Action not permitted
Modal body text goes here.
Modal Title
Modal Body
JVNDB-2026-032931
Vulnerability from jvndb - Published: 2026-09-14 07:32 - Updated:2026-09-14 07:32
Severity
Summary
Multiple vulnerabilities in Contec PC-HELPER series
Details
PC-HELPER series provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.
- Cross-site scripting (CWE-79) - CVE-2026-82790
- Cross-site request forgery (CWE-352) - CVE-2026-82764
- OS command injection (CWE-78) - CVE-2026-82791
- Cross-site scripting (CWE-79) - CVE-2026-82792
- Unrestricted upload of file with dangerous type (CWE-434) - CVE-2026-82793
References
| Type | URL | |||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
Impacted products
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-032931.html",
"dc:date": "2026-09-14T16:32+09:00",
"dcterms:issued": "2026-09-14T16:32+09:00",
"dcterms:modified": "2026-09-14T16:32+09:00",
"description": "PC-HELPER series provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.\u003ca href=\u0027https://cwe.mitre.org/data/definitions/79.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/352.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/78.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/79.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/434.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003cul\u003e\u003cli\u003eCross-site scripting (CWE-79) - CVE-2026-82790\u003c/li\u003e\u003cli\u003eCross-site request forgery (CWE-352) - CVE-2026-82764\u003c/li\u003e\u003cli\u003eOS command injection (CWE-78) - CVE-2026-82791\u003c/li\u003e\u003cli\u003eCross-site scripting (CWE-79) - CVE-2026-82792\u003c/li\u003e\u003cli\u003eUnrestricted upload of file with dangerous type (CWE-434) - CVE-2026-82793\u003c/li\u003e\u003c/ul\u003eContec Co., Ltd. reported these vulnerabilities to JPCERT/CC to notify users of the solutions through JVN.",
"link": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-032931.html",
"sec:cpe": [
{
"#text": "cpe:/h:contec:can-2-usb",
"@product": "CAN 2.0B Communication Wireless LAN / USB Converter Unit CAN-2-USB",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:can-2-wf",
"@product": "CAN 2.0B Communication Wireless LAN / USB Converter Unit CAN-2-WF",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:dio-0404ry-lwf",
"@product": "PC-HELPER Wireless I/O DIO-0404RY-LWF",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:dio-0404ry-lwf-us",
"@product": "PC-HELPER Wireless I/O DIO-0404RY-LWF-US",
"@vendor": "Contec",
"@version": "2.2"
}
],
"sec:cvss": {
"@score": "5.4",
"@severity": "Medium",
"@type": "Base",
"@vector": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"@version": "3.0"
},
"sec:identifier": "JVNDB-2026-032931",
"sec:references": [
{
"#text": "https://jvn.jp/en/vu/JVNVU90314828/index.html",
"@id": "JVNVU#90314828",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82764",
"@id": "CVE-2026-82764",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82790",
"@id": "CVE-2026-82790",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82791",
"@id": "CVE-2026-82791",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82792",
"@id": "CVE-2026-82792",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82793",
"@id": "CVE-2026-82793",
"@source": "CVE"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-352",
"@title": "Cross-Site Request Forgery(CWE-352)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/434.html",
"@id": "CWE-434",
"@title": "Unrestricted Upload of File with Dangerous Type(CWE-434)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-78",
"@title": "OS Command Injection(CWE-78)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-79",
"@title": "Cross-site Scripting(CWE-79)"
}
],
"title": "Multiple vulnerabilities in Contec PC-HELPER series"
}
CVE-2026-82764 (GCVE-0-2026-82764)
Vulnerability from cvelistv5 – Published: 2026-09-14 06:37 – Updated: 2026-09-14 11:19
VLAI
EPSS
VEX
Summary
Cross-site request forgery vulnerability exists in multiple Contec products. If a user views a specially crafted page while logged in to the affected product, unintended operations may be performed.
Severity
4.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 11:10 UTC
CWE
- CWE-352 - Cross-site request forgery (CSRF)
Assigner
References
Impacted products
33 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | FXA5000 |
Affected:
0 , < 1.12.00
(semver)
|
|
| Contec Co., Ltd. | FXA5020 |
Affected:
0 , < 1.12.00
(semver)
|
|
| Contec Co., Ltd. | FXA5020-[][] |
Affected:
0 , < 1.12.00
(semver)
|
|
| Contec Co., Ltd. | FXE5000 |
Affected:
0 , < 1.12.00
(semver)
|
|
| Contec Co., Ltd. | FXE5000-[][] |
Affected:
0 , < 1.12.00
(semver)
|
|
| Contec Co., Ltd. | FXS5000-[][] |
Affected:
0 , < 1.12.00
(semver)
|
|
| Contec Co., Ltd. | FXS5021 |
Affected:
0 , < 1.12.00
(semver)
|
|
| Contec Co., Ltd. | FXE4000 |
Affected:
0 , < 1.14.00
(semver)
|
|
| Contec Co., Ltd. | FXE4000-WP |
Affected:
0 , < 1.14.00
(semver)
|
|
| Contec Co., Ltd. | FXS4000 |
Affected:
0 , < 1.14.00
(semver)
|
|
| Contec Co., Ltd. | FXS4020 |
Affected:
0 , < 1.14.00
(semver)
|
|
| Contec Co., Ltd. | FXA3000 |
Affected:
0 , < 1.20.00
(semver)
|
|
| Contec Co., Ltd. | FXA3000-[][] |
Affected:
0 , < 1.20.00
(semver)
|
|
| Contec Co., Ltd. | FXA3020 |
Affected:
0 , < 1.20.00
(semver)
|
|
| Contec Co., Ltd. | FXA3020-[][] |
Affected:
0 , < 1.20.00
(semver)
|
|
| Contec Co., Ltd. | FXA3200 |
Affected:
0 , < 1.20.00
(semver)
|
|
| Contec Co., Ltd. | FXE3000 |
Affected:
0 , < 1.20.00
(semver)
|
|
| Contec Co., Ltd. | FXE3000-[][] |
Affected:
0 , < 1.20.00
(semver)
|
|
| Contec Co., Ltd. | FXE3000-WP |
Affected:
0 , < 1.20.00
(semver)
|
|
| Contec Co., Ltd. | FXS300[]-CN |
Affected:
0 , < 1.20.00
(semver)
|
|
| Contec Co., Ltd. | SGA1000 |
Affected:
0 , < 1.02
(semver)
|
|
| Contec Co., Ltd. | RP-WAH-SR1 |
Affected:
0 , < 1.03
(semver)
|
|
| Contec Co., Ltd. | RP-WAH-SR2 |
Affected:
0 , < 1.03
(semver)
|
|
| Contec Co., Ltd. | RP-WAH-SR12 |
Affected:
0 , < 1.02
(semver)
|
|
| Contec Co., Ltd. | RP-WAH-SR22 |
Affected:
0 , < 1.02
(semver)
|
|
| Contec Co., Ltd. | ECE1000 |
Affected:
0 , < 1.02
(semver)
|
|
| Contec Co., Ltd. | ECE1020 |
Affected:
0 , < 1.02
(semver)
|
|
| Contec Co., Ltd. | ECS1020 |
Affected:
0 , < 1.02
(semver)
|
|
| Contec Co., Ltd. | Remote I/O Coupler Unit (Server Type) CPSN-MCB271-* |
Affected:
0 , < 1.82
(semver)
|
|
| Contec Co., Ltd. | Remote I/O Coupler Unit (EtherNet/IP Adapter) CPSN-EOB471EI-[]1 |
Affected:
0 , < 1.02
(semver)
|
|
| Contec Co., Ltd. | Programmable Remote I/O Coupler Unit (Software PLC Type) CPSN-PCB271-S1-041 |
Affected:
0 , < 1.61
(semver)
|
|
| Contec Co., Ltd. | PC-HELPER Wireless I/O DIO-0404RY-LWF |
Affected:
0 , < 1.01.00
(semver)
|
|
| Contec Co., Ltd. | PC-HELPER Wireless I/O DIO-0404RY-LWF-US |
Affected:
0 , < 1.01.00
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82764",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T11:10:02.905024Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T11:19:50.218Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FXA5000",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.12.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXA5020",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.12.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXA5020-[][]",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.12.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXE5000",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.12.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXE5000-[][]",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.12.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXS5000-[][]",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.12.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXS5021",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.12.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXE4000",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.14.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXE4000-WP",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.14.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXS4000",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.14.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXS4020",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.14.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXA3000",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.20.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXA3000-[][]",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.20.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXA3020",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.20.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXA3020-[][]",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.20.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXA3200",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.20.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXE3000",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.20.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXE3000-[][]",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.20.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXE3000-WP",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.20.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FXS300[]-CN",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.20.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SGA1000",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.02",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RP-WAH-SR1",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.03",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RP-WAH-SR2",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.03",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RP-WAH-SR12",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.02",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RP-WAH-SR22",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.02",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ECE1000",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.02",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ECE1020",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.02",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ECS1020",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.02",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote I/O Coupler Unit (Server Type) CPSN-MCB271-*",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.82",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Remote I/O Coupler Unit (EtherNet/IP Adapter) CPSN-EOB471EI-[]1",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.02",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Programmable Remote I/O Coupler Unit (Software PLC Type) CPSN-PCB271-S1-041",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.61",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC-HELPER Wireless I/O DIO-0404RY-LWF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.01.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC-HELPER Wireless I/O DIO-0404RY-LWF-US",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.01.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site request forgery vulnerability exists in multiple Contec products. If a user views a specially crafted page while logged in to the affected product, unintended operations may be performed."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
"version": "3.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "Cross-site request forgery (CSRF)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T09:00:59.406Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_fl_26091000_en.pdf"
},
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_cps_26091000_en.pdf"
},
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU99009004/"
},
{
"url": "https://jvn.jp/en/vu/JVNVU96551518/"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82764",
"datePublished": "2026-09-14T06:37:13.065Z",
"dateReserved": "2026-08-31T02:30:58.276Z",
"dateUpdated": "2026-09-14T11:19:50.218Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82790 (GCVE-0-2026-82790)
Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 12:21
VLAI
EPSS
VEX
Summary
Cross-site scripting vulnerability exists in PC-HELPER Wireless I/O DIO-0404RY-LWF and PC-HELPER Wireless I/O DIO-0404RY-LWF-US. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user's web browser.
Severity
5.4 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 12:21 UTC
CWE
- CWE-79 - Cross-site scripting (XSS)
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | PC-HELPER Wireless I/O DIO-0404RY-LWF |
Affected:
0 , < 1.01.00
(semver)
|
|
| Contec Co., Ltd. | PC-HELPER Wireless I/O DIO-0404RY-LWF-US |
Affected:
0 , < 1.01.00
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82790",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T12:21:02.582680Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T12:21:14.527Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PC-HELPER Wireless I/O DIO-0404RY-LWF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.01.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PC-HELPER Wireless I/O DIO-0404RY-LWF-US",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "1.01.00",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting vulnerability exists in PC-HELPER Wireless I/O DIO-0404RY-LWF and PC-HELPER Wireless I/O DIO-0404RY-LWF-US. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user\u0027s web browser."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross-site scripting (XSS)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:45:17.897Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82790",
"datePublished": "2026-09-14T06:45:17.897Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T12:21:14.527Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82791 (GCVE-0-2026-82791)
Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 12:07
VLAI
EPSS
VEX
Summary
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 12:07 UTC
CWE
- CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | CAN-2-WF |
Affected:
0 , < 2.20
(semver)
|
|
| Contec Co., Ltd. | CAN-2-USB |
Affected:
0 , < 2.20
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82791",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T12:07:44.065201Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T12:07:55.617Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CAN-2-WF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CAN-2-USB",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:45:22.083Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82791",
"datePublished": "2026-09-14T06:45:22.083Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T12:07:55.617Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82792 (GCVE-0-2026-82792)
Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:57
VLAI
EPSS
VEX
Summary
Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user's web browser.
Severity
5.2 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 11:57 UTC
CWE
- CWE-79 - Cross-site scripting (XSS)
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | CAN-2-WF |
Affected:
0 , < 2.20
(semver)
|
|
| Contec Co., Ltd. | CAN-2-USB |
Affected:
0 , < 2.20
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82792",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T11:57:40.788477Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T11:57:52.643Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CAN-2-WF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CAN-2-USB",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user\u0027s web browser."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross-site scripting (XSS)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:45:32.630Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82792",
"datePublished": "2026-09-14T06:45:32.630Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T11:57:52.643Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82793 (GCVE-0-2026-82793)
Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:40
VLAI
EPSS
VEX
Summary
Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 11:39 UTC
CWE
- CWE-434 - Unrestricted upload of file with dangerous type
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | CAN-2-WF |
Affected:
0 , < 2.20
(semver)
|
|
| Contec Co., Ltd. | CAN-2-USB |
Affected:
0 , < 2.20
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82793",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T11:39:25.591689Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T11:40:46.929Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CAN-2-WF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CAN-2-USB",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "Unrestricted upload of file with dangerous type",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:45:52.775Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82793",
"datePublished": "2026-09-14T06:45:52.775Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T11:40:46.929Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…