CVE-2014-2355 (GCVE-0-2014-2355)

Vulnerability from cvelistv5 – Published: 2015-01-17 02:00 – Updated: 2025-10-03 17:01
VLAI
Title
GE Proficy HMI/SCADA CIMPLICITY CimView
Summary
The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file.
Severity
No CVSS data available.
CWE
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 337 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
GE Proficy HMI/SCADA–CIMPLICITY Affected: 0 , ≤ 8.2 (custom)
guessed Create a notification for this product.
Date Public
2015-01-13 07:00
Credits
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T10:14:25.389Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-289-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Proficy HMI/SCADA\u2013CIMPLICITY",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Said Arfi"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file.\u003c/p\u003e"
            }
          ],
          "value": "The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "MEDIUM",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.6,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:L/AC:M/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-03T17:01:02.978Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-289-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE recommends that asset owners apply product updates to Proficy \nHMI/SCADA\u2013CIMPLICITY Versions 8.1 and 8.2. The following product updates\n address the memory access violation vulnerability:\u003c/p\u003e\u003cp\u003eProficy HMI/SCADA \u2013 CIMPLICITY 8.1 SIM 29 (DN4219) available at:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://support.ge-ip.com/support/index?page=dwchannel\u0026amp;id=DN4219\"\u003ehttp://support.ge-ip.com/support/index?page=dwchannel\u0026amp;id=DN4219\u003c/a\u003e\u003c/p\u003e\u003cp\u003eProficy HMI/SCADA\u2013CIMPLICITY 8.2 SIM 26 (DN4197) available at:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://support.ge-ip.com/support/index?page=dwchannel\u0026amp;id=DN4197\"\u003ehttp://support.ge-ip.com/support/index?page=dwchannel\u0026amp;id=DN4197\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE recommends that asset owners apply product updates to Proficy \nHMI/SCADA\u2013CIMPLICITY Versions 8.1 and 8.2. The following product updates\n address the memory access violation vulnerability:\n\nProficy HMI/SCADA \u2013 CIMPLICITY 8.1 SIM 29 (DN4219) available at:\u00a0 http://support.ge-ip.com/support/index?page=dwchannel\u0026id=DN4219 \n\nProficy HMI/SCADA\u2013CIMPLICITY 8.2 SIM 26 (DN4197) available at:\u00a0 http://support.ge-ip.com/support/index?page=dwchannel\u0026id=DN4197"
        }
      ],
      "source": {
        "advisory": "ICSA-14-289-02",
        "discovery": "EXTERNAL"
      },
      "title": "GE Proficy HMI/SCADA CIMPLICITY CimView",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIn cases where upgrading is not feasible, GE advises asset owners \nusing CIMPLICITY versions prior to 8.1 to consider using the following \nrecommendations that may mitigate or eliminate the impact of the \nvulnerability:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003eTake steps to properly secure and protect stored CIMPLICITY screen files (.CIM).\u003c/li\u003e\n\u003cli\u003eAvoid using .CIM files received from unknown sources.\u003c/li\u003e\n\u003cli\u003eAvoid sending unprotected .CIM files over unencrypted networks or public Internet.\u003c/li\u003e\n\u003cli\u003eConsider using a strong hashing algorithm to validate integrity of \ncreated .CIM files and ensure they have not been tampered with over \ntime.\u003c/li\u003e\n\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "In cases where upgrading is not feasible, GE advises asset owners \nusing CIMPLICITY versions prior to 8.1 to consider using the following \nrecommendations that may mitigate or eliminate the impact of the \nvulnerability:\n\n\n\n  *  Take steps to properly secure and protect stored CIMPLICITY screen files (.CIM).\n\n  *  Avoid using .CIM files received from unknown sources.\n\n  *  Avoid sending unprotected .CIM files over unencrypted networks or public Internet.\n\n  *  Consider using a strong hashing algorithm to validate integrity of \ncreated .CIM files and ensure they have not been tampered with over \ntime."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-2355",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-289-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-289-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-2355",
    "datePublished": "2015-01-17T02:00:00.000Z",
    "dateReserved": "2014-03-13T00:00:00.000Z",
    "dateUpdated": "2025-10-03T17:01:02.978Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2014-2355",
      "date": "2026-11-16",
      "epss": "0.00645",
      "percentile": "0.51533"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_cimplicity:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "05C547A7-08D0-475E-BD24-57CC3DF2F89E",
                    "versionEndIncluding": "8.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file."
          },
          {
            "lang": "es",
            "value": "Los componentes (1) CimView y (2) CimEdit en GE Proficy HMI/SCADA-CIMPLICITY 8.2 y anteriores permiten a atacantes remotos ganar privilegios a trav\u00e9s de un fichero de pantalla CIMPLICITY manipulado (tambi\u00e9n conocido como .CIM)."
          }
        ],
        "id": "CVE-2014-2355",
        "lastModified": "2026-05-06T22:30:45.220",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.6,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:L/AC:M/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 2.7,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary",
              "userInteractionRequired": true
            },
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.9,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 3.4,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ]
        },
        "published": "2015-01-17T02:59:00.067",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-289-02"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-289-02"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      }
    }
  }
}


Solutions

CNA · icscert
GE recommends that asset owners apply product updates to Proficy HMI/SCADA–CIMPLICITY Versions 8.1 and 8.2. The following product updates address the memory access violation vulnerability: Proficy HMI/SCADA – CIMPLICITY 8.1 SIM 29 (DN4219) available at:  http://support.ge-ip.com/support/index?page=dwchannel&id=DN4219 Proficy HMI/SCADA–CIMPLICITY 8.2 SIM 26 (DN4197) available at:  http://support.ge-ip.com/support/index?page=dwchannel&id=DN4197

Workarounds

CNA · icscert
In cases where upgrading is not feasible, GE advises asset owners using CIMPLICITY versions prior to 8.1 to consider using the following recommendations that may mitigate or eliminate the impact of the vulnerability: * Take steps to properly secure and protect stored CIMPLICITY screen files (.CIM). * Avoid using .CIM files received from unknown sources. * Avoid sending unprotected .CIM files over unencrypted networks or public Internet. * Consider using a strong hashing algorithm to validate integrity of created .CIM files and ensure they have not been tampered with over time.

Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.