Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CERTFR-2019-AVI-207
Vulnerability from certfr_avis - Published: 2019-05-14 - Updated: 2019-05-15
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneImpacted products
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SIMATIC HMI Comfort Panels 4" - 22" versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SIMATIC WinCC (TIA Portal) versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SISHIP IPMS | ||
| Siemens | N/A | SIMATIC PCS 7 | ||
| Siemens | N/A | LOGO! Soft Comfort | ||
| Siemens | N/A | LOGO!8 BM | ||
| Siemens | N/A | SIMATIC HMI KTP Mobile Panels KTP400F,KTP700, KTP700F, KTP900 et KTP900F versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SIMATIC WinCC V7.5 versions antérieures à V7.5 Upd3 | ||
| Siemens | N/A | SIMATIC HMI Classic Devices (TP/MP/OP/MPMobile Panel) | ||
| Siemens | N/A | SINAMICS PERFECT HARMONY GH180 | ||
| Siemens | N/A | SISHIP IMAC | ||
| Siemens | N/A | SISHIP EMCS | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SCALANCE W1750D versions antérieures à V8.4.0.1 | ||
| Siemens | N/A | SIMATIC WinCC Runtime Professional versions antérieures à V15.1 Update 1 |
References
| Title | Publication Time | Tags | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Comfort Panels 4\" - 22\" versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC (TIA Portal) versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SISHIP IPMS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO! Soft Comfort",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO!8 BM",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI KTP Mobile Panels KTP400F,KTP700, KTP700F, KTP900 et KTP900F versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.5 versions ant\u00e9rieures \u00e0 V7.5 Upd3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Classic Devices (TP/MP/OP/MPMobile Panel)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS PERFECT HARMONY GH180",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SISHIP IMAC",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SISHIP EMCS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D versions ant\u00e9rieures \u00e0 V8.4.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Professional versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-7083",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7083"
},
{
"name": "CVE-2019-10919",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10919"
},
{
"name": "CVE-2019-10920",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10920"
},
{
"name": "CVE-2019-6572",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6572"
},
{
"name": "CVE-2018-16417",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-16417"
},
{
"name": "CVE-2018-3991",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3991"
},
{
"name": "CVE-2019-10916",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10916"
},
{
"name": "CVE-2018-3990",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3990"
},
{
"name": "CVE-2018-3989",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3989"
},
{
"name": "CVE-2019-10922",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10922"
},
{
"name": "CVE-2019-10921",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10921"
},
{
"name": "CVE-2019-10924",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10924"
},
{
"name": "CVE-2019-10918",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10918"
},
{
"name": "CVE-2019-10917",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10917"
},
{
"name": "CVE-2018-7064",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7064"
},
{
"name": "CVE-2019-6578",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6578"
},
{
"name": "CVE-2018-7084",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7084"
},
{
"name": "CVE-2019-6576",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6576"
},
{
"name": "CVE-2019-6577",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6577"
},
{
"name": "CVE-2019-6574",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6574"
},
{
"name": "CVE-2018-7082",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7082"
}
],
"initial_release_date": "2019-05-14T00:00:00",
"last_revision_date": "2019-05-15T00:00:00",
"links": [],
"reference": "CERTFR-2019-AVI-207",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-05-14T00:00:00.000000"
},
{
"description": "Ajout de SCADA dans le titre.",
"revision_date": "2019-05-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-705517 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-865156 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865156.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-902727 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-606525 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-606525.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-549547 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-697412 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-804486 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-102144 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-542701 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
}
]
}
CVE-2019-10918 (GCVE-0-2019-10918)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 22:40
VLAI
EPSS
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
- CWE-749 - Exposed Dangerous Method or Function
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.us-cert.gov/ics/advisories/ICSA-19-134-08 | x_refsource_MISC |
Impacted products
14 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SIMATIC PCS 7 V8.0 and earlier |
Affected:
All versions
|
|
| Siemens AG | SIMATIC PCS 7 V8.1 |
Affected:
All versions < V8.1 with WinCC V7.3 Upd 19
|
|
| Siemens AG | SIMATIC PCS 7 V8.2 |
Affected:
All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11
|
|
| Siemens AG | SIMATIC PCS 7 V9.0 |
Affected:
All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) V13 |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) V14 |
Affected:
All versions < V14 SP1 Upd 9
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) V15 |
Affected:
All versions < V15.1 Upd 3
|
|
| Siemens AG | SIMATIC WinCC Runtime Professional V13 |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC Runtime Professional V14 |
Affected:
All versions < V14.1 Upd 8
|
|
| Siemens AG | SIMATIC WinCC Runtime Professional V15 |
Affected:
All versions < V15.1 Upd 3
|
|
| Siemens AG | SIMATIC WinCC V7.2 and earlier |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC V7.3 |
Affected:
All versions < V7.3 Upd 19
|
|
| Siemens AG | SIMATIC WinCC V7.4 |
Affected:
All versions < V7.4 SP1 Upd 11
|
|
| Siemens AG | SIMATIC WinCC V7.5 |
Affected:
All versions < V7.5 Upd 3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.144Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.0 and earlier",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V8.1",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
}
]
},
{
"product": "SIMATIC PCS 7 V8.2",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
}
]
},
{
"product": "SIMATIC PCS 7 V9.0",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V13",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V14",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Upd 9"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal) V15",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd 3"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V13",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V14",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14.1 Upd 8"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional V15",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd 3"
}
]
},
{
"product": "SIMATIC WinCC V7.2 and earlier",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC V7.3",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.3 Upd 19"
}
]
},
{
"product": "SIMATIC WinCC V7.4",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.4 SP1 Upd 11"
}
]
},
{
"product": "SIMATIC WinCC V7.5",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.5 Upd 3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-749",
"description": "CWE-749: Exposed Dangerous Method or Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-23T19:28:42.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10918",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.0 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V8.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V8.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V9.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal) V13",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal) V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1 Upd 9"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal) V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Upd 3"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional V13",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14.1 Upd 8"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Upd 3"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.2 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.3 Upd 19"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.4 SP1 Upd 11"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.5",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.5 Upd 3"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-749: Exposed Dangerous Method or Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10918",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.144Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10919 (GCVE-0-2019-10919)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 22:40
VLAI
EPSS
Summary
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/108382 | vdb-entryx_refsource_BID |
| https://seclists.org/bugtraq/2019/May/73 | mailing-listx_refsource_BUGTRAQ |
| http://seclists.org/fulldisclosure/2019/May/45 | mailing-listx_refsource_FULLDISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| http://packetstormsecurity.com/files/153123/Sieme… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 8 BM (incl. SIPLUS variants) |
Affected:
All versions < V8.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.128Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "108382",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108382"
},
{
"name": "20190529 [SYSS-2019-013]: Siemens LOGO! 8 - Missing Authentication for Critical Function (CWE-306)",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "https://seclists.org/bugtraq/2019/May/73"
},
{
"name": "20190529 [SYSS-2019-013]: Siemens LOGO! 8 - Missing Authentication for Critical Function (CWE-306)",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2019/May/45"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/153123/Siemens-LOGO-8-Missing-Authentication.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "LOGO! 8 BM (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-14T21:05:17.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "108382",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108382"
},
{
"name": "20190529 [SYSS-2019-013]: Siemens LOGO! 8 - Missing Authentication for Critical Function (CWE-306)",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "https://seclists.org/bugtraq/2019/May/73"
},
{
"name": "20190529 [SYSS-2019-013]: Siemens LOGO! 8 - Missing Authentication for Critical Function (CWE-306)",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2019/May/45"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/153123/Siemens-LOGO-8-Missing-Authentication.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10919",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "LOGO! 8 BM (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.3"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "108382",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108382"
},
{
"name": "20190529 [SYSS-2019-013]: Siemens LOGO! 8 - Missing Authentication for Critical Function (CWE-306)",
"refsource": "BUGTRAQ",
"url": "https://seclists.org/bugtraq/2019/May/73"
},
{
"name": "20190529 [SYSS-2019-013]: Siemens LOGO! 8 - Missing Authentication for Critical Function (CWE-306)",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2019/May/45"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
},
{
"name": "http://packetstormsecurity.com/files/153123/Siemens-LOGO-8-Missing-Authentication.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/153123/Siemens-LOGO-8-Missing-Authentication.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10919",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.128Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10920 (GCVE-0-2019-10920)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 22:40
VLAI
EPSS
Summary
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
- CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/108382 | vdb-entryx_refsource_BID |
| https://seclists.org/bugtraq/2019/May/72 | mailing-listx_refsource_BUGTRAQ |
| http://seclists.org/fulldisclosure/2019/May/44 | mailing-listx_refsource_FULLDISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| http://packetstormsecurity.com/files/153122/Sieme… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 8 BM (incl. SIPLUS variants) |
Affected:
All versions < V8.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.342Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "108382",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108382"
},
{
"name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "https://seclists.org/bugtraq/2019/May/72"
},
{
"name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2019/May/44"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/153122/Siemens-LOGO-8-Hard-Coded-Cryptographic-Key.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "LOGO! 8 BM (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-321",
"description": "CWE-321: Use of Hard-coded Cryptographic Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-14T21:05:17.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "108382",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108382"
},
{
"name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "https://seclists.org/bugtraq/2019/May/72"
},
{
"name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2019/May/44"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/153122/Siemens-LOGO-8-Hard-Coded-Cryptographic-Key.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10920",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "LOGO! 8 BM (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.3"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-321: Use of Hard-coded Cryptographic Key"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "108382",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108382"
},
{
"name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
"refsource": "BUGTRAQ",
"url": "https://seclists.org/bugtraq/2019/May/72"
},
{
"name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2019/May/44"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
},
{
"name": "http://packetstormsecurity.com/files/153122/Siemens-LOGO-8-Hard-Coded-Cryptographic-Key.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/153122/Siemens-LOGO-8-Hard-Coded-Cryptographic-Key.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10920",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.342Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10921 (GCVE-0-2019-10921)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 22:40
VLAI
EPSS
Summary
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known
Severity
No CVSS data available.
CWE
- CWE-256 - Unprotected Storage of Credentials
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/108382 | vdb-entryx_refsource_BID |
| https://seclists.org/bugtraq/2019/May/74 | mailing-listx_refsource_BUGTRAQ |
| http://seclists.org/fulldisclosure/2019/May/49 | mailing-listx_refsource_FULLDISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| http://packetstormsecurity.com/files/153124/Sieme… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 8 BM (incl. SIPLUS variants) |
Affected:
All versions < V8.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.264Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "108382",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108382"
},
{
"name": "20190529 [SYSS-2019-014]: Siemens LOGO! 8 - Storing Passwords in a Recoverable Format (CWE-257)",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "https://seclists.org/bugtraq/2019/May/74"
},
{
"name": "20190529 [SYSS-2019-014]: Siemens LOGO! 8 - Storing Passwords in a Recoverable Format (CWE-257)",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2019/May/49"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/153124/Siemens-LOGO-8-Recoverable-Password-Format.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "LOGO! 8 BM (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V8.3). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256: Unprotected Storage of Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-14T21:05:17.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "108382",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108382"
},
{
"name": "20190529 [SYSS-2019-014]: Siemens LOGO! 8 - Storing Passwords in a Recoverable Format (CWE-257)",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "https://seclists.org/bugtraq/2019/May/74"
},
{
"name": "20190529 [SYSS-2019-014]: Siemens LOGO! 8 - Storing Passwords in a Recoverable Format (CWE-257)",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2019/May/49"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/153124/Siemens-LOGO-8-Recoverable-Password-Format.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10921",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "LOGO! 8 BM (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.3"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V8.3). Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-256: Unprotected Storage of Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "108382",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108382"
},
{
"name": "20190529 [SYSS-2019-014]: Siemens LOGO! 8 - Storing Passwords in a Recoverable Format (CWE-257)",
"refsource": "BUGTRAQ",
"url": "https://seclists.org/bugtraq/2019/May/74"
},
{
"name": "20190529 [SYSS-2019-014]: Siemens LOGO! 8 - Storing Passwords in a Recoverable Format (CWE-257)",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2019/May/49"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
},
{
"name": "http://packetstormsecurity.com/files/153124/Siemens-LOGO-8-Recoverable-Password-Format.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/153124/Siemens-LOGO-8-Recoverable-Password-Format.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10921",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.264Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10922 (GCVE-0-2019-10922)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 22:40
VLAI
EPSS
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| http://www.securityfocus.com/bid/108398 | vdb-entryx_refsource_BID |
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SIMATIC PCS 7 V8.0 and earlier |
Affected:
All versions
|
|
| Siemens AG | SIMATIC PCS 7 V8.1 and newer |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC V7.2 and earlier |
Affected:
All versions
|
|
| Siemens AG | SIMATIC WinCC V7.3 and newer |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.230Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
},
{
"name": "108398",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108398"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC PCS 7 V8.0 and earlier",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC PCS 7 V8.1 and newer",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC V7.2 and earlier",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC WinCC V7.3 and newer",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without \"Encrypted Communication\", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-21T17:06:03.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
},
{
"name": "108398",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108398"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10922",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC PCS 7 V8.0 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PCS 7 V8.1 and newer",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.2 and earlier",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinCC V7.3 and newer",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without \"Encrypted Communication\", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
},
{
"name": "108398",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108398"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10922",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10924 (GCVE-0-2019-10924)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 22:40
VLAI
EPSS
Summary
A vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.3). The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated project file. No further privileges are required on the target system. The vulnerability could compromise the confidentiality, integrity and availability of the engineering station. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/108368 | vdb-entryx_refsource_BID |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! Soft Comfort |
Affected:
All versions < V8.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "108368",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108368"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "LOGO! Soft Comfort",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! Soft Comfort (All versions \u003c V8.3). The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated project file. No further privileges are required on the target system. The vulnerability could compromise the confidentiality, integrity and availability of the engineering station. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502: Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-14T21:05:17.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "108368",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108368"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10924",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "LOGO! Soft Comfort",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.3"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in LOGO! Soft Comfort (All versions \u003c V8.3). The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated project file. No further privileges are required on the target system. The vulnerability could compromise the confidentiality, integrity and availability of the engineering station. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-502: Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "108368",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108368"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10924",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6572 (GCVE-0-2019-6572)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 20:23
VLAI
EPSS
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
- CWE-200 - Information Exposure
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| http://www.securityfocus.com/bid/108412 | vdb-entryx_refsource_BID |
| https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SIMATIC HMI Comfort Panels 4" - 22" |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC HMI Comfort Outdoor Panels 7" & 15" |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC WinCC Runtime Advanced |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC WinCC Runtime Professional |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:22.238Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"name": "108412",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108412"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC HMI Comfort Panels 4\" - 22\"",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-24T15:25:12.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"name": "108412",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108412"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-6572",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC HMI Comfort Panels 4\" - 22\"",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200: Information Exposure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"name": "108412",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108412"
},
{
"name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-6572",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-01-22T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:23:22.238Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6574 (GCVE-0-2019-6574)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 20:23
VLAI
EPSS
Summary
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
- CWE-200 - Information Exposure
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- |
Affected:
All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46
|
|
| Siemens AG | SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- |
Affected:
All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:22.234Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865156.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...-",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46"
}
]
},
{
"product": "SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...-",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-14T19:54:48.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865156.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-6574",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...-",
"version": {
"version_data": [
{
"version_value": "All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46"
}
]
}
},
{
"product_name": "SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...-",
"version": {
"version_data": [
{
"version_value": "All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46). An improperly configured Parameter Read/Write execution via Field bus network may cause the controller to restart. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200: Information Exposure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-865156.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865156.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-6574",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-01-22T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:23:22.234Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6576 (GCVE-0-2019-6576)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2026-06-02 18:56
VLAI
EPSS
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-310 - Cryptographic Issues
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| http://www.securityfocus.com/bid/108412 | vdb-entryx_refsource_BID |
| https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SIMATIC HMI Comfort Panels 4" - 22" |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC HMI Comfort Outdoor Panels 7" & 15" |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC WinCC Runtime Advanced |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC WinCC Runtime Professional |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:22.141Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"name": "108412",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108412"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-6576",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T18:53:37.896428Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T18:56:11.669Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC HMI Comfort Panels 4\" - 22\"",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-310",
"description": "CWE-310: Cryptographic Issues",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-24T15:26:04.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"name": "108412",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108412"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-6576",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC HMI Comfort Panels 4\" - 22\"",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-310: Cryptographic Issues"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"name": "108412",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108412"
},
{
"name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-6576",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-01-22T00:00:00.000Z",
"dateUpdated": "2026-06-02T18:56:11.669Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-6577 (GCVE-0-2019-6577)
Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 20:23
VLAI
EPSS
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.
Severity
No CVSS data available.
CWE
- CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| http://www.securityfocus.com/bid/108412 | vdb-entryx_refsource_BID |
| https://www.us-cert.gov/ics/advisories/ICSA-19-134-09 | x_refsource_MISC |
Impacted products
7 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SIMATIC HMI Comfort Panels 4" - 22" |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC HMI Comfort Outdoor Panels 7" & 15" |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC WinCC Runtime Advanced |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC WinCC Runtime Professional |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC WinCC (TIA Portal) |
Affected:
All versions < V15.1 Update 1
|
|
| Siemens AG | SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:22.189Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"name": "108412",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108412"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC HMI Comfort Panels 4\" - 22\"",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC WinCC Runtime Professional",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC WinCC (TIA Portal)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 1"
}
]
},
{
"product": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-80",
"description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-24T15:27:02.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"name": "108412",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108412"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-6577",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC HMI Comfort Panels 4\" - 22\"",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Professional",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC WinCC (TIA Portal)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 1"
}
]
}
},
{
"product_name": "SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"name": "108412",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108412"
},
{
"name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-09"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-6577",
"datePublished": "2019-05-14T19:54:48.000Z",
"dateReserved": "2019-01-22T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:23:22.189Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…