CVE-2014-5407 (GCVE-0-2014-5407)
Vulnerability from cvelistv5 – Published: 2014-09-15 14:00 – Updated: 2025-11-03 18:52| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | x_refsource_MISC |
| https://github.com/cisagov/CSAF/blob/develop/csaf… | |
| http://www.schneider-electric.com/products/ww/en/… | |
| https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01 | x_refsource_MISCx_transferred |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Schneider Electric | VAMPSET |
Affected:
0 , ≤ 2.2.136
(custom)
Unaffected: 2.2.145 |
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T11:41:49.181Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "VAMPSET",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "2.2.136",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.2.145"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Aivar Liimets of Martem AS"
}
],
"datePublic": "2014-09-11T06:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMultiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.\u003c/p\u003e"
}
],
"value": "Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file."
}
],
"metrics": [
{
"cvssV2_0": {
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:M/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-03T18:52:21.206Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-254-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-254-01.json"
},
{
"url": "http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSchneider Electric released an update for distribution on August 21, \n2014. The VAMPSET setting tool, v.2.2.145 or newer, can be found here:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/\"\u003ehttp://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/\u003c/a\u003e\u003c/p\u003eSchneider Electric recommends that all customers and users install and use VAMPSET v.2.2.145 or newer.\n\n\u003cbr\u003e"
}
],
"value": "Schneider Electric released an update for distribution on August 21, \n2014. The VAMPSET setting tool, v.2.2.145 or newer, can be found here:\n\n\n http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/ \n\nSchneider Electric recommends that all customers and users install and use VAMPSET v.2.2.145 or newer."
}
],
"source": {
"advisory": "ICSA-14-254-01",
"discovery": "EXTERNAL"
},
"title": "Schneider Electric VAMPSET Stack-based Buffer Overflow",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "To protect the computer and configuration files from unauthorized \nescalation of privileges through manipulation, Schneider Electric \nrecommends users employ best IT practices to secure their computers and \nrelay\u2019s configuration files and to use User Access Control (UAC) to \nfurther improve the security of the computer. Additionally, to minimize \nthe risk of attack, users who are not directly using this software on a \nregular basis are strongly encouraged to delete this application from \ntheir computer to reduce the likelihood of attack and to store relay \nconfiguration files in the client\u2019s protected location.\n\n\u003cbr\u003e"
}
],
"value": "To protect the computer and configuration files from unauthorized \nescalation of privileges through manipulation, Schneider Electric \nrecommends users employ best IT practices to secure their computers and \nrelay\u2019s configuration files and to use User Access Control (UAC) to \nfurther improve the security of the computer. Additionally, to minimize \nthe risk of attack, users who are not directly using this software on a \nregular basis are strongly encouraged to delete this application from \ntheir computer to reduce the likelihood of attack and to store relay \nconfiguration files in the client\u2019s protected location."
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5407",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2014-5407",
"datePublished": "2014-09-15T14:00:00.000Z",
"dateReserved": "2014-08-22T00:00:00.000Z",
"dateUpdated": "2025-11-03T18:52:21.206Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2014-5407",
"date": "2026-11-18",
"epss": "0.00371",
"percentile": "0.31622"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:vampset:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B94A6E8-E88D-4165-850A-754573289558",
"versionEndIncluding": "2.2.136",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file."
},
{
"lang": "es",
"value": "M\u00faltiples desbordamientos de buffer basado en pila en Schneider Electric VAMPSET 2.2.136 y anteriores permite a usuarios locales causar una denegaci\u00f3n de servicio (parada de aplicaci\u00f3n) a trav\u00e9s de un (1) fichero de configuraci\u00f3n o (2) fichero de grabaci\u00f3n de disturbio malformados."
}
],
"id": "CVE-2014-5407",
"lastModified": "2026-05-06T22:30:45.220",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:M/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 2.7,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"userInteractionRequired": true
},
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.4,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.4,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
]
},
"published": "2014-09-15T14:55:11.697",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-254-01.json"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-254-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
}
}
}
Solutions
Workarounds
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.