CVE-2026-86151 (GCVE-0-2026-86151)

Vulnerability from cvelistv5 – Published: 2026-09-05 23:45 – Updated: 2026-09-11 20:37
VLAI
Title
Tenda CP3 Network Configuration Management system.c sub_2F77E8 os command injection
Summary
A vulnerability was detected in Tenda CP3 27.5.57.101. The affected element is the function sub_2F77E8 of the file Apis/system.c of the component Network Configuration Management. Performing a manipulation results in os command injection. The attack may be initiated remotely.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-11 20:15 UTC
CWE
References
URL Tags
https://vuldb.com/vuln/399274 vdb-entrytechnical-description
https://vuldb.com/vuln/399274/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-86151 third-party-advisory
https://vuldb.com/submit/895352 third-party-advisory
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version CPE status
Tenda CP3 Affected: 27.5.57.101
    cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-86151",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-11T20:15:50.551027Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-11T20:37:13.261Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Network Configuration Management"
          ],
          "product": "CP3",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "27.5.57.101"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "FengZi (VulDB User)"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "value": "VulDB Vulnerability Moderation Team"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was detected in Tenda CP3 27.5.57.101. The affected element is the function sub_2F77E8 of the file Apis/system.c of the component Network Configuration Management. Performing a manipulation results in os command injection. The attack may be initiated remotely."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 8.3,
            "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-05T23:45:09.354Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-399274 | Tenda CP3 Network Configuration Management system.c sub_2F77E8 os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/399274"
        },
        {
          "name": "VDB-399274 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/399274/cti"
        },
        {
          "name": "CVE-2026-86151 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-86151"
        },
        {
          "name": "Submit #895352 | Tenda CP3 V3.2 V27.5.57.101 OS Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/895352"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-09-05T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-09-05T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-09-05T09:45:52.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda CP3 Network Configuration Management system.c sub_2F77E8 os command injection",
      "x_generator": [
        "VulDB PVTS v202609"
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-86151",
    "datePublished": "2026-09-05T23:45:09.354Z",
    "dateReserved": "2026-09-05T07:40:27.346Z",
    "dateUpdated": "2026-09-11T20:37:13.261Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-86151",
      "date": "2026-09-22",
      "epss": "0.02043",
      "percentile": "0.80314"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*"
                ],
                "modules": [
                  "Network Configuration Management"
                ],
                "product": "CP3",
                "vendor": "Tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "27.5.57.101"
                  }
                ]
              }
            ],
            "source": "cna@vuldb.com"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was detected in Tenda CP3 27.5.57.101. The affected element is the function sub_2F77E8 of the file Apis/system.c of the component Network Configuration Management. Performing a manipulation results in os command injection. The attack may be initiated remotely."
          }
        ],
        "id": "CVE-2026-86151",
        "lastModified": "2026-09-11T21:17:33.980",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "MULTIPLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 8.3,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 6.4,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.3,
              "impactScore": 6.0,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-86151",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-11T20:15:50.551027Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-09-06T00:16:55.773",
        "references": [
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/cve/CVE-2026-86151"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/submit/895352"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/vuln/399274"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/vuln/399274/cti"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://www.tenda.com.cn/"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-77"
              },
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-86151",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-11T20:15:50.551027Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-11T20:15:51.552Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:cp3_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Network Configuration Management"
              ],
              "product": "CP3",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "27.5.57.101"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "FengZi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB Vulnerability Moderation Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda CP3 27.5.57.101. The affected element is the function sub_2F77E8 of the file Apis/system.c of the component Network Configuration Management. Performing a manipulation results in os command injection. The attack may be initiated remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-05T23:45:09.354Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-399274 | Tenda CP3 Network Configuration Management system.c sub_2F77E8 os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/399274"
            },
            {
              "name": "VDB-399274 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/399274/cti"
            },
            {
              "name": "CVE-2026-86151 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-86151"
            },
            {
              "name": "Submit #895352 | Tenda CP3 V3.2 V27.5.57.101 OS Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/895352"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-09-05T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-09-05T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-09-05T09:45:52.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda CP3 Network Configuration Management system.c sub_2F77E8 os command injection",
          "x_generator": [
            "VulDB PVTS v202609"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-86151",
        "datePublished": "2026-09-05T23:45:09.354Z",
        "dateReserved": "2026-09-05T07:40:27.346Z",
        "dateUpdated": "2026-09-11T20:37:13.261Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…