CVE-2018-3616 (GCVE-0-2018-3616)

Vulnerability from cvelistv5 – Published: 2018-09-12 19:00 – Updated: 2024-09-16 16:53
VLAI
Summary
Bleichenbacher-style side channel vulnerability in TLS implementation in Intel Active Management Technology before 12.0.5 may allow an unauthenticated user to potentially obtain the TLS session key via the network.
CWE
  • Denial of Service, Information Disclosure
Assigner
intel CNA under the mitre root
CNA scorecard C 60/100 over 96 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Intel Corporation Intel(R) Active Management Technology Affected: Versions before 12.0.5.
guessed Create a notification for this product.
Date Public
2018-09-11 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T04:50:30.382Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
          },
          {
            "name": "106996",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106996"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Intel(R) Active Management Technology",
          "vendor": "Intel Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Versions before 12.0.5."
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Bleichenbacher-style side channel vulnerability in TLS implementation in Intel Active Management Technology before 12.0.5 may allow an unauthenticated user to potentially obtain the TLS session key via the network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Denial of Service, Information Disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-25T22:57:01.000Z",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
        },
        {
          "name": "106996",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106996"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-3616",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Intel(R) Active Management Technology",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions before 12.0.5."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Intel Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Bleichenbacher-style side channel vulnerability in TLS implementation in Intel Active Management Technology before 12.0.5 may allow an unauthenticated user to potentially obtain the TLS session key via the network."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Denial of Service, Information Disclosure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
            },
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html",
              "refsource": "CONFIRM",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
            },
            {
              "name": "106996",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106996"
            },
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20180924-0003/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2018-3616",
    "datePublished": "2018-09-12T19:00:00.000Z",
    "dateReserved": "2017-12-28T00:00:00.000Z",
    "dateUpdated": "2024-09-16T16:53:35.507Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2018-3616",
      "date": "2026-10-21",
      "epss": "0.02388",
      "percentile": "0.838"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C23AFAB4-B286-4FD6-ABC3-86B2881E271C",
                    "versionEndExcluding": "12.0.5",
                    "versionStartIncluding": "11.0.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:intel:active_management_technology_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D5FAD938-027A-406F-9E7C-1BFD992839F4",
                    "versionEndExcluding": "12.0.5",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:intel:manageability_engine_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "63591E72-6038-4417-BA10-54180507AF0F",
                    "versionEndExcluding": "11.0",
                    "versionStartIncluding": "9.0.0.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "503E551C-FC5F-4ABC-8DEA-E360701F0B33",
                    "versionEndExcluding": "22.01.06",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "33F546AF-8F80-4E0A-9B92-86E3A1F931C0",
                    "versionEndExcluding": "21.01.09",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6B5B6E6B-16A0-4236-AABE-82385B53EC78",
                    "versionEndExcluding": "21.01.09",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc547e_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D476D093-4A97-499C-B40D-7A301BC9AA2E",
                    "versionEndExcluding": "r1.30.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_pc547e:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F6A757F1-E478-4A3D-8D5F-C996E176A11A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_pc547g_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "30F129DB-51AC-4F40-A0D1-AB5CF90D9C2D",
                    "versionEndExcluding": "r1.23.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc547g:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9EB339B5-602F-4AB5-9998-465FDC6ABD6C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc627d_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "790D244A-AC3D-4BBC-9139-A90048FD375A",
                    "versionEndExcluding": "19.02.11",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc627d:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "509AD120-3465-4C00-AAB3-B6F6ED708B51",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc647d_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0C046182-BB33-41D0-B041-1566B8041917",
                    "versionEndExcluding": "19.01.14",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc647d:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D0EF28FB-BAB3-4710-9D25-25F67ACADC60",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc677d_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8DE74300-E061-452E-AD1D-6DD7C2C62729",
                    "versionEndExcluding": "19.02.11",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc677d:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "057D9947-CE4A-4B4C-B721-4B29FB71350C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc827d_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BE4A7C13-6F81-4629-9C28-9202028634AE",
                    "versionEndExcluding": "19.02.11",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc827d:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E6D87239-40C1-4038-B734-D77AC4DDD571",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_ipc847d_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "93485235-481B-4BAF-BB7A-81BB5AA1BC53",
                    "versionEndExcluding": "19.01.14",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_ipc847d:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D8F37D88-E086-4060-8420-BD0F8D8FF580",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AD949046-46E5-48C9-883B-92F04926E8BC",
                    "versionEndExcluding": "23.01.04",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Bleichenbacher-style side channel vulnerability in TLS implementation in Intel Active Management Technology before 12.0.5 may allow an unauthenticated user to potentially obtain the TLS session key via the network."
          },
          {
            "lang": "es",
            "value": "Vulnerabilidad de canal lateral estilo Bleichenbacher en la implementaci\u00f3n TLS en Intel Active Management Technology en versiones anteriores a la 12.0.5 podr\u00eda permitir que un usuario sin autenticar obtenga la clave de sesi\u00f3n TLS por red."
          }
        ],
        "id": "CVE-2018-3616",
        "lastModified": "2024-11-21T04:05:46.667",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 8.6,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.2,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2018-09-12T19:29:02.403",
        "references": [
          {
            "source": "secure@intel.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/106996"
          },
          {
            "source": "secure@intel.com",
            "tags": [
              "Patch",
              "Third Party Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
          },
          {
            "source": "secure@intel.com",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
          },
          {
            "source": "secure@intel.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
          },
          {
            "source": "secure@intel.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
          },
          {
            "source": "secure@intel.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/106996"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Third Party Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377318.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-043-05"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20180924-0003/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03876en_us"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00141.html"
          }
        ],
        "sourceIdentifier": "secure@intel.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-noinfo"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.