"status": "final",
"version": "5"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Drive Controller family",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SIMATIC Drive Controller family"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V20.8",
"product": {
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= V20.8",
"product": {
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V4.4.0",
"product": {
"name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= V4.4.0",
"product": {
"name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V2.8.1",
"product": {
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= V2.8.1",
"product": {
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V20.8",
"product": {
"name": "SIMATIC S7-1500 Software Controller",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 Software Controller"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= V20.8",
"product": {
"name": "SIMATIC S7-1500 Software Controller",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 Software Controller"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.0",
"product": {
"name": "SIMATIC S7-PLCSIM Advanced",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-PLCSIM Advanced"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e= V3.0",
"product": {
"name": "SIMATIC S7-PLCSIM Advanced",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-PLCSIM Advanced"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-10929",
"cwe": {
"id": "CWE-327",
"name": "Use of a Broken or Risky Cryptographic Algorithm"
},
"notes": [
{
"category": "summary",
"text": "Affected devices contain a message protection bypass vulnerability due to certain\nproperties in the calculation used for integrity protection.\n\nThis could allow an attacker in a Man-in-the-Middle position to modify network\ntraffic sent on port 102/tcp to the affected devices.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3",
"5",
"7",
"9",
"11"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Apply password protection for S7 communication",
"product_ids": [
"2",
"3",
"5",
"7",
"9",
"11"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V20.8 or later version",
"product_ids": [
"9"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109772864/"
},
{
"category": "vendor_fix",
"details": "Update to V4.4.0 or later version",
"product_ids": [
"5"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109793280/"
},
{
"category": "vendor_fix",
"details": "Update to V3.0 or later version",
"product_ids": [
"11"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109772889/"
},
{
"category": "vendor_fix",
"details": "Update to V2.8.1 or later version",
"product_ids": [
"7"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109478459/"
},
{
"category": "vendor_fix",
"details": "Update to V20.8 or later version",
"product_ids": [
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109759122/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3",
"5",
"7",
"9",
"11"
]
}
],
"title": "CVE-2019-10929"
},
{
"cve": "CVE-2019-10943",
"cwe": {
"id": "CWE-353",
"name": "Missing Support for Integrity Check"
},
"notes": [
{
"category": "summary",
"text": "An attacker with network access to port 102/tcp could potentially modify the\nuser program on the PLC in a way that the running code is different from the\nsource code which is stored on the device.\n\nAn attacker must have network access to affected devices and must be able to\nperform changes to the user program. The vulnerability could impact the\nperceived integrity of the user program stored on the CPU. An engineer that\ntries to obtain the code of the user program running on the device, can\nreceive different source code that is not actually running on the device.\n",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Apply password protection for S7 communication",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"4",
"6",
"8",
"10",
"12"
]
},
{
"category": "vendor_fix",
"details": "Update to V20.8 or later version",
"product_ids": [
"9"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109772864/"
},
{
"category": "vendor_fix",
"details": "Update to V4.4.0 or later version",
"product_ids": [
"5"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109793280/"
},
{
"category": "vendor_fix",
"details": "Update to V3.0 or later version",
"product_ids": [
"11"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109772889/"
},
{
"category": "vendor_fix",
"details": "Update to V2.8.1 or later version",
"product_ids": [
"7"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109478459/"
},
{
"category": "vendor_fix",
"details": "Update to V20.8 or later version",
"product_ids": [
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109759122/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12"
]
}
],
"title": "CVE-2019-10943"
}
]
}
SSA-273799
Vulnerability from csaf_siemens - Published: 2019-12-10 00:00 - Updated: 2022-04-12 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC CP 1626
Siemens / SIMATIC CP 1626
|
6GK1162-6AA01
|
vers:all/* |
No Fix Planned
|
|
SIMATIC HMI Panel (incl. SIPLUS variants)
Siemens / SIMATIC HMI Panel (incl. SIPLUS variants)
|
vers:all/* |
No Fix Planned
|
|
|
SIMATIC NET PC Software V14
Siemens / SIMATIC NET PC Software V14
|
< V14 SP1 Update 14 |
Vendor Fix
fix
|
|
|
SIMATIC NET PC Software V15
Siemens / SIMATIC NET PC Software V15
|
vers:all/* |
No Fix Planned
|
|
|
SIMATIC STEP 7 (TIA Portal)
Siemens / SIMATIC STEP 7 (TIA Portal)
|
< V16 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC (TIA Portal)
Siemens / SIMATIC WinCC (TIA Portal)
|
< V16 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC OA
Siemens / SIMATIC WinCC OA
|
< V3.16 P013 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC Runtime Professional
Siemens / SIMATIC WinCC Runtime Professional
|
< V16 |
Vendor Fix
fix
|
|
|
TIM 1531 IRC (incl. SIPLUS NET variants)
Siemens / TIM 1531 IRC (incl. SIPLUS NET variants)
|
< V2.1 |
Vendor Fix
fix
|
{
"document": {
"acknowledgments": [
{
"names": [
"Eli Biham",
"Sara Bitan",
"Aviad Carmel",
"Alon Dankner"
],
"organization": "Faculty of Computer Science, Technion Haifa",
"summary": "reporting the vulnerabilities"
},
{
"names": [
"Avishai Wool",
"Uriel Malin"
],
"organization": "School of Electrical Engineering, Tel-Aviv University",
"summary": "reporting the vulnerabilities"
}
],
"category": "Siemens Security Advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "A message integrity protection bypass vulnerability has been identified in several SIMATIC products. The vulnerability could allow an attacker in a Man-in-the-Middle position to modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families.\n\nSiemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"category": "self",
"summary": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-273799.txt"
},
{
"category": "self",
"summary": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-273799.json"
}
],
"title": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products",
"tracking": {
"current_release_date": "2022-04-12T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-273799",
"initial_release_date": "2019-12-10T00:00:00Z",
"revision_history": [
{
"date": "2019-12-10T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2020-02-11T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added solution for TIM 1531 IRC and SIMATIC NET PC Software"
},
{
"date": "2020-03-10T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added links for WinCC Runtime"
},
{
"date": "2022-04-12T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added solution for SIMATIC NET PC Software V14 and clarified affected versions; Clarified no remediation planned"
}
],
"status": "final",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC CP 1626",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6GK1162-6AA01"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1626"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI Panel (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V14 SP1 Update 14",
"product": {
"name": "SIMATIC NET PC Software V14",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SIMATIC NET PC Software V14"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC NET PC Software V15",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC NET PC Software V15"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16",
"product": {
"name": "SIMATIC STEP 7 (TIA Portal)",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SIMATIC STEP 7 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16",
"product": {
"name": "SIMATIC WinCC (TIA Portal)",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.16 P013",
"product": {
"name": "SIMATIC WinCC OA",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC OA"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16",
"product": {
"name": "SIMATIC WinCC Runtime Advanced",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Advanced"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16",
"product": {
"name": "SIMATIC WinCC Runtime Professional",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V2.1",
"product": {
"name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "TIM 1531 IRC (incl. SIPLUS NET variants)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-10929",
"cwe": {
"id": "CWE-327",
"name": "Use of a Broken or Risky Cryptographic Algorithm"
},
"notes": [
{
"category": "summary",
"text": "Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection.\n\nThis could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10"
]
},
"references": [
{
"summary": "CVE-2019-10929 - SIMATIC NET PC Software V14",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109807351/"
},
{
"summary": "CVE-2019-10929 - SIMATIC STEP 7 (TIA Portal)",
"url": "https://support.industry.siemens.com/cs/document/109772803/"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC (TIA Portal)",
"url": "https://support.industry.siemens.com/cs/document/109772803/"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC OA",
"url": "https://www.winccoa.com/downloads/category/versions-patches.html"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/document/109771219/"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC Runtime Professional",
"url": "https://support.industry.siemens.com/cs/document/109771219/"
},
{
"summary": "CVE-2019-10929 - TIM 1531 IRC (incl. SIPLUS NET variants)",
"url": "https://support.industry.siemens.com/cs/document/109774204/"
},
{
"summary": "CVE-2019-10929 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-10929.json"
}
],
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"4"
]
},
{
"category": "vendor_fix",
"details": "Update to V14 SP1 Update 14 or later version",
"product_ids": [
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109807351/"
},
{
"category": "vendor_fix",
"details": "Update to version V16",
"product_ids": [
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/document/109772803/"
},
{
"category": "vendor_fix",
"details": "Update to V3.16 P013 or later version",
"product_ids": [
"7"
],
"url": "https://www.winccoa.com/downloads/category/versions-patches.html"
},
{
"category": "vendor_fix",
"details": "Update to version V16",
"product_ids": [
"8",
"9"
],
"url": "https://support.industry.siemens.com/cs/document/109771219/"
},
{
"category": "vendor_fix",
"details": "Update to V2.1",
"product_ids": [
"10"
],
"url": "https://support.industry.siemens.com/cs/document/109774204/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10"
]
}
],
"title": "CVE-2019-10929"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.