CERTFR-2020-AVI-132
Vulnerability from certfr_avis - Published: 2020-03-10 - Updated: 2020-03-10
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SiNVR 3 Central Control Server (CCS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK 840D",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Spectrum Power 5 versions ant\u00e9rieures \u00e0 v5.50 HF02",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiNVR 3 Video Server",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 versions ant\u00e9rieures \u00e0 V3.X.17",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-19290",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19290"
},
{
"name": "CVE-2019-18336",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18336"
},
{
"name": "CVE-2020-7579",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7579"
},
{
"name": "CVE-2019-19292",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19292"
},
{
"name": "CVE-2019-19299",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19299"
},
{
"name": "CVE-2019-19295",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19295"
},
{
"name": "CVE-2019-19294",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19294"
},
{
"name": "CVE-2019-19298",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19298"
},
{
"name": "CVE-2019-19291",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19291"
},
{
"name": "CVE-2019-19293",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19293"
},
{
"name": "CVE-2019-19297",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19297"
},
{
"name": "CVE-2019-19296",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19296"
}
],
"initial_release_date": "2020-03-10T00:00:00",
"last_revision_date": "2020-03-10T00:00:00",
"links": [
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-508982 du 10 mars 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-844761 du 10 mars 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-938930 du 10 mars 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938930.pdf"
}
],
"reference": "CERTFR-2020-AVI-132",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-03-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 SIemens ssa-508982 du 10 mars 2020",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 SIemens ssa-844761 du 10 mars 2020",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 SIemens ssa-938930 du 10 mars 2020",
"url": null
}
]
}
CVE-2019-18336 (GCVE-0-2019-18336)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2026-06-02 18:36- CWE-400 - Uncontrolled Resource Consumption
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) |
Affected:
All versions < V3.X.17
|
|
| Siemens AG | SIMATIC TDC CP51M1 |
Affected:
All versions < V1.1.8
|
|
| Siemens AG | SIMATIC TDC CPU555 |
Affected:
All versions < V1.1.1
|
|
| Siemens AG | SINUMERIK 840D sl |
Affected:
All versions < V4.8.6
|
|
| Siemens AG | SINUMERIK 840D sl |
Affected:
All versions < V4.94
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:54:14.382Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-18336",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T18:35:38.583256Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T18:36:21.590Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.X.17"
}
]
},
{
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.8"
}
]
},
{
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.1"
}
]
},
{
"product": "SINUMERIK 840D sl",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8.6"
}
]
},
{
"product": "SINUMERIK 840D sl",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.94"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V3.X.17), SIMATIC TDC CP51M1 (All versions \u003c V1.1.8), SIMATIC TDC CPU555 (All versions \u003c V1.1.1), SINUMERIK 840D sl (All versions \u003c V4.8.6), SINUMERIK 840D sl (All versions \u003c V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-14T13:18:04.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-18336",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.X.17"
}
]
}
},
{
"product_name": "SIMATIC TDC CP51M1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V1.1.8"
}
]
}
},
{
"product_name": "SIMATIC TDC CPU555",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V1.1.1"
}
]
}
},
{
"product_name": "SINUMERIK 840D sl",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.8.6"
}
]
}
},
{
"product_name": "SINUMERIK 840D sl",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.94"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V3.X.17), SIMATIC TDC CP51M1 (All versions \u003c V1.1.8), SIMATIC TDC CPU555 (All versions \u003c V1.1.1), SINUMERIK 840D sl (All versions \u003c V4.8.6), SINUMERIK 840D sl (All versions \u003c V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-18336",
"datePublished": "2020-03-10T19:16:17.000Z",
"dateReserved": "2019-10-23T00:00:00.000Z",
"dateUpdated": "2026-06-02T18:36:21.590Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-19290 (GCVE-0-2019-19290)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-08-05 02:09- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Control Center Server (CCS) |
Affected:
All versions < V1.5.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.684Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Control Center Server (CCS)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The DOWNLOADS section in the web interface of the Control Center\nServer (CCS) contains a path traversal vulnerability\nthat could allow an authenticated remote attacker to access and download\narbitrary files from the server where CCS is installed."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:56:18.279Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19290",
"datePublished": "2020-03-10T19:16:17.000Z",
"dateReserved": "2019-11-26T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:09:39.684Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19291 (GCVE-0-2019-19291)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-08-05 02:09- CWE-313 - Cleartext Storage in a File or on Disk
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Control Center Server (CCS) |
Affected:
All versions < V1.5.0
|
|
| Siemens | SiNVR/SiVMS Video Server |
Affected:
All versions < V5.0.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.700Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Control Center Server (CCS)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SiNVR/SiVMS Video Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0), SiNVR/SiVMS Video Server (All versions \u003c V5.0.0). The FTP services of the SiVMS/SiNVR Video Server and the Control Center Server (CCS) maintain\nlog files that store login credentials in cleartext.\nIn configurations where the FTP service is enabled, authenticated remote\nattackers could extract login credentials of other users of the service."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-313",
"description": "CWE-313: Cleartext Storage in a File or on Disk",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:56:19.475Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19291",
"datePublished": "2020-03-10T19:16:17.000Z",
"dateReserved": "2019-11-26T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:09:39.700Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19292 (GCVE-0-2019-19292)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-08-05 02:09- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Control Center Server (CCS) |
Affected:
All versions < V1.5.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.650Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Control Center Server (CCS)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The Control Center Server (CCS) contains an SQL injection\nvulnerability in its XML-based communication protocol as provided by default\non ports 5444/tcp and 5440/tcp.\nAn authenticated remote attacker could exploit this vulnerability to\nread or modify the CCS database and potentially execute administrative\ndatabase operations or operating system commands."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:56:20.710Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19292",
"datePublished": "2020-03-10T19:16:17.000Z",
"dateReserved": "2019-11-26T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:09:39.650Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19293 (GCVE-0-2019-19293)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-08-05 02:09- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Control Center Server (CCS) |
Affected:
All versions < V1.5.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.650Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Control Center Server (CCS)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The web interface of the Control Center Server (CCS) contains a\nreflected Cross-site Scripting (XSS) vulnerability\nthat could allow an unauthenticated remote attacker to steal sensitive data\nor execute administrative actions on behalf of a legitimate administrator\nof the CCS web interface."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:N/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:56:21.904Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19293",
"datePublished": "2020-03-10T19:16:17.000Z",
"dateReserved": "2019-11-26T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:09:39.650Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19294 (GCVE-0-2019-19294)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-08-05 02:09- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Control Center Server (CCS) |
Affected:
All versions < V1.5.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.611Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Control Center Server (CCS)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The web interface of the Control Center Server (CCS) contains\nmultiple stored Cross-site Scripting (XSS) vulnerabilities in several input\nfields.\nThis could allow an authenticated remote attacker to inject malicious\nJavaScript code into the CCS web application that is later executed\nin the browser context of any other user who views the relevant CCS\nweb content."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:N/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:56:23.099Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19294",
"datePublished": "2020-03-10T19:16:17.000Z",
"dateReserved": "2019-11-26T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:09:39.611Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19295 (GCVE-0-2019-19295)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-11-18 17:47- CWE-778 - Insufficient Logging
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Control Center Server (CCS) |
Affected:
All versions < V1.5.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.659Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-19295",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-16T20:19:51.942522Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-18T17:47:21.496Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Control Center Server (CCS)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The Control Center Server (CCS) does not enforce logging of\nsecurity-relevant activities in its XML-based communication protocol\nas provided by default on ports 5444/tcp and 5440/tcp.\nAn authenticated remote attacker could exploit this vulnerability to\nperform covert actions that are not visible in the application log."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-778",
"description": "CWE-778: Insufficient Logging",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:56:24.293Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19295",
"datePublished": "2020-03-10T19:16:17.000Z",
"dateReserved": "2019-11-26T00:00:00.000Z",
"dateUpdated": "2024-11-18T17:47:21.496Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19296 (GCVE-0-2019-19296)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-08-05 02:09- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SiNVR/SiVMS Video Server |
Affected:
All versions < V5.0.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.625Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SiNVR/SiVMS Video Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions \u003c V5.0.0). The two FTP services (default ports 21/tcp and 5411/tcp) of the SiVMS/SiNVR Video\nServer contain a path traversal vulnerability\nthat could allow an authenticated remote attacker to access and download\narbitrary files from the server, if the FTP services are enabled."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:56:25.518Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19296",
"datePublished": "2020-03-10T19:16:17.000Z",
"dateReserved": "2019-11-26T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:09:39.625Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19297 (GCVE-0-2019-19297)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-08-05 02:09- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SiNVR/SiVMS Video Server |
Affected:
All versions < V5.0.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.655Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SiNVR/SiVMS Video Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions \u003c V5.0.0). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server\ncontains a path traversal vulnerability, that could allow an\nunauthenticated remote attacker to access and download arbitrary files from the server."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:56:26.734Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19297",
"datePublished": "2020-03-10T19:16:17.000Z",
"dateReserved": "2019-11-26T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:09:39.655Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19298 (GCVE-0-2019-19298)
Vulnerability from cvelistv5 – Published: 2020-03-10 19:16 – Updated: 2024-08-05 02:16- CWE-20 - Improper Input Validation
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SiNVR/SiVMS Video Server |
Affected:
All versions < V5.0.0
|
|
| Siemens | SiNVR/SiVMS Video Server |
Affected:
All versions >= V5.0.0 < V5.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:16:46.883Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SiNVR/SiVMS Video Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.0.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SiNVR/SiVMS Video Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V5.0.0 \u003c V5.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions \u003c V5.0.0), SiNVR/SiVMS Video Server (All versions \u003e= V5.0.0 \u003c V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server\ncontains a input validation vulnerability, that could allow\nan unauthenticated remote attacker to cause a Denial-of-Service condition\nby sending malformed HTTP requests."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:56:27.965Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19298",
"datePublished": "2020-03-10T19:16:17.000Z",
"dateReserved": "2019-11-26T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:16:46.883Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.