CVE-2014-0774 (GCVE-0-2014-0774)

Vulnerability from cvelistv5 – Published: 2014-02-28 02:00 – Updated: 2025-09-24 21:10
VLAI
Title
Schneider Electric OFS Stack Buffer Overflow
Summary
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
Severity
No CVSS data available.
CWE
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 337 records in the last 180 days details
Date Public
2014-02-27 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T09:27:19.467Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-058-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01"
          },
          {
            "name": "65871",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/65871"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "TLXCDSUOFS33",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V3.35"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TLXCDSTOFS33",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V3.35"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TLXCDLUOFS33",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V3.35"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TLXCDLTOFS33",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V3.35"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TLXCDLFOFS33",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V3.35"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Schneider Electric"
        }
      ],
      "datePublic": "2014-02-27T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eStack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.\u003c/p\u003e"
            }
          ],
          "value": "Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-24T21:10:10.144Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-058-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01"
        },
        {
          "name": "65871",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/65871"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSchneider Electric has a product upgrade as well as a workaround \nsolution \nthat mitigates this \nvulnerability.\u0026nbsp;\u003c/p\u003e\u003cp\u003eSchneider Electric Security Notification SEVD \n2014-031-01,\u201dVulnerability Disclosure \u2013 OPC Factory Server V3.35,\u201d \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.downloads.schneider-electric.com/?p_Conf=\u0026amp;p_localesFilter=\u0026amp;p_docTypeFilter=1555899,\u0026amp;p_docTypeGroupFilter=3541958\"\u003ehttp://www.downloads.schneider-electric.com/?p_Conf=\u0026amp;p_localesFilter=\u0026amp;p_docTypeFilter=155589...\u003c/a\u003e\u0026nbsp; \u0026nbsp;\u003c/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe security announcements affecting the OPC Factory Server are available here:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page\"\u003ehttp://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page\u003c/a\u003e\u003c/p\u003e\u003c/div\u003eSchneider\n Electric recommends customers to upgrade to OFS v3.4 or later (Version \nv3.5 is currently available). Customers that cannot upgrade are directed\n to remove the demonstration client from affected computers, provided it\n is not required for operations.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Schneider Electric has a product upgrade as well as a workaround \nsolution \nthat mitigates this \nvulnerability.\u00a0\n\nSchneider Electric Security Notification SEVD \n2014-031-01,\u201dVulnerability Disclosure \u2013 OPC Factory Server V3.35,\u201d \n http://www.downloads.schneider-electric.com/?p_Conf=\u0026p_localesFilter=\u0026p_docTypeFilter=155589... http://www.downloads.schneider-electric.com/ \u00a0 \u00a0\n\n\n\nThe security announcements affecting the OPC Factory Server are available here:\n\n\n http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page \n\n\n\nSchneider\n Electric recommends customers to upgrade to OFS v3.4 or later (Version \nv3.5 is currently available). Customers that cannot upgrade are directed\n to remove the demonstration client from affected computers, provided it\n is not required for operations."
        }
      ],
      "source": {
        "advisory": "ICSA-14-058-02",
        "discovery": "INTERNAL"
      },
      "title": "Schneider Electric OFS Stack Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-0774",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-058-02",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-058-02"
            },
            {
              "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01",
              "refsource": "CONFIRM",
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01"
            },
            {
              "name": "65871",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/65871"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-0774",
    "datePublished": "2014-02-28T02:00:00.000Z",
    "dateReserved": "2014-01-02T00:00:00.000Z",
    "dateUpdated": "2025-09-24T21:10:10.144Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2014-0774",
      "date": "2026-11-17",
      "epss": "0.00467",
      "percentile": "0.41036"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:ofs_test_client_tlxcdlfofs33:3.35:*:*:*:*:*:*:*",
                    "matchCriteriaId": "36AB0685-A0FE-4465-8C9E-7C633AAE0584",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:ofs_test_client_tlxcdltofs33:3.35:*:*:*:*:*:*:*",
                    "matchCriteriaId": "16B1D3C2-7A1B-403F-A2BE-01BAC2C01E74",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:ofs_test_client_tlxcdluofs33:3.35:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6B58EF88-D1BC-4858-A3DA-505D72EE46E3",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:ofs_test_client_tlxcdstofs33:3.35:*:*:*:*:*:*:*",
                    "matchCriteriaId": "06B8043C-3542-4B8F-82BE-E1E8A8E067F3",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:ofs_test_client_tlxcdsuofs33:3.35:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1EF80DC0-7948-4E95-B090-14CC482B9DE5",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:opc_factory_server:3.35:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F8874360-6B9A-40C3-A95F-8FD18F73244D",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file."
          },
          {
            "lang": "es",
            "value": "Desbordamiento de buffer basado en pila en el cliente C++ de ejemplo en Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35 y TLXCDLFOFS33 - 3.35 permite a usuarios locales ganar privilegios a trav\u00e9s de vectores involucrando un archivo de configuraci\u00f3n malformado."
          }
        ],
        "id": "CVE-2014-0774",
        "lastModified": "2026-04-29T01:13:23.040",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.8,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 3.1,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary",
              "userInteractionRequired": true
            },
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 6.9,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 3.4,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ]
        },
        "published": "2014-02-28T06:18:54.277",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "url": "http://www.securityfocus.com/bid/65871"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-058-02"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-058-02"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://www.securityfocus.com/bid/65871"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-121"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-119"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      }
    }
  }
}


Solutions

CNA · icscert
Schneider Electric has a product upgrade as well as a workaround solution that mitigates this vulnerability.  Schneider Electric Security Notification SEVD 2014-031-01,”Vulnerability Disclosure – OPC Factory Server V3.35,” http://www.downloads.schneider-electric.com/?p_Conf=&p_localesFilter=&p_docTypeFilter=155589... http://www.downloads.schneider-electric.com/     The security announcements affecting the OPC Factory Server are available here: http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page Schneider Electric recommends customers to upgrade to OFS v3.4 or later (Version v3.5 is currently available). Customers that cannot upgrade are directed to remove the demonstration client from affected computers, provided it is not required for operations.

Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.