CVE-2026-82793 (GCVE-0-2026-82793)

Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:40
VLAI
Summary
Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 11:39 UTC
CWE
  • CWE-434 - Unrestricted upload of file with dangerous type
Impacted products
Vendor Product Version CPE status
Contec Co., Ltd. CAN-2-WF Affected: 0 , < 2.20 (semver)
guessed Create a notification for this product.
Contec Co., Ltd. CAN-2-USB Affected: 0 , < 2.20 (semver)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-82793",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-14T11:39:25.591689Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-14T11:40:46.929Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CAN-2-WF",
          "vendor": "Contec Co., Ltd.",
          "versions": [
            {
              "lessThan": "2.20",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CAN-2-USB",
          "vendor": "Contec Co., Ltd.",
          "versions": [
            {
              "lessThan": "2.20",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "Unrestricted upload of file with dangerous type",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-14T06:45:52.775Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU90314828/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2026-82793",
    "datePublished": "2026-09-14T06:45:52.775Z",
    "dateReserved": "2026-08-31T02:30:58.279Z",
    "dateUpdated": "2026-09-14T11:40:46.929Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-82793",
      "date": "2026-09-21",
      "epss": "0.00351",
      "percentile": "0.287"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "CAN-2-WF",
                "vendor": "Contec Co., Ltd.",
                "versions": [
                  {
                    "lessThan": "2.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "CAN-2-USB",
                "vendor": "Contec Co., Ltd.",
                "versions": [
                  {
                    "lessThan": "2.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "source": "vultures@jpcert.or.jp"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product."
          }
        ],
        "id": "CVE-2026-82793",
        "lastModified": "2026-09-16T19:27:25.623",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 5.9,
              "source": "vultures@jpcert.or.jp",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "vultures@jpcert.or.jp",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-82793",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-14T11:39:25.591689Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-09-14T07:17:21.480",
        "references": [
          {
            "source": "vultures@jpcert.or.jp",
            "url": "https://jvn.jp/en/vu/JVNVU90314828/"
          },
          {
            "source": "vultures@jpcert.or.jp",
            "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
          }
        ],
        "sourceIdentifier": "vultures@jpcert.or.jp",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-434"
              }
            ],
            "source": "vultures@jpcert.or.jp",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82793",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T11:39:25.591689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T11:39:33.673Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-WF",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-USB",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "Unrestricted upload of file with dangerous type",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:45:52.775Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU90314828/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-82793",
        "datePublished": "2026-09-14T06:45:52.775Z",
        "dateReserved": "2026-08-31T02:30:58.279Z",
        "dateUpdated": "2026-09-14T11:40:46.929Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…